Modine Manufacturing GAS-FIRED HEATERS BD user manual

User manual for the device Modine Manufacturing GAS-FIRED HEATERS BD

Device: Modine Manufacturing GAS-FIRED HEATERS BD
Category: Gas Heater
Manufacturer: Modine Manufacturing
Size: 3.21 MB
Added : 7/6/2013
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Modine Manufacturing GAS-FIRED HEATERS BD. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Modine Manufacturing GAS-FIRED HEATERS BD.

For your convenience

If looking through the Modine Manufacturing GAS-FIRED HEATERS BD user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Modine Manufacturing GAS-FIRED HEATERS BD on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Modine Manufacturing GAS-FIRED HEATERS BD to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Modine Manufacturing GAS-FIRED HEATERS BD User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Modine Manufacturing GAS-FIRED HEATERS BD but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Modine Manufacturing GAS-FIRED HEATERS BD. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

6-553.3
5H73889A (Rev. D)
April, 2002
INSTALLATION AND SERVICE MANUAL
gas-fired unit heaters
models PD and BD
All models approved for use in California by the CEC (when
equipped with IPI), in New York by the MEA division, and in
Massachusetts. Unit heater is certified for non-residential
applications.
Contents Pages
Inspection on arrival................................................................1
Installation (including venting)..............................................2-8
Operation ..

Summary of the content on the page No. 2

INSTALLATION SPECIAL PRECAUTIONS THE INSTALLATION AND MAINTENANCE INSTRUCTIONS IN THIS 16. Modine unit heaters are designed for use in heating applications MANUAL MUST BE FOLLOWED TO PROVIDE SAFE, EFFICIENT with ambient temperatures between 32° F and 90° F If an AND TROUBLE-FREE OPERATION. IN ADDITION, PARTICULAR application exists where ambient temperatures can be expected to CARE MUST BE EXERCISED REGARDING THE SPECIAL fall outside of this range, contact factory for recommendations. PRECAUTION

Summary of the content on the page No. 3

INSTALLATION In the U.S., the installation of these units must comply with the Combustion Air Requirements “National Fuel Gas Code,” ANSI Z223.1, latest edition (also known Units installed in tightly sealed buildings or confined spaces should as NFPA 54) and other applicable local building codes. be provided with two permanent openings, one near the top of the In Canada, the installation of these units must comply with local enclosure and one near the bottom. Each opening should have a plumbing

Summary of the content on the page No. 4

INSTALLATION The PD 350 and PD 400 have four mounting holes. On all 5. Avoid venting through unheated space when possible. When blower units, except the PD 350 and PD 400, two tapped holes venting does pass through an unheated space, Modine are provided in the top of the unit and two holes in the blower recommends the use of Type B double wall vent. If single support bracket. The PD 350 and PD 400 have four tapped wall vent is used, insulate vent runs greater than 5 feet to holes in the top of t

Summary of the content on the page No. 5

INSTALLATION ADDITIONAL VENTING REQUIREMENTS FOR VENTING 3. After threading and reaming the ends, inspect piping and INTO AN EXISTING MASONRY CHIMNEY OR COMMON remove loose dirt and chips. VENT (CATEGORY I and II UNITS ONLY) 4. Support piping so that no strains are imposed on unit or 1. Do not vent a Category I or II unit into a common vent with controls. mechanical draft systems operating under positive pressure 5. Use two wrenches when connecting piping to unit controls. (Category III or IV un

Summary of the content on the page No. 6

INSTALLATION Table 3 Gas Pipe Capacities In Cu. Ft. per Hour with Pressure Drop pf 0.3 in. W.C. with Specific Gravity 0.60. Length of Diameter of Pipe - Inches Pipe in Ft. 1/2 3/4 1 1 1/4 1 1/2 2 3 4 6 8 15 76 218 440 750 1220 2480 6500 13880 38700 79000 30 73 152 285 590 890 1650 4700 9700 27370 55850 45 44 124 260 435 700 1475 3900 7900 23350 45600 60 50 105 190 400 610 1150 3250 6800 19330 39500 75 97 200 345 545 1120 3000 6000 17310 35300 90 88 160 320 490 930 2600 5400 15800 32250 105 80 16

Summary of the content on the page No. 7

INSTALLATION Dimension “B” Should Never Recommended Installations Be Less than 1/2 of “A” A B C 3" MAX. TURNING VANES 12" 3" MIN. MIN. 12" 3" MIN. B B MIN. 12" A 3" MAX. A A TURNING VANES B 12" MIN. BAFFLE TOP VIEW SIDE VIEW SIDE VIEW D E F 12" 12" MIN. MIN. B B A TURNING A VANES TURNING BAFFLE VANES BAFFLE SIDE VIEW SIDE VIEW TOP VIEW pressure drop of the nozzles can be found footnoted at the Installation of Blower Models (BD UNITS) bottom of page 14. If filters, nozzles or ductwork are to be u

