LG Electronics SHADOWDANCE LSVFSD-LP user manual

User manual for the device LG Electronics SHADOWDANCE LSVFSD-LP

Device: LG Electronics SHADOWDANCE LSVFSD-LP
Category: Log Splitter
Manufacturer: LG Electronics
Size: 1.95 MB
Added : 2/26/2013
Number of pages: 20
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for LG Electronics SHADOWDANCE LSVFSD-LP. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with LG Electronics SHADOWDANCE LSVFSD-LP.

For your convenience

If looking through the LG Electronics SHADOWDANCE LSVFSD-LP user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual LG Electronics SHADOWDANCE LSVFSD-LP on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual LG Electronics SHADOWDANCE LSVFSD-LP to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
LG Electronics SHADOWDANCE LSVFSD-LP User manual - Online PDF
Advertisement
« Page 1 of 20 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual LG Electronics SHADOWDANCE LSVFSD-LP but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to LG Electronics SHADOWDANCE LSVFSD-LP. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION AND OPERATION INSTRUCTIONS
TM
Vent-Free Millivolt
Dual-Listed Gas Log Sets
Gas Train Models: Log Set Models:
LSVFSD-NG LSVFSD-18 Logs
LSVFSD-LP LSVFSD-24 Logs
Log Sets Sold Separately
P/N 850,051M Rev. A, 08/2007
Installer: Leave This Manual With The Appliance.
Consumer: Retain This Manual For Future Reference.
In the Commonwealth of Massachusetts:
• Installation must be performed by a licensed plumber or gas fitter
US
• See Table of Contents for location of additional
Shado

Summary of the content on the page No. 2

IMPORTANT SAFETY AND WARNING WARNINGS INFORMATION • Allow the appliance to cool before servicing. Always shut off any electricity or gas to the appliance while READ THIS MANUAL IN ITS ENTIRETY AND UNDER- performing service work. STAND THESE RULES TO FOLLOW FOR SAFETY. • The appliance and its individual shut-off valve must be disconnected from the gas supply piping system while WARNINGS performing any tests of the gas supply piping system at If the information in this manual is

Summary of the content on the page No. 3

CONGRATULATIONS ON THE PURCHASE OF YOUR NEW PACKAGING LIST GAS APPLIANCE MANUFACTURED BY LENNOX HEARTH PRODUCTS. the gas train models lsVFsD-Ng and lsVFsD-lP are packaged with the following: When you purchased your new gas-log heaters, you joined the ranks 1 - one base/grate assembly of thousands of individuals whose answer to their home heating needs  - one bag of lava rock reflects their concern for efficiency and our environment. We extend our  - one damper clamp continued support

Summary of the content on the page No. 4

SEE TABLE 3 ON PAGE 16 FOR BTU INPUT AND GAS PRESSURE CODES REQUIREMENTS adhere to all local codes or in their absence the latest edition of the Do not install these Dual-Listed Gas Log Appliances in a bedroom or National Fuel gas code aNsi Z.1 or NFP a 54-latest edition which can a bathroom as all units exceed maximum allowable BTU/hr input of be obtained from the american National standards institute, inc. (140 10,000. Broadway, New York, NY, 10018) or National Fire Protection associ

Summary of the content on the page No. 5

Requirements for the Commonwealth of Massachusetts COMBUSTION AND VENTILATION AIR Note: The following requirements reference various Massachusetts and national codes not contained in this document. t his heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion un-vented r oom Heaters shall be installed in accordance with 5 7 cmr and ventilation air. t he heater may be located in unusually tight construc-  0.00

Summary of the content on the page No. 6

4. compare the maximum Btu/Hr the space can support with the actual Note: Illustrations shown in this manual reflect “typical” installations amount of Btu/Hr used. with nominal dimensions and are for reference only. Actual installations may vary due to individual design preferences. However, always main- _________ Btu/Hr tain minimum clearances to combustible materials and do not violate (max. the space can support) any specific installation requirements. Refer to Figures 2 through 8 for

