Napoleon Fireplaces B36DFP user manual

User manual for the device Napoleon Fireplaces B36DFP

Device: Napoleon Fireplaces B36DFP
Category: Outdoor Fireplace
Manufacturer: Napoleon Fireplaces
Size: 2.07 MB
Added : 1/27/2014
Number of pages: 30
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Napoleon Fireplaces B36DFP. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Napoleon Fireplaces B36DFP.

For your convenience

If looking through the Napoleon Fireplaces B36DFP user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Napoleon Fireplaces B36DFP on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Napoleon Fireplaces B36DFP to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Napoleon Fireplaces B36DFP User manual - Online PDF
Advertisement
« Page 1 of 30 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Napoleon Fireplaces B36DFP but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Napoleon Fireplaces B36DFP. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

1
W415-0484 / A / 07.26.06
W415-0484 / A / 07.23.06

Summary of the content on the page No. 2

WARNINGS & SAFETY PRECAUTIONS WHAT TO DO IF YOU SMELL GAS

Summary of the content on the page No. 3

TABLE of CONTENTS PG 2-5 INTRODUCTION 19-20 FINISHING Warnings and Safety Precautions Door Removal & Installation Warranty Louvre Installation General Instructions Log Placement / Glowing Embers General Information Charcoal Embers Care of Glass & Plated Parts Charcoal Lumps Logo Placement 6 - 13 VENTING Venting Lengths 21 OPTIONAL BLOWER INSTALLATION Air Terminal Locations 22 OPTIONAL FAN INSTALLATION / Typical Vent Installations GD36 THERMOSTATIC SENSOR Special Vent Installations Venting Specif

Summary of the content on the page No. 4

4 NAPOLEON NAPOLEON NAPOLEON NAPOLEON NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recog- gas fireplaces are manufactured under the strict Standard of the world recog- gas fireplaces are manufactured under the strict Standard of the world recog- gas fireplaces are manufactured under the strict Standard of the world recog- gas fireplaces are manufactured under the strict Standard of the world recog- nized nized nized nized nized ISO 9001 : 2000 Quality Assurance

Summary of the content on the page No. 5

5 Minimum inlet gas supply pressure is 4.5 inches water col- GENERAL INSTRUCTIONS umn for natural gas and 11 inches water column for propane. THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERV- Maximum inlet gas pressure is 7 inches water column for ICED BY A QUALIFIED INSTALLER to conform with local natural gas and 13 inches water column for propane. Mani- codes. In absence of local codes, install the B36DF to the current fold pressure under flow conditions is 3.5 inches water col- National Fuel

Summary of the content on the page No. 6

6 FIGURE 1 VENTING These vent kits allow for either horizontal or vertical venting For safe and proper operation of the fireplace follow the of the fireplace. FIGURES 3 & 5. The maximum allowable venting instruction exactly. horizontal run is 20 feet. The maximum allowable vertical Deviation from the minimum vertical vent length can vent length is 40 feet. The maximum number of 5" vent create difficulty in burner start-up and/or carboning. connections is two horizontally or three vertically (exc

Summary of the content on the page No. 7

7 AIR TERMINAL LOCATIONS FIGURE 2 INSTALLATIONS CANADIAN U.S.A. A 12 INCHES 12 INCHES Clearance above grade, veranda porch, deck or balcony. Clearance to windows or doors that open. B 12 INCHES 9 INCHES Clearance to permanently closed windows. C 12 INCHES* 12 INCHES* Vertical clearance to ventilated soffit located above the terminal within D 18 INCHES** 18 INCHES** a horizontal distance of 2 feet from the centerline of the terminal. E 12 INCHES** 12 INCHES** Clearance to unventilated soffit. 0 I

Summary of the content on the page No. 8

8 TYPICAL VENT INSTALLATIONS NOTE: When terminating vertically, the restrictor plate W500-0205 must be installed. Refer to Restricting Vertical Vents. FIGURES 3 a-c * When installing with no vertical rise, ensure that the vent pipe does not slope downward. SPECIAL VENT INSTALLATIONS PERISCOPE TERMINATION Use the GD401 periscope kit to locate the air termination above grade. The periscope must be installed so that when final grading is completed, the bottom air slot is located a minimum of 12 inc

