Summary of the content on the page No. 1
INSTRUCTIONS AND ADVICE FOR THE
USE, INSTALLATION AND MAINTENANCE
OF MIXED AND GAS FUELLED
BUILT-IN HOT PLATES
Dear Customer,
Thank you for having purchased one of our products.
We are certain that this new, modern, functional and practical appliance, built with the very highest
quality materials, will meet your requirements in the best possible way. This appliance is easy to
use. It is, however, important to thoroughly read the instructions in this handbook in order to obtain
the best results
Summary of the content on the page No. 2
DESCRIPTION OF HOBS TYPES: GMS 6540.0 E - UL TYPES: GMS 9551.0 E - UL 1 Ultra rapid gas burner 11000 Btu/h 2 Rapid gas burner 10000 Btu/h 3 Semirapid gas burner 6100 Btu/h 4 Semirapid gas burner 6100 Btu/h 5 Auxiliary gas burner 3550 Btu/h 6 Enamelled steel pan support 2F 7 Enamelled steel pan support central 8 Burner n° 1 control knob 9 Burner n° 2 control knob 10 Burner n° 3 control knob 11 Burner n° 4 control knob 12 Burner n° 5 control knob 13 Electric ignition button Attention: this applia
Summary of the content on the page No. 3
SAFE GUARD INSTRUCTIONS 1) SAFE GUARD INSTRUCTIONS For all appliances: - the product shall be installed according with the a statement that the installation must conform with local codes or, in absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54. - The product must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70. - The appliance and its individual shutoff valve must be disconnected
Summary of the content on the page No. 4
USE 2) BURNERS Burners Power ratings Pan Ø in cm A diagram is screen-printed above each knob on the front panel. This diagram indicates to which Ultra rapid 11000 Btu/h 24 ÷ 26 burner the knob in question corresponds. After Rapid 10000 Btu/h 20 ÷ 22 having opened the gas mains or gas bottle tap, light the burners as described below: Semirapid 6100 Btu/h 16 ÷ 18 - manual ignition Semirapid 6100 Btu/h 16 ÷ 18 Push and turn the knob corresponding to the required burner in an anticlockwise direction
Summary of the content on the page No. 5
USE Notes: use of a gas cooking appliance produces heat and moisture in the room in which it is installed. The room must therefore be well ventilated. Intensive and lengthy use of the appliance may require additional ventilation. This can be achieved by opening a window or by increasing the power of the mechanical exhausting system if installed. WARNING! NEVER use this appliance as a space heater to heat or warm the room. Doing so may result in carbon monoxide poisoning and overheating ot the ov
Summary of the content on the page No. 6
CLEANING IMPORTANT: WARNINGS: always disconnect the appliance from the gas comply with the following instructions, before and electricity mains before carrying out any remounting the parts: cleaning operation. - check that burner head slots “T” (fig. 3) have not become clogged by foreign bodies. - Check that enamelled burner cap “C” (fig. 3) 3) WORKTOP have correctly positioned on the burner head. Periodically wash the hot plate, the enamelled stell It must be steady. pan support, the enamelled
Summary of the content on the page No. 7
INSTALLATION TECHNICAL INFORMATION 5) FIXING THE HOT PLATE The hot plate has a special seal which prevents FOR THE INSTALLER liquid from getting into the cabinet. Strictly comply Installation, adjustments of controls and with the following instructions in order to correctly maintenance must only be carried out by a apply this seal: qualified engineer. - detach the seals from their backing, checking Incorrect installation may cause damage to that the transparent protection still adheres to the se
Summary of the content on the page No. 8
INSTALLATION The transition piece on the supply side of the 6) ROOM VENTILATION regulator must be provided by the installer. To ensure correct operation of the appliance, it is important to ensure that the room where the hot Unions compatible with the hose fittings must be plate is installed has sufficient ventilation. used and connections tested for gas leaks. Ensure the supply connection point is accessible 7) GAS CONNECTION with the appliance installed. Natural Gas and Propane Gas Warning: en
Summary of the content on the page No. 9
INSTALLATION When the appliance is connected straight to the 8) ELECTRICAL CONNECTION electricity main: The electrical connections of the appliance - install an omnipolar circuit-breaker between the must be carried out in compliance with the appliance and the electricity main. This circuit- provisions and standards in force. breaker should be sized, in compliance with Before connecting the appliance, check that: current installation regulations. - the electrical capacity of the mains supply and
Summary of the content on the page No. 10
INSTALLATION - Fix the hob with the proper brackets “S” and fit the 9) FIXING THE WORKTOP prominent part into the porthole “H” on the bottom; The hot plate has a special seal which prevents turn the screw “F” until the bracket “S” stick on the liquid from infiltrating into the cabinet. Strictly top (fig. 7). comply with the following instructions in order to - The prospective walls (left or right) that exceed the correctly apply this seal: working table in height must be at a minimum - detach th
Summary of the content on the page No. 11
ADJUSTMENTS Always disconnect the appliance from the - Insert a small screwdriver “D” into hole “C” (fig. 9) electricity main before making any adjustments. and turn the throttle screw to the right or left until All seals must be replaced by the technician at the burner flame has been adequately regulated to the end of any adjustments or regulations. the “Reduced rate” position. Our burners do not require primary air Check that the flame does not go out when the adjustment. knob is sharply swit
Summary of the content on the page No. 12
CONVERSIONS paragraphs 10. The technician must reset any 11) REPLACING THE INJECTORS seals on the regulating or pre-regulating devices. The burners can be adapted to different types of The envelope with the injectors and the labels can gas by mounting injectors suited to the type of gas be included in the kit, or at disposal to the in question. To do this, first remove the burner tops authorized customer Service Centre. using a wrench “B”. Now unscrew injector “A” (see For the sake of convenienc
Summary of the content on the page No. 13
SERVICING Always disconnect the appliance from the Greasing the taps (see fig. 15 - 16) electricity and gas mains before proceeding If a tap becomes stiff to operate, it must be with any servicing operation. immediately greased in compliance with the following instructions: 12) REPLACING COMPONENTS - remove the tap. Replacement of the components housed inside - Clean the cone and its housing using a cloth the appliance: remove the trivets and the burners soaked in diluent. from the upper part of
Summary of the content on the page No. 14
TECHNICAL DATA ON THE DATA LABEL 4 BURNERS (60) 5 BURNERS (90) PROPANE HD - 5 = 11 inches water column PROPANE HD - 5 = 11 inches water column NATURAL GAS = 7 inches water column NATURAL GAS = 7 inches water column Σ Qn Natural Gas = 25750 Btu/h Σ Qn Natural Gas = 36750 Btu/h Voltage = 120 V AC Voltage = 120 V AC Frequency = 60 Hz Frequency = 60 Hz 14
Summary of the content on the page No. 15
TECHNICAL DATA FOR THE APPLIANCE GAS REGULATION TECHNICAL ASSISTANCE AND SPARE PARTS Before leaving the factory, this appliance will have been tested and regulated by expert and specialized personnel in order to guarantee the best performances. Any repairs or adjustments which may be subsequently required may only be carried out by qualified personnel with the utmost care and attention. For this reason, always contact your Dealer or our nearest After Sales Service Center whenever repairs or adj
Summary of the content on the page No. 16
Kuppersbusch USA 1883 Massaro Blvd. Tampa, FL 33619 Toll: (800) 459-0844 P: 813-288-8890 F: 813-288-8604