Summary of the content on the page No. 7

Noncombustible Material Requirements with No Mantel Installed (A) Noncombustible Requirements for Safe Installation Material Measurement 1" or more adjustable canopy not required. 42" 8" minimum to 1" install adjustable canopy. Min. less than 8" extend noncombustible material to at least 8" and install adjustable canopy (Figure 4). 16" or Min. extend noncombustible material to a height of at least 1". Table 1 Noncombustible Material Heights and Mantel Location Figure 2 - Clearances (A) Non

Summary of the content on the page No. 8

Example: The bottom of the mantel may project from the wall a maxi- INSTALLATION mum of 2-1/2" at a minimum of 8" above the opening. The top shelf of the mantel may project a maximum of 6" at a minimum of 14-1/2" above the opening. WARNINGS • Do not use a blower insert, heat exchanger 12" insert or other accessory not approved 10" for use with this heater. 8" • Installed decorative glass door enclosures must be 26" 6" fully opened when operating this dual-listed gas 22-1/2" applia

Summary of the content on the page No. 9

the appliance gas inlet connection is /8"  NPt at the regulator/valve, r eplace the test point plug after pressure measurement ensuring no located on the left side facing the appliance. if a right side connection is gas leaks. required, the connection pipe may be piped under the rear of the appliance to end at the left hand side for connection to the inlet. When tightening up the joint to the regulator hold the regulator securely Step 4. PLACING THE LOGS with a wrench to prevent the regulato

Summary of the content on the page No. 10

LOG PLACEMENT INSTRUCTIONS . Place middle log onto left middle grate locating pin and the rear ember bed locating pin as shown in Figure 13. 1. Place rear ember bed as shown in Figure 11. Middle Log Top Burner Install Ember bed from behind Locating top burner Pins Rear Ember Bed Locating Pins Position Ember Bed All the Way Forward in Gas Train Assembly Figure 11 - Install Rear Ember Bed Figure 13 - Install Middle Log . Place rear log onto the two rear grate locating pins as shown in Figur

Summary of the content on the page No. 11

5. Place left top log onto rear log and middle log locating pins as 8. Place left t op t wig (4" model only) onto corresponding notch shown in Figure 15. on rear log as shown in Figure 18A. the front of the left t op t wig should be up against and behind the left top log. Left Top Log Locating Pins Left Top Log Left Top Twig Figure 15 - Install Left Top Log 6. Place the center top log onto the rear log locating pin and middle log locating pin as shown in Figure 16. Front Ember Bed Center

Summary of the content on the page No. 12

in normal operation, at full rate, after 15 minutes the following flame appearance should be observed: WARNING Failure to position the parts in accordance with Figure Burner And Flame Characteristics 21 or failure to use only parts specifically approved the shadowdance™ gas log set features a new concept in integrated with this appliance may result in property damage or burner and log design. the flames from the burner travel horizontally personal injury. through the log set and em

Summary of the content on the page No. 13

REPLACEMENT PARTS OPERATION AND CARE OF YOUR APPLIANCE an expanded view of the appliance with numbered parts and a parts list can 1. Appliance operation may be controlled through the ON/OFF unit be found on Page 19. all parts should be ordered through your distributor rocker switch, located in the bottom front of the appliance or through or dealer. Parts will be shipped at prevailing prices at time of order. an optional remote control. When ordering repair parts, always give the following

Summary of the content on the page No. 14

Knob Extensions ACCESSORY COMPONENTS Knob extensions for both the on/off and High/low functions are available. Standard Remote Control System (Model RCL) t he model rcl (standard) r emote control system, features a simplistic on/off control function for the fireplace. this model includes a hand-held transmitter, a remote receiver with wall-mount cover plate and all hardware required to install the unit. the remote receiver can be wall or hearth mounted. the transmitter has oN and oFF f

