Miele DAG 1000 user manual

User manual for the device Miele DAG 1000

Device: Miele DAG 1000
Category: Blower
Manufacturer: Miele
Size: 0.49 MB
Added : 10/18/2013
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Miele DAG 1000. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Miele DAG 1000.

For your convenience

If looking through the Miele DAG 1000 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Miele DAG 1000 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Miele DAG 1000 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Miele DAG 1000 User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Miele DAG 1000 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Miele DAG 1000. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Operating and Installation
Instructions
External Blower
DAG 1000
en - US, CA
To prevent accidents
and appliance damage,
read these instructions
before
installation or use. M.-Nr. 07 915 550

Summary of the content on the page No. 2

2

Summary of the content on the page No. 3

Contents IMPORTANT SAFETY INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Functional description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Appliance dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Preparation ............................

Summary of the content on the page No. 4

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE TO REDUCE THE RISK OF INSTRUCTIONS FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, Keep these operating instructions in OBSERVE THE FOLLOWING: a safe place and pass them on to any future user. a) Use this appliance only in the  manner intended by the manufacturer. Read these Instructions carefully If you have questions, contact Miele. before installing or using the b) Before servicing or cleaning the  Ventilation System. appliance, switch

Summary of the content on the page No. 5

IMPORTANT SAFETY INSTRUCTIONS d) Before connecting the appliance Installation  to the power supply make sure that the voltage and frequency listed on the WARNING data plate correspond with the TO REDUCE THE RISK OF household electrical supply. FIRE, ELECTRIC SHOCK, OR This data must correspond to prevent INJURY TO PERSONS, appliance damage. If in doubt consult a qualified electrician. OBSERVE THE FOLLOWING: e) Installation work and repairs a) Installation work and electrical   should only be

Summary of the content on the page No. 6

Functional description The external blower should only be used in combination with Miele ventilation systems DA 6480 or DA 6490. It must be mounted outside the kitchen on an external wall or on the roof. The external blower is connected to the ventilation system by an exhaust duct and power cord. It is operated by means of the ventilation system control panel. The external blower is equipped with a non-return flap so that no exchange of outside air and room air can occur when the ventilation sys

Summary of the content on the page No. 7

Appliance dimensions  Exhaust air connection  Power cord feed-through (strain relief) 7

Summary of the content on the page No. 8

Installation Example: Installation on an external wall Example: Installation on a roof The exhaust connection can be connected to either the front or back of the downdraft. For more information see the installation diagram for the downdraft. 8 dai2749

Summary of the content on the page No. 9

Installation Preparation  Mount the external blower on the external wall using four suitable  Remove all packaging. screws.  Unscrew and remove the six screws  Seal the screw heads. on the blower cover.  Unscrew the two screws on the Installation on a roof terminal box and remove the cover. Select a suitable installation location. Install a UL/CSA-approved cable clamp in the power cord – The angle of the roof must be at least feed-through (strain relief). Locate it 10°. so that it is access

Summary of the content on the page No. 10

Installation  The external blower and the ventilation system are connected by a 10" (254 mm) exhaust duct  (see "Air extraction"). Mount the provided connection plate on the ventilation system (see installation instructions DA 6480, 6490).  Install a UL/CSA-approved power cord (see "Electrical connection"). If unsure or unfamiliar with these installation procedures, please contact a qualified contractor.  Remove the roof shingles at the installation location. Make the cut such that the upper

Summary of the content on the page No. 11

Air extraction Exhaust ducting and connections WARNING – The ducting should be as short and straight as possible, and the number Danger of toxic fumes. of sharp bends should be minimized. Gas cooking appliances release – For most efficient air extraction, the carbon monoxide that can be diameter of the ductwork should not harmful or fatal if inhaled. be less than 10" (254 mm). Use of flat To reduce the risk of fire and to ducts also reduces the air extraction properly exhaust air, the exhaust e

Summary of the content on the page No. 12

Electrical connection WARNING Important : To increase security TO REDUCE THE RISK OF before the machine is installed, it is FIRE, ELECTRIC SHOCK, OR recommended to install a protective INJURY TO PERSONS, switch (30 mA). OBSERVE THE FOLLOWING:  Remove the cover from the external All electrical work should be blower. performed by a qualified electrician  Remove the cover of the terminal in strict accordance with national box. regulations (for USA: ANSI-NFPA 70) and local safety regulations.  I

Summary of the content on the page No. 13

Electrical connection Important Maximum load...............210W The ventilation system must be hard Voltage.....................120V wired as follows: Frequency ..................60Hz Downdraft Circuit Rating .................15A wiring Twist-on connectors Motor wiring GREEN-YELLOW dai2748 Black wire: ....... connect to L1 (live) White wire: ..... connect to N (neutral) Green-yellow wire: . . . connect to GND ......................... (ground)  The remote blower must be connected to the ventila

Summary of the content on the page No. 14

After Sales Service Repairs In the event of a fault which you cannot easily fix yourself, please contact the Miele Technical Service Department.  When contacting the Technical Service Department, please have the model and serial number of your appliance available. These can be found on the data plate located on the housing above the connection box. 14

Summary of the content on the page No. 15

Caring for the environment Disposal of packing material Disposal of an old appliance The cardboard box and packing Old appliances may contain materials materials protect the appliance during that can be recycled. Please contact shipping. They have been designed to your local recycling center about the be biodegradable and recyclable. possibility of recycling these materials. Please recycle. Before discarding an old appliance, DANGER disconnect it from the electrical Ensure that any plastic wrap

Summary of the content on the page No. 16

Alteration rights reserved / 1711 M.-Nr. 07 915 550 / 02 INFORMATION IS SUBJECT TO CHANGE. PLEASE REFER TO OUR WEBSITE TO OBTAIN THE MOST CURRENT PRODUCT SPECIFICATIONS, TECHNICAL & WARRANTY INFORMATION.


Alternative user manuals
# User manual Category Download
1 Miele DAG 1000 User manual Ventilation Hood 0
2 Miele External User manual Blower 3
3 AEG HG654320NM User manual Blower 2
4 Air King Exhaust Fan AK110 User manual Blower 1
5 Air King Exhaust Fan AK50LS User manual Blower 1
6 Air King AK90 User manual Blower 13
7 Air King Exhaust Fan AK110PN User manual Blower 1
8 Air King Exhaust Fan AK80 User manual Blower 1
9 Air King B1125 User manual Blower 1
10 Air King B600 User manual Blower 1
11 Air King 9555 User manual Blower 2
12 Air King AK130 User manual Blower 0
13 Air King Exhaust Fan AK80LS-1 User manual Blower 3
14 Air King B900 User manual Blower 1
15 ATD Tools ATD-31200 User manual Blower 0