Summary of the content on the page No. 9

9 VENTING APPLICATION FLOW CHART HORIZONTAL VERTICAL TERMINATION TERMINATION Vertical rise Vertical rise Vertical rise Vertical rise is less than is less than is equal to or is equal to or horizontal horizontal greater greater run run than the than the horizontal horizontal run run Horizontal Horizontal Horizontal Horizontal run + verti- run + verti- run + verti- run + verti- cal rise to cal rise to cal rise to cal rise to maximum maximum maximum maximum of 40 feet of 24.75 feet of 40 feet of 40

Summary of the content on the page No. 10

10 DEFINITIONS ELBOW VENT LENGTH VALUES for the following symbols used in the venting calcula- feet inches tions and examples are: 1° 0.03 0.5 > - greater than 15° 0.45 6.0 > - equal to or greater than 30° 0.9 11.0 < - less than 45°* * * 1.35 16.0 * * < - equal to or less than 90°* * * * * 2.7 32.0 H - total of both horizontal vent lengths (H ) and off- T R sets (H ) in feet O * * * the first 45º and 90° offset has a zero value and is * * H - combined horizontal vent lengths in feet R show

Summary of the content on the page No. 11

11 HORIZONTAL TERMINATION when (H ) > (V ) Example 2: T T Simple venting configuration (only one 45º and 90° elbow) 90° See graph to determine the re- 90° FIGURE 7 FIGURE 8 quired vertical rise V for the re- H T 4 H quired horizontal run H . 3 T 45° V 2 H 1 H 2 90° V 1 V =4 ft 1 V = 1.5 ft 2 V = V + V = 4 ft + 1.5 ft = 5.5 ft REQUIRED T 1 2 VERTICAL H =2 ft 1 RISE IN H =1 ft 2 INCHES (V ) T H =1 ft 3 H = 1.5 ft 4 H = H + H + H + H = 2 + 1 + 1 + 1. 5 = 5.5 ft R 1 2 3 4 H = .03(one 45º elbow + t

Summary of the content on the page No. 12

12 VERTICAL TERMINATION when (H ) < (V ) Example 3: T T Simple venting configurations V FIGURE 9 2 FIGURE10 90° H 90° 2 V 45° 1 45° H 1 90° See graph to determine the required vertical rise V for the T required horizontal run H . T V =5 ft 1 V = 10 ft 2 V =V + V = 5 + 10 = 15 ft T 1 2 H =3 ft 1 H = 2.5 ft 2 REQUIRED VERTICAL RISE IN H =H + H = 3 + 2.5 = 5.5 ft R 1 2 FEET (V ) T H =.03(one 45º elbow + three 90º elbows - 135º) O = .03(45+90+90+90-135)=5.4 H =H + H = 5.5 + 5.4 = 10.9 ft T R O H +

Summary of the content on the page No. 13

13 VERTICAL TERMINATION when (H ) > (V ) V =1 ft T T 1 Simple venting configurations V = 1.5 ft 2 V =V + V = 1 + 1.5 = 2.5 ft T 1 2 H =6 ft FIGURE 11 1 H =2 ft 2 H = H + H = 6 + 2 = 8 ft R 1 2 H = .03(one 45º elbow + three 90º elbow - 135º) O = .03(45 + 90 + 90 + 90 - 135) = 5.4 ft H =H + H = 8 + 5.4 = 13.4 ft T R O H + V = 13.4 + 2.5 = 15.9 ft T T Formula 1: H < 3V T T 3V = 3 x 2.5 = 7.5 ft T 13.4 > 7.5 Since this formula is not met, this vent configuration is unacceptable. Formula 2: H +

Summary of the content on the page No. 14

14 INSTALLATION WALL AND CEILING PROTECTION FOR SAFE AND PROPER OPERATION OF THE FIREPLACE, VERTICAL INSTALLATION FOLLOW THE VENTING INSTRUCTIONS EXACTLY. NOTE: Only a clearance to combustibles of 2" at the This application occurs top of the vent pipe is required and 1" at the bottom FIGURE 16 when venting through a and sides. roof. Installation kits for various roof pitches are HORIZONTAL INSTALLATION available from your Napo- This application occurs when vent leon dealer. See Accesso- ing thro

