Kohler CFI230G user manual

User manual for the device Kohler CFI230G

Device: Kohler CFI230G
Category: Outdoor Shower
Manufacturer: Kohler
Size: 1.6 MB
Added : 9/4/2013
Number of pages: 14
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Kohler CFI230G. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Kohler CFI230G.

For your convenience

If looking through the Kohler CFI230G user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Kohler CFI230G on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Kohler CFI230G to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Kohler CFI230G User manual - Online PDF
Advertisement
« Page 1 of 14 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Kohler CFI230G but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Kohler CFI230G. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

CFI230G
Indigo Quadrant
Enclosure
with integrated
Mira Magna Shower System
(646)
Slide Rail Fixed Head
Kohler Daryl Limited
Alfred Road, Wallasey, Wirral, CH44 7HY England
Tel 44 (0)151 606 5000 Fax 44 (0)151 638 0303
Fitting Instructions
www.daryl-showers.co.uk
E-mail Daryl@daryl-showers.co.uk
1
1
2
2
3
3
4
4

Summary of the content on the page No. 2

CUSTOMER SERVICE Kohler Daryl and Kohler Mira Daryl Showering have more than 38 years experience of manufacturing and designing shower enclosures of exceptional quality. For over 80 years, Mira Showers have had the same reputation for shower systems. Your new showering product has been created by these two specialist organisations from within the same leading world-wide bathroom company Kohler. They are both bound by the same values of delivering beauty, quality, innovation, reliability and s

Summary of the content on the page No. 3

Indigo Quadrant The Daryl Care Programme Keeping your enclosure beautiful throughout its lifetime is easy with Enclosure products from the Daryl care programme with integrated Using state of the art bespoke machinery combined with the Regular cleaning latest technology, all Daryl doors and panels are coated with Mira Magna Shower System � Mildew thrives in damp, unventilated areas. It is, therefore, a glass protector in highly controlled factory conditions. important to always wipe down,

Summary of the content on the page No. 4

CLEANING COMPONENTS Standard Top Caps Lintel The unit should be cleaned regularly. LH Cap Use a non abrasive cleaner (ideally with a pH value of 4 to 8) applied with a soft cloth. x2 Parking Side Panel Block Under no circumstances should scourers or powerful RH detegents be used as these can damage the metallic surface of the frame and also tarnish the glass coating. Nylon Grub Door Screw x2 To avoid limescale, use your thumb or a soft cloth to wipe any limescale from the soft rubber nozzl

Summary of the content on the page No. 5

TROUBLESHOOTING COMPONENTS Water Delivery The information below gives details on what you can do as a user should you encounter difficulties whilst Top Caps operating the shower. LH If there is a problem with the shower control some of the push buttons will flash very fast. Roller Securing Caps Malfunction Cause Remedy RH Water Delivery Wall Jamb & Wall Channel Water supply isolated Check water supply Push buttons are Fixed Head Slider Rail Glass Panel flashing on the shower Water Delivery W

Summary of the content on the page No. 6

ENCLOSURE INSTALLATION Carefully lift the assembly onto the tray. The end Non Water Delivery Side only of the glass panel fits into slot ‘A’ on the tray. Loosely fit wall channel into glass panel jamb The wall channel end sits on the flat section of the tray ‘B’ B A Handset Adjustment B To adjust the height of the handset press the release button ‘A’ and slide the clamp bracket assembly up or down to the A desired position. The handset can be moved both vertically and horizontally until the

Summary of the content on the page No. 7

Spray Settings Check the wall channel is vertical and mark Fit the splash guard to the bottom of the panel. The handset has three different spray actions: Start, Soothe and Massage and an Eco setting. To adjust the through the 3 holes ‘A’ Note: lip faces to the outside of Enclosure and cutout is towards the wall end of the glass spray setting turn the spray plate as follows: Drill 3 x 6mm holes 1. Start - Water flows from the outer set of holes. A To select the Start setting, turn the spray p

Summary of the content on the page No. 8

Ensure glass panel is vertical Drill 4 x 3mm holes Check glass is vertical. If not OPERATION through jamb into wall remove screws, re-drill and channel re-fit as required. Low, Medium or High Flow Button - Buttons glow BLUE when pressed Re-fit rubber strip over screws Temperature Control Knob Fit 4 x screws B Warm Up/Off Button - glows BLUE when powered B STEP STEP STEP 9 10 11 Warm Up Function (Optional) 1. Press the Warm Up push-button. Carefully remove the Water Delivery System Slacken

