Summary of the content on the page No. 1
Keypad Dimmer
Owner’s Manual
2334-222
Page 1 of 24 Rev: 7/25/2013 9:16 AM
Summary of the content on the page No. 2
About Keypad Dimmer ............................................................................................................................................... 3 Features and Benefits ............................................................................................................................................... 3 Before Installation ..............................................................................................................................................
Summary of the content on the page No. 3
About Keypad Dimmer Congratulations on your purchase of the elegant, high quality Keypad Dimmer. This in-wall switch with a built-in dimmer can control up to 5 or 8 INSTEON/X10 scenes. Additionally, each button has an LED that can be easily configured as a status indicator for virtually any INSTEON device/scene you wish to monitor. Finally, it comes equipped with INSTEON’s patented dual-band communication technology for the most simple, reliable, brilliant remote control available.
Summary of the content on the page No. 4
Before Installation CAUTIONS AND WARNINGS Read and understand these instructions before installing and retain them for future reference. This product is intended for installation in accordance with the National Electrical Code and local regulations in the United States or the Canadian Electrical Code and local regulations in Canada. Use indoors only. This product is not designed or approved for use on power lines other than 100VAC- 277VAC 50/60Hz, single phase. Attempting to use this pro
Summary of the content on the page No. 5
Installation – Circuit with 1 Switch 1) Turn off circuit breaker(s) which feed the switch junction box (or remove fuse(s)). Verify that the power is off. 2) Remove trimplate from the switch, unscrew the switch you are replacing and gently pull out from wall 1 3) Disconnect wires from switch 4) Turn breaker on 5) Using a voltage tester, identify the Line and Load wires that are connected to the switch 6) Identify Neutral and Ground wires 7) Turn breaker off 8) Connect wires as fol
Summary of the content on the page No. 6
6. Turn breaker(s) off 5 7. Connect the Line wire and the black Traveler wire to the black wire on Keypad A with a wire nut 8. Cap the other Traveler wire with a wire nut 9. Cap A’s red wire 10. Connect neutral to A’s white wire 11. Connect Ground to A’s bare copper wire 12. In Keypad B’s junction box, find the Load wire (connects switch to lights, commonly red and will be the only wire connected to the switch other than the Travelers) 13. Connect the Load wire to B’s red wire 14. In
Summary of the content on the page No. 7
Installation – Circuit with 3 (or more) Switches Circuits with 3 switches are called 4-way circuits, circuits with 4 are called 5-way, and so on. All switches in multi- way circuits need to be replaced by either a Keypad and/or SwitchLinc). 1. Turn off the circuit breaker(s) which feed power to any of the switch junction boxes (pull fuse(s)) 2. Pull all switches out of their junction boxes. (2 of the switches will have 3 wires connected; the rest of the switches will have 4 wires connect
Summary of the content on the page No. 8
Local Control LEDs Button LED Meaning ON On All on OFF On All off MAIN On/Off On All on MAIN On/Off Off All off Scene button On Scene members are on Button Taps Button Type Button LED State Effect of Tap Effect of Double-tap before Tap Toggle Off Turn scene On Turn scene members on instantly Toggle On Turn scene Off Turn scene members off instantly Always On Either Turn scene On Turn scene members on instantly Always Off Either Turn scene Off Turn scene members off insta
Summary of the content on the page No. 9
INSTEON Setup A scene consists of 1 or more INSTEON devices that respond to 1 or more INSTEON controller(s). When the scene is activated (turned on), all scene members return to the states they were at when the scene was programmed. INSTEON scenes let you activate dramatic lighting moods at the touch of a button. For example, you can set all the lights in a scene to dim to 50% or turn certain lights on while turning others off, all with the tap of a button on any INSTEON controller. INSTE
Summary of the content on the page No. 10
Adding Keypad Button to a Scene as a Responder 11 1) Press and hold the scene controller button until it beeps Controller’s LED will blink 2) Tap the Keypad button you wish to be a responder of the scene at least once 3) Tap the button again if necessary to get the button’s LED to the desired state for the scene (press and hold if adding the main scene at a dimmed level) 4) Press and hold Keypad’s Set button until it double-beeps Keypad’s scene button LED will flash once and return
Summary of the content on the page No. 11