Summary of the content on the page No. 15

Charred Ember Kit ACCESSORY COMPONENTS (CONTINUED) an optional -piece  charred ember Kit is available to enhance the beauty of the log set. Gas Log Sets Left Charred Ember Right Charred Ember 18" Gas Log Set Charred Ember Kit Cat. No. Model No. Description H6894 LSVFSD-CEK Charred Ember Kit Bag of Volcanic Stone Volcanic stone is available for use with these appliances. 24" Gas Log Set Decorative Volcanic Stone Gas Log Sets* Cat. No. Model No. Description Cat. No. Model No. Description 80L42

Summary of the content on the page No. 16

CAUTION: Label all wires prior to disconnection when servicing controls. THERMOPILE Wiring errors can cause improper and dangerous operation. PILOT (O.D.S.) If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105°C – 18 GA. wire. ASSEMBLY MILLIVOLT VALVE WHITE RED WHITE WHITE IGNITION ON/OFF WIRE SWITCH OPTIONAL REMOTE CONTROL PILOT PIEZO (MILLIVOLT) IGNITER Figure 22 - Millivolt Wiring Diagram Vented/Unvented Gas Log Appliance Technical Chart For Milliv

Summary of the content on the page No. 17

O O L I P T O it TPTH TP TH L I P F F LIGHTING INSTRUCTIONS – MILLIVOLT FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. this appliance has a pilot which must be lighted with a piezo • Do not use any phone in your building. igniter. When lighting the pilot, follow these instructions • Immediately call your gas supplier from a neighbor’s exactly. phone. • I

Summary of the content on the page No. 18

VENTED/UNVENTED TROUBLESHOOTING GUIDE OBSERVED PROBLEM POSSIBLE CAUSE REMEDY 1. When igniter button is A. igniter electrode positioned wrong. replace igniter. pressed, there is no spark B. igniter electrode broken. replace igniter. at oDs/pilot. C. igniter electrode not connected to igniter cable. reconnect igniter cable. D. igniter cable pinched or wet. Free igniter cable if pinched by any metal or tubing. Keep igniter cable dry. E. Piezo igniter nut is loose. t ighten nut. F. Broken igniter

Summary of the content on the page No. 19

REPLACEMENT PARTS LIST (MILLIVOLT) - SHADOWDANCE™ SERIES Replacement Parts List (Millivolt) - Shadowdance™ Series, Models LSVFSD-NG and LSVFSD-LP (18" and 24") No. Description Catalog Number 1. Valve, millivolt (Natural) H10 Valve, millivolt (Propane, l.P.g.) H478 2. ember Bed Front H910 3. ember Bed rear H911  4. Bottom Burner H91 5. t op Burner H91   6. Piezo igniter 10K86 7. oDs Pilot assembly, millivolt (Natural) H411 8. oDs Pilot assembly, millivolt (Propane, l.P.g.) H4170 9. K

Summary of the content on the page No. 20

lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. consult your local distributor for fireplace code information. Printed in u.s.a. © 007 by  lennox Hearth Products 1110 West t aft avenue P/N 850,051M REV. A 08/2007 orange, ca 9865 FPO


Alternative user manuals
# User manual Category Download
1 Edelbrock 1553 User manual Log Splitter 0
2 Agri-Fab 25-0126 User manual Log Splitter 1
3 American DJ Splitter User manual Log Splitter 2
4 Ariens 917001 User manual Log Splitter 5
5 Bil-Jax 0108-0104H User manual Log Splitter 0
6 Black Box AC156A-8 User manual Log Splitter 1
7 Black Box AVSP-DVI1X2 User manual Log Splitter 2
8 Black Box AVSP-DVI1X4 User manual Log Splitter 2
9 Black Box AVSP-DVI1X8 User manual Log Splitter 0
10 Black Box CAT5 Audio/Video 8-Port Broadcaster User manual Log Splitter 1
11 Black Box User manual Log Splitter 0
12 Bolens 247-638-000 User manual Log Splitter 0
13 Bolens 24642L User manual Log Splitter 0
14 Bolens 244-645-000 User manual Log Splitter 0
15 Bolens 248-645A User manual Log Splitter 0