Summary of the content on the page No. 8

INSTALLATION adjustable motor sheave is supplied with these units. If blower To Install (Figure 5) fan speed changes are required, adjust motor sheave as 1. Remove and discard the motor tie down strap and the follows: shipping block beneath the belt tension adjusting screw (Not used on all models.) NOTE: Do not fire unit until blower adjustment has been made Figure 5 or unit may cycle on limit (overheat) control. Blower Model 1. Shut-off power before making blower speed adjustments. Refer to Det

Summary of the content on the page No. 9

OPERATION Figure 7 Correct Pilot Flame CAUTION Start-up and adjustment procedures should be performed by a qualified serviceman. Check the gas inlet pressure at the unit upstream of the combination gas control. The inlet pressure should be 6"-7" W.C. on natural gas or 12"-14" W.C. on propane. If inlet pressure is too high, install an additional pressure regulator upstream of the combination gas control. The pilot flame must be adjusted as described below. Purging of air from gas lines, piping, a

Summary of the content on the page No. 10

OPERATION Lack of primary air will cause soft yellow-tipped flames. Excess where: primary air produces short, well-defined flames with a tendency F1 = input to heater, Btuh. to lift off the burner ports. Proper operation with natural gas F2 = input to heater, cu. ft. per hr. provides a soft blue flame with a well-defined inner core. C = heating value of gas, Btu per cu. ft. To increase primary air, loosen the manifold mounting screws and tap the manifold away from the mixer tubes until yellow- T

Summary of the content on the page No. 11

Table 6 CHECKING INPUT RATE Manifold Pressure & Gas Consumption * Figure 9 Natural Propane BTU/Cu. Ft. 1050 2500 No. of Major Gas and Electric Components Model Specific Gravity 0.60 1.53 Orifices FAN MOTOR Manifold Pressure In. W.C. 3.5 10.0 FAN GUARD CFH 28.6 12.0 Gal/Hr. Propane – .33 PILOT TUBING PD 30 Sec/cu. ft. 126 300 1 Orifice Drill Size 38 52 CFH 47.6 20.0 PD 50 Gal/Hr. Propane – .55 BD 50 Sec/cu. ft. 76 180 1 Orifice Drill Size 30 45 CFH 71.4 30.0 COMBINATION PD 75 Gal/Hr. Propane – .8

Summary of the content on the page No. 12

DIMENSIONS/PERFORMANCE – PD A C H F K W X K J VENT PIPE G AA For clearance to combustibles, see page 3. B E BB EE LL D (OPENING) L - Approx MIN. DISTANCE L TO WALL IS L + 6" (MIN. DISTANCE TO WALL) Dimensions (inches) — PD Do not use propeller units with duct work. Dimension Model Number Symbol PD 30 PD 50 PD 75 PD 100 PD 125 PD 150 PD 175 PD 200 PD 250 PD 300 PD 350 PD 400 A 12-7/8 17-1/4 17-1/4 19-1/4 19-1/4 21 23-1/2 25-5/8 25-5/8 28-5/8 33-5/8 40 B 24-1/4 24-1/4 28-3/4 28-3/4 35-1/4 35-1/4 3

Summary of the content on the page No. 13

DIMENSIONS/PERFORMANCE – BD C A F N EE H W X P 4-5/8'' K S J VENT PIPE G O AA For clearance to combustibles, see page 3. K QxV E B RxT BB BLOWER FILTER RACK ENCLOSURE M (APPROX.) (OPTIONAL) D (OPENING) (OPTIONAL) L (MIN. DISTANCE TO WALL) Dimensions (inches) — BD Model Number Dimension Symbol BD 50 BD 75 BD 100 BD 125 BD 150 BD 175 BD 200 BD 250 BD 300 BD 350 BD 400 A 17-1/4 17-1/4 19-1/4 19-1/4 21 23-1/2 25-5/8 25-5/8 28-5/8 33-5/8 40 B 24-1/4 28-3/4 28-3/4 35-1/4 35-1/4 35-1/4 40-1/4 40-1/4 40

Summary of the content on the page No. 14

PERFORMANCE DATA – NOZZLES A choice of four air discharge nozzles 90° VERTICAL accommodate various heat throw NOZZLE patterns illustrated. Equipped with adjustable louver blades, nozzles are fabricated from galvanized steel and are offered either unpainted or painted to match the finish of the blower unit heaters. Nozzles are flanged for easy attachment over the air discharge opening of the H blower unit heater. H T S S S 40° DOWNWARD NOZZLE 5-WAY NOZZLES T T H S 40° SPLITTER NOZZLE S S Mounting

Summary of the content on the page No. 15

DIMENSIONAL DATA A A 3 /4" 3 /4" B B D D C C 40° 40° Downward Nozzles Splitter Nozzles A A /4" 3 /4" B B D D C C 90° 5-Way Downward Nozzles Nozzle Dimensions (in inches) Model Number Nozzle Dimension Symbol Type BD 50 BD 75 BD 100 BD 125 BD 150 BD 175 BD 200 BD 250 BD 300 BD 350 BD400 A 14-13/16 14-13/16 16-13/16 16-13/16 18-9/16 21-1/16 23-3/16 23-3/16 26-3/16 31-1/8 37-1/2 40° Downward B 13 16 16 20 20 20 24 24 24 24 24 Nozzle C 20 24 22 26 26 25 30 30 30 36 36 D 3-1/2 4 3 4 4 4 4 4 6 11 11 A