- Adjust the responder to the desired scene state (for Keypads you must tap the button at least once to reach the desired state). - Press and hold responder’s Set button until it beeps and/or LED flashes Keypad will double-beep 5) After all responders have been added, Tap Keypad’s Set button Keypad’s scene button and Set button LEDs will stop blinking Keypad’s LEDs will return to normal brightness 6) Test scene by tapping the scene button a couple of times All the responders added ab
Summary of the content on the page No. 12
B’s scene controller LED will blink and Set button LED will blink green 5) Press and hold Switch A’s Set button until it double-beeps (or LED flashes) A will double-beep and its scene controller button and Set button LED will flash B will double-beep and its LEDs will stop blinking 6) Test the group by controlling the load from A and then B The load and A’s and B’s scene controller button LEDs will all remain in sync Example: Scene with any number of “N” members We recommend us
Summary of the content on the page No. 13
4) Tap the scene button you want to change 5) Press and hold Keypad’s Set button until it beeps The scene button’s LED will begin blinking and Set button LED will blink green All illuminated LEDs on Keypad will brighten to 100% 6) Press and hold Keypad’s Set button it beeps again The button LEDs will continue blinking and Set button LED will blink red 7) Press and hold Keypad’s Set button until it beeps a third time The button LEDs will stop blinking The button function rotates to the
Summary of the content on the page No. 14
2) Press and hold Keypad’s Set button until it beeps. Set button LED will blink green 3) Send the desired X10 Address plus ON 3 times in a row (e.g. send B5-BON-B5-BON-B5-BON) Keypad will double-beep and the Set button LED will stop blinking Remove X10 Address from a Button If you are no longer going to utilize an X10 address associated with Keypad, it is very important that you remove its X10 address. Otherwise, Keypad will still listen for X10 commands (somewhat hindering INSTEON recep
Summary of the content on the page No. 15
Adjust Local Settings Each of the Keypad buttons is considered a “scene button,” meaning you can use any of the buttons on Keypad to create INSTEON scenes. Each button will control its own scene, only sending commands to devices linked specifically to that button. Dimmable responders may behave differently, depending on whether you tap, double-tap or press and hold a button to activate/deactivate a scene. Non-dimming responders will not respond to press-and- hold brighten or dim commands;
Summary of the content on the page No. 16
Local On-Level The local on-level is the default brightness level at which the light(s) physically wired to Keypad will turn on. The default local on-level is 100%, but can be set to any one of 33 settings, 32 fixed brightness levels (3% to 100%) or “Resume Bright,” which will result in the light returning to the brightness level it was at prior to being turned off. We recommend using home-management software such as HouseLinc to set the local on-level. However, you can also change it man
Summary of the content on the page No. 17
Note: For proper operation, Keypad must be programmed to operate in 6-button or 8-button mode, corresponding to whichever plate is attached. See Configuring for 6 or 8-Button Operation. Configuring for 6 or 8-Button Operation Changing to 6-Button Configuration 1) Replace the 8-button plate with the 6-button plate (see Changing to 6 or 8-Button Plate) 2) Gently pull the set button out as far is it will go 3) Wait 10 seconds 4) While simultaneously holding the On and Off buttons, ca
Summary of the content on the page No. 18
Changing Buttons Keypad buttons can be swapped out with custom-etched buttons to customize its appearance. Using a small, flat-edged screwdriver only, carefully pry up on the sides of the keys from the middle of the keypad (when possible). Make sure you are centered on the key so as to catch the small edge located there for this purpose. Please note that behind the buttons are clear plastic filler pieces; these diffuse the buttons’ LEDs’ lights more elegantly. Use care to keep these
Summary of the content on the page No. 19
Specifications General Keypad Dimmer - INSTEON 6/8-button Scene Control Keypad Product Name with Dimmer (Dual-Band) Brand INSTEON 2334-2xx Manufacturer Product Number where xx could be any number between 0 and 9. 2334-222 813922013108 Keypad Dimmer, 8 Button, White 2334-223 813922013115 Keypad Dimmer, 8 Button, Ivory 2334-224 813922013122 Keypad Dimmer, 8 Button, Almond 2334-225 813922013139 Keypad Dimmer, 8 Button, Light Almon 2334-226 813922013146 Keypad Dimmer, 8 Button, Bl
Summary of the content on the page No. 20
Software Configurable Yes, Always RF Range 150’ Open air X10 Support Yes X10 Addresses 256 max, unassigned by default INSTEON Device Category 0x01 Dimmable Lighting Control 6-button models: 0x42 INSTEON Device Subcategory 8-button models: 0x41 Mechanical Mounting Standard, single gang wall box Wires 4, 16 gauge Black - Hot White - Neutral Wires Red - Load Bare Copper - Ground Case Color Clear Set button 1 Plastic UV Stabilized Polycarbonate Beeper Yes LED 1, dual-co