Summary of the content on the page No. 1
Weather Station with Scrolling Message Alerts
Model: BAR933HG / BAR936HG
User Manual
BAR933HG Eng Cover R7 OP 1 8/20/04, 11:03 PM
Black
Summary of the content on the page No. 2
Heat Index ........................................................... 10 Weather Station with Scrolling Talking Clock .......................................................... 10 Message Alerts Enable / Disable Talk Function ............................ 10 Model: BAR933HG / BAR936HG Using the Talk Function ....................................... 10 Talk Volume ......................................................... 10 User Manual Message Display ..............................................
Summary of the content on the page No. 3
PRODUCT OVERVIEW FRONT VIEW 1. LCD display 1 2. MODE: Change settings / display 2 3. MEMORY: View current, maximum and minimum temperature / humidity / UV readings 3 4. HISTORY: View historical barometer / temperature / 7 4 humidity and UV readings 8 5. MESSAGE: View different messages 5 6. SNOOZE / LIGHT: Activate 8-minute snooze or 9 backlight 10 7. SELECT: Switch Areas 6 8. CHANNEL: Switch remote sensor display 11 9. UP: Increase setting / activate radio-controlled clock 10. DOWN: Decrease se
Summary of the content on the page No. 4
11. Low battery icon for UV sensor LCD DISPLAY 12. UV exposure time for user 1 13. User no. (for UV Mode) or hour history for UVI / 2 Barometric pressure reading 5 3 Message Display Area 4 1 2 5 3 6 4 1. Weather Forecast Area: Animated weather forecast 2. Clock / Alarm / Calendar Area: Radio-controlled 1. Message display clock; alarms; calendar 2. CAUTION: Appears when a warning message is 3. UVI / Barometer Area: UV Index and barometric displayed pressure readings 3. TEMPERATURE HISTORY 4. Mess
Summary of the content on the page No. 5
REMOTE SENSOR (RTGR368N) 1. LCD display 2. LED status indicator 3. Ventilation duct 1 4. Fold-out stand 2 3 4 1. Signal reception 1 2. Time 3. Channel number 2 4. Temp / humidity readings 5. Low battery icon 3 6 6. Temp (°C or °F) 4 7. Humidity % 7 5 1. Wall mount 2. EU / UK radio signal format switch 3. SEARCH button 1 RTGR368 N 4. °C / °F button Made in PR C 5. RESET button 3 6. CHANNEL switch (1-5) 4 5 SEARCH C F RESET 12 3 4 5 7. Battery compartment 6 2 EU UK CHANNEL 7 4 BAR933HG Eng R7 OP
Summary of the content on the page No. 6
CHANGE SETTINGS GETTING STARTED 1. Press SELECT to switch between Areas. BATTERIES indicates the selected Area. Batteries are supplied with this product: • Main unit 4 x UM-4 (AAA) 1.5V • Remote unit 2 x UM-3 (AA) 1.5V Insert batteries before first use, matching the polarity as shown in the battery compartment. For best results, install batteries in the remote sensor before the main 2. Most Areas have alternate display options (for unit. Press RESET after each battery change. example, Clock /
Summary of the content on the page No. 7
To fold out the stand: To use the wall mount: CLOCK AND CALENDAR This product tracks the time and date based on radio- controlled signals from the RTGR368N remote sensor, or manual settings that you enter. For best results: RADIO-CONTROLLED CLOCK • Insert the batteries and select the unit, channel, and radio signal format before you mount the sensor. The time and date are automatically updated by radio- controlled clock signals from official time-keeping • Place the sensor out of direct sunlight
Summary of the content on the page No. 8