Summary of the content on the page No. 15

15 USING FLEXIBLE VENT COMPONENTS Use only approved aluminum flexible liner kits marked: For safe and proper operation of the fireplace, follow the vent- ing instructions exactly. All inner exhaust and outer intake vent pipe joints may be sealed using either Red RTV high temp silicone sealant or Black high temp Mill Pac with the exception of the fireplace "Wolf Steel Approved Venting" as exhaust flue collar which must be sealed using Mill Pac identified by the stamp only on the 8” (not supplied

Summary of the content on the page No. 16

16 5. Remove nails from the shingles, above and to the sides RESTRICTING VERTICAL VENTS of the chimney. Place the flashing over the air terminal and Vertical terminations may display a very active flame. As slide it underneath the sides and upper edge of the this appearance is not desirable, the vent exit must be shingles. Ensure that the air terminal is properly centred restricted using restrictor plate, W500-0205. This reduces within the flashing, giving a 3/4" margin all around. Fasten the v

Summary of the content on the page No. 17

17 B36DF MOBILE HOME INSTALLATION FIGURE 27a-d This appliance may be installed as an OEM (Original Equipment Manufacturer) installation in a manufactured home or mobile home and must be installed in accordance with the manufacturer’s instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or the Mobile Home Standard, CAN/CSA Z240 MH Series, in Canada. This appliance is only for use with the type(s) of gas indicated on the rating plat

Summary of the content on the page No. 18

18 FIGURES 32a-c NAILING TAB INSTALLATION CORNER 1) Attach the nailing tabs to the corner POST posts using the 2 sheet metal screws supplied. Secure through the centre of NAILING the top and bottom slots in the nailing TAB tab and then through the existing holes in the corner posts. TOP SLOT NAILING If there are no existing holes, follow TAB these instructions: Position the nailing tab so that the front face is offset with the front edge of the corner post (approx. ½"). Centre the nailing ta

Summary of the content on the page No. 19

19 FINISHING DOOR REMOVAL & INSTALLATION L36 LOUVRE INSTALLATION The upper louvres must be removed to allow the door to be Note: The protective wrap is best removed when the opened or closed. To access the lower door latch, open assembly is at room temperature but this can be improved the valve control door. Release the top and bottom door if the assembly is warmed, using a hair dryer or similar latches, located at the right side of the door. source. FIGURE 35 a-c FIGURE 34 A B C A CLIPS FLANGE

Summary of the content on the page No. 20

20 3. Place the bottom of the left crossover log (#4) onto the LOG PLACEMENT locating stud on the left side of the log support. TM PHAZER logs and glowing embers exclusive to Napoleon Fire- The top of the log should rest in the pocket on the rear log. places, provide a unique and realistic glowing effect that is different in every installation. Take the time to carefully po- sition the glowing embers for a maximum glowing effect. Log colours may vary. During the initial use of the fireplace, the


Alternative user manuals
# User manual Category Download
1 Napoleon Fireplaces B36DFN User manual Outdoor Fireplace 0
2 Napoleon Fireplaces GPFP User manual Outdoor Fireplace 0
3 Napoleon Fireplaces DIRECT VENT MILLIVOLT SYSTEM BGD42P User manual Outdoor Fireplace 1
4 Napoleon Fireplaces GSS36N User manual Outdoor Fireplace 0
5 Napoleon Fireplaces GPFN User manual Outdoor Fireplace 0
6 Napoleon Fireplaces BGD42 User manual Outdoor Fireplace 0
7 Napoleon Fireplaces N415-0232 User manual Outdoor Fireplace 0
8 Napoleon Fireplaces BGP42 User manual Outdoor Fireplace 0
9 Blue Rhino FIREPLACE WAF513C User manual Outdoor Fireplace 0
10 Blue Rhino 255635 User manual Outdoor Fireplace 1
11 Blue Rhino GAD860SP User manual Outdoor Fireplace 3
12 Blue Rhino 252207 User manual Outdoor Fireplace 1
13 Blue Rhino 251828 User manual Outdoor Fireplace 1
14 Blue Rhino FIREPLACE WAF1013C User manual Outdoor Fireplace 1
15 Blue Rhino GAD730T User manual Outdoor Fireplace 0