Summary of the content on the page No. 9

The lock mode may be activated when the unit is OFF in which case the unit cannot be switched ON Carefully lift the assembly onto the tray. The end Adjust wall jamb until glass is parallel to the unless the mode is cancelled as above. of the glass panel fits into slot ‘A’ on the tray. edge of the tray ‘A’ and vertical at ‘B’. The wall channel end sits on the flat section of Removing power from the unit also cancels the mode the tray ‘B’ 4. Timeout Note! Timeout allows you to run the s

Summary of the content on the page No. 10

Check the wall channel and jamb is vertical. The edge of the glass should fit against the end COMMISSIONING Loosen screws ‘A’ to adjust from side to side. of the slot in the tray ‘B’. To adjust the glass Re-tighten screws loosen the 4 screws ‘C’ and move the panel until 1. General it is the correct postion. Re-tighten screws 1.1. Turn on the water supply to the Digital Mixer. 1.2. Check for leaks over the complete system. 1.3. Turn on the electrical supply to the Digital Mixer. For the Pump

Summary of the content on the page No. 11

Fit top cap - Water delivery side Fit top cap - Non Water delivery side Loosely fit the parking block into the wall mount ‘A’. Lift the lintel onto the glass. The panel clamps fit over the top edge of the glass and should be equally spaced on each panel C C C A Note: The lintel is supplied as a RH unit. For LH versions loosen the panel clamps o and turn them through 180 Ensure glass panels are parallel to each other STEP STEP STEP 46 47 22 Check top rail is level. Draw around parking block STEP

Summary of the content on the page No. 12

Support the weight of the column. Plug the Fixed Head Water Delivery Only Remove the lintel from glass and remove the parking block electrical cable into the connector on the cable Carefully lift the Water from the Water Delivery System 1. Match parking block 2. Spot drill hole positions 3. Drill holes with 6mm drill Delivery System column to mark on wall and place the bottom into the jamb assembly Be very careful not to scratch or damage Caution the tray 4. Plug holes 7. Secure the lintel to

Summary of the content on the page No. 13

Fit the Suppression Ferrite close to Slider Rail Water Delivery Only Fit the blanking cover on the other side Fit the fixed roller to the tray on the same side as the Water Delivery connector (See Step 42 for the Fixed Head Water Delivery) of the tray. lintel wall fixing. Note: Carefully lift the Water Note: The seal ‘A’ on the glass panel will need Note: The seal ‘A’ on the glass panel will need The Suppression Ferrite is packed with the Delivery System column to be pulled away, to allow the co

Summary of the content on the page No. 14

Loosen the screw fixing the bottom roller to Locate other side of glass door panel between Fit door retainers to both top roller brackets. Lift bottom roller up and tighten the fixing the glass with a 3mm allen key the roller and plastic glass guide Caps will ‘click’ and lock in place screw with a 3mm allen key. Fit the cap to cover the screw Caution STEP STEP STEP STEP 30 31 34 35 Connect pipework Whilst supporting the weight of the door slide Lift the glass door up and slide the rollers onto C


Alternative user manuals
# User manual Category Download
1 Kohler 116347-2 User manual Outdoor Shower 3
2 Kohler Thermostatic Electric Shower User manual Outdoor Shower 5
3 Kohler 8030A User manual Outdoor Shower 1
4 Kohler Electric Shower User manual Outdoor Shower 1
5 Amcor Rainfall Dual Showers User manual Outdoor Shower 1
6 Amcor Ultimate Shower System User manual Outdoor Shower 2
7 American Standard 1660.651 User manual Outdoor Shower 1
8 American Standard 1660.300 User manual Outdoor Shower 1
9 American Standard 3275.301 User manual Outdoor Shower 0
10 American Standard 1660.620 User manual Outdoor Shower 1
11 American Standard 1660.200 User manual Outdoor Shower 1
12 American Standard 1660.501 User manual Outdoor Shower 0
13 American Standard 3275.305 User manual Outdoor Shower 0
14 American Standard 2555.501 User manual Outdoor Shower 0
15 American Standard 1660.650 User manual Outdoor Shower 0