RF clock enabled: ALARM SOUND The alarms can be set to sound either a beeping alarm or a talking alarm. However, the sound you choose i.e. beeping or talking will apply to both the Daily and Pre-Alarm. The beeping alarm will beep for 2 minutes and get louder and faster during this time. RF clock disabled: The talking alarm will beep 4 times and then tell you the time for 2 minutes in the selected language. NOTE The talking alarm will only sound if the AC adaptor is being used. If the adaptor is
Summary of the content on the page No. 9
ACTIVATE ALARM WEATHER FORECAST Navigate to the Clock Area, then press ALARM / to This product forecasts the next 12 to 24 hours of weather switch to Daily Alarm or Pre-Alarm view. To activate or within a 30-50 km (19-31 mile) radius. The forecast is deactivate the alarm, press UP or DOWN. based on barometric pressure trend readings. When the alarm time is reached, the backlight will be on for 5 seconds and crescendo alarm will sound for 2 minutes. Press any key (except snooze) to silence the
Summary of the content on the page No. 10
Temperature data is given at the top, humidity is below. NEW ADDITIONAL UV FEATURES UV EXPOSURE TIME COUNTDOWN To set the exposure time countdown you need to set the Skin Type and Sun Protection Factor (SPF) as follows: 1. Press SELECT to navigate to the Barometer Area, then press MODE to select the UV display. SELECT MEASUREMENT UNIT Slide the °C / °F switch (inside the battery compartment), to the setting you want. 2. Press CHANNEL to select user 1-4. 3. Press and hold MODE for 2 seconds to en
Summary of the content on the page No. 11
TEMPERATURE AND HUMIDITY TREND ENABLE / DISABLE TALK FUNCTION The trend lines are shown next to the temperature and To enable or disable the talk function: humidity readings. • Plug or unplug the adaptor. TREND RISING STEADY FALLING OR TEMPERATURE • Press and hold UP and DOWN for 3 seconds. will appear in the bottom, right-hand corner of the HUMIDITY LCD display when the talk function is enabled. NOTE If you are using the adaptor and want to turn the talk function OFF, then press and hold UP a
Summary of the content on the page No. 12
Heat Index Messages: NOTE When you press RESET, all settings will return to default value, and you will lose all stored information. MESSAGE DEFINITION Heat Index N / A Possibility of 26.7°C to 32.2°C / SAFETY AND CARE heat exhaustion 80°F to 90°F Clean the product with a slightly damp cloth and alcohol- Strong heat: Possibility 32.2°C to 40.5°C / free, mild detergent. Avoid dropping the product or of dehydration 90°F to 105°F placing it in a high-traffic location. Very strong heat: Heat 40.5°C
Summary of the content on the page No. 13
Alarm Daily & Pre-Alarm; SPECIFICATIONS 2-minute crescendo Main Unit Dimensions beep or talk alarm L x W x H 295 x 86 x 110 mm Snooze 8-minute snooze (11.61 x 3.39 x 4.33 inches) Weight 386 grams (0.85 lbs) Power without battery Main Unit Remote Unit Dimensions Power adapter 6V AC adapter L x W x H 70 x 24.5 x 116 mm Batteries 4 x UM-4 (AAA) 1.5V (2.76 x 0.96 x 4.57 inches) Weight 114 grams (0.25 lbs) Thermo / Hygro Remote Unit without battery Batteries 2 x UM-3 (AA) 1.5V Temperature Unit °C or
Summary of the content on the page No. 14
EC-DECLARATION OF CONFORMITY This product contains the approved transmitter module that complies with the essential requirements of Article 3 of the R&TTE 1999 / 5 / EC Directive, if used as intended and the following standards have been applied: Safety of information technology equipment (Article 3.1.a of the R&TTE Directive) Applied Standard EN 60950-1 : 2000 Electromagnetic compatibility (Article 3.1.b of the R&TTE Directive) Applied Standards ETSI EN 301 489-1-3 (Ver.1.4.1) : 2002-08 Efficie
Summary of the content on the page No. 15
© 2004 Oregon Scientific. All Rights Reserved. P/N.: 086-003589-019 BAR933HG Eng Back R7 OP 1 8/20/04, 11:03 PM Black