Summary of the content on the page No. 16

PERFORMANCE DATA – HOODS FOR PROPELLER MODELS Performance Data — 30°, 60° and 90° Downward Deflector Hoods Mounting Height to 30° Downward Hood For Propeller Units ➀ Bottom of Heater PD 50 PD 75 PD 100 PD 125 PD 150 PD 175 PD 200 PD 250 PD 300 PD 350 PD 400 Models X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z 8' 8 19 26 11 25 34 14 31 43 15 32 44 16 36 49 18 38 52 15 33 45 21 44 60 24 49 67 22 46 63 22 45 62 10' 6 15 22 9 23 22 13 30 41 14 31

Summary of the content on the page No. 17

PERFORMANCE DATA – HOODS FOR BLOWER MODELS Performance Data — 30°, 60° and 90° Downward Deflector Hoods Mounting Height to 30° Downward Hood For Blower Units ➁ Bottom of Heater BD 50 BD 75 BD 100 BD 125 BD 150 BD 175 BD 200 BD 250 BD 300 BD 350 BD 400 Models X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z X Y Z 8' 13 29 40 18 38 52 22 47 64 23 47 64 26 53 72 28 56 76 24 50 68 31 63 86 35 69 94 37 73 99 30 61 84 10' 12 28 38 16 37 50 21 46 63 21 46 63 25

Summary of the content on the page No. 18

PERFORMANCE DATA - BLOWER UNIT HEATERS Models With or Without Blower Enclosure ➀ ➁ ➂ ➃ ➄ For 575V selections, please see chart on page 19. 0.4 Static Pressure 0.0 Static Air Pressure 0.1 Static Air Pressure 0.2 Static Air Pressure 0.3 Static Air Pressure Sheave Temp Sheave Sheave Sheave Sheave RPM HP Drive Turns Model Rise Airflow RPM HP Drive Turns RPM HP Drive Turns RPM HP Drive Turns RPM HP Drive Turns No. Open No. (°F) (cfm) No. Open No. Open No. Open No. Open 40 926 720 1/4 C183 2 800 1/3 C

Summary of the content on the page No. 19

PERFORMANCE DATA - CONTINUED Models With or Without Blower Enclosure ➀ ➁ ➂ ➃ ➄ Data for use with filters only Filters 0.5 Static Air Pressure 0.6 Static Air Pressure 0.7 Static Air Pressure For blower units with enclosure and filter, add Temp Sheave Sheave Sheave the following static pressures to the static Model Rise Airflow RPM HP Drive Turns RPM HP Drive Turns RPM HP Drive Turns pressure determined by the system designer No. (°F) (cfm) No. Open No. Open No. Open for total external static pres

Summary of the content on the page No. 20

SERVICE INSTRUCTIONS – SAFETY DEVICES (FRONT, TOP VIEW) Figure 13 Service, Safety, and Other Major Unit Heater Components VENT BLOCKED LIMIT CONTROL VENT PIPE VENT SAFETY LOCATED UNDER CONNECTION SWITCH RELIEF LEFT SIDE PANEL OPENING DIMPLED FAN HEAT MOTOR EXCHANGER FOR LOUVERS SERVICE, REMOVE LEFT SIDE PANEL PILOT TUBING TERMINAL BOARD JUNCTION COMBINATION BOX GAS CONTROL COMBUSTION AIR INLETS & BURNER Limit Control (Overheat Switch) the left outer side panel, held in place by screws at the rea


Alternative user manuals
# User manual Category Download
1 Modine Manufacturing BAE User manual Gas Heater 3
2 Modine Manufacturing 6-558.6 User manual Gas Heater 14
3 Modine Manufacturing PAE User manual Gas Heater 33
4 Modine Manufacturing GAS-FIRED HEATERS PD User manual Gas Heater 18
5 Modine Manufacturing GAS-FIRED HEATERS BD User's manual Uncategorized 0
6 Allied Air Enterprises 506271-01 User manual Gas Heater 0
7 Blue Rhino ALL WEATHER WOVEN HEATER GWU9850F / 35554 User manual Gas Heater 2
8 Breckwell ECONOMY P22FSL User manual Gas Heater 0
9 Breckwell ECONOMY P22FSA User manual Gas Heater 0
10 Breckwell ECONOMY P22I User manual Gas Heater 1
11 Briggs & Stratton 32K400 User manual Gas Heater 2
12 Bryan Boilers CLM240WP User manual Gas Heater 2
13 Bryan Boilers CLM180WP User manual Gas Heater 0
14 Bryan Boilers CLM270WP User manual Gas Heater 1
15 Bryan Boilers CLM300WP User manual Gas Heater 0