Honeywell NOTIFIER IFS-2600 user manual

User manual for the device Honeywell NOTIFIER IFS-2600

Device: Honeywell NOTIFIER IFS-2600
Category: Smoke Alarm
Manufacturer: Honeywell
Size: 0.96 MB
Added : 5/24/2014
Number of pages: 80
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Honeywell NOTIFIER IFS-2600. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Honeywell NOTIFIER IFS-2600.

For your convenience

If looking through the Honeywell NOTIFIER IFS-2600 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Honeywell NOTIFIER IFS-2600 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Honeywell NOTIFIER IFS-2600 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Honeywell NOTIFIER IFS-2600 User manual - Online PDF
Advertisement
« Page 1 of 80 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Honeywell NOTIFIER IFS-2600 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Honeywell NOTIFIER IFS-2600. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

IFS-2600
Fire Indicator Panel
TECHNICAL, PROGRAMMING
& INSTALLATION MANUAL
8/05/08 Rev: 3.01
P/N 10069 ECN08-0066

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Installation Precautions Remove all electronic assemblies prior to any Adherence to the following will aid in drilling, filing, reaming, or punching of the enclosure. When possible, make all cable entries problem-free installation with long-term from the sides or rear. Before making reliability: modifications, verify that they will not interfere with battery, transformer, or printed circuit board location. WARNING - Several different sources of power can be connected to the fire alarm control Do

Summary of the content on the page No. 4

Documentation Feedback Your feedback helps us keep our documentation up to date and accurate. If you have any comments or suggestions about our printed manuals you can email us. Please include the following information:  Product name and version number (if applicable)  Manual part number and revision (found on the front cover)  Page number  Brief description of the content you think should be improved or corrected  Your suggestion for how to correct/improve documentation Send email messages

Summary of the content on the page No. 5

IFS-2600 Installation & Programming Manual Page 1 TABLE OF CONTENTS COMPATIBLE DETECTORS................................................................................................5 OVERVIEW...........................................................................................................................6 CAUTION ........................................................................................................................................................................... 6

Summary of the content on the page No. 6

Page 2 IFS-2600 Installation & Programming Manual PCB2005 TERMINATION BOARD............................................................................................................................... 14 INTERNAL 5VDC POWER SUPPLY TP8................................................................................................................... 14 POWER SUPPLY COMPARATOR REFERENCE VOLTAGE TP10 .........................................................................14 NON ADJUSTABLE TEST PO

Summary of the content on the page No. 7

IFS-2600 Installation & Programming Manual Page 3 MAIN MENU.................................................................................................................................................................... 30 EXIT PROGRAMMING MODE ................................................................................................................................... 31 ZONE PROGRAMMING....................................................................................................

Summary of the content on the page No. 8

Page 4 IFS-2600 Installation & Programming Manual APPENDIX F ...................................................................................................................... 43 GLOSSARY OF TERMS................................................................................................................................................. 43 APPENDIX G...................................................................................................................... 44 SUMMARY OF TERMINAT

Summary of the content on the page No. 9

IFS-2600 Installation & Programming Manual Page 5 COMPATIBLE DETECTORS Make Model Type Model Number System Sensor Thermal Type A 5451 AUS System Sensor Thermal Type A 51A51 System Sensor Thermal Type B 4451 AUS System Sensor Thermal Type B 51B51 System Sensor Thermal Type B Sealed 51B51S System Sensor Thermal Type C 51C51 System Sensor Thermal Type D 51D51 System Sensor Smoke Photo-Optical 2151 AUS System Sensor Smoke Photo-Optical 2151B AUS System Sensor Smoke Ionisation 1151 AUS System Sensor

Summary of the content on the page No. 10

Page 6 IFS-2600 Installation & Programming Manual OVERVIEW IFS-2600 Fire Indicator Panel (FIP) is designed to provide simplicity to the end user. The FIP uses both a liquid crystal display and conventional LED displays for fast and accurate display of system status and changing events. A custom designed membrane keypad is used together with the liquid crystal display and LED indicators to provide fast, efficient and simple modes of operation. The keypad also provides the required flexibility for

Summary of the content on the page No. 11

IFS-2600 Installation & Programming Manual Page 7 SPECIFICATION Cabinet Zinc Sealed Steel 1.6mm Powder Coated Hinged Inner Door Hinged Outer Door Outside Dimensions 2608 (8 zones) 394mm H x 390mm W x 180mm D* 2624 (24 zones) 750mm H x 390mm W x 180mm D* 2600 (32 to 64 zones) 18U, 28U & 40U Cabinets Battery Box *Note: the depth quoted is including the door and break glass. The internal cabinet depth not including he door and break glass is 140mm. AC Operational Voltage 240 VAC 50Hz + 10% Internal

Summary of the content on the page No. 12

Page 8 IFS-2600 Installation & Programming Manual SYSTEM EXPANSION Zones Qty Hardware Required Product Code 8 1 Main Control Board PCB-2004 1 Main Termination board PCB-2005 1 Power Supply board PCB-2006 16 1 Main Control board PCB-2004 1 Main Termination board PCB-2005 1 Power Supply board PCB-2006 1 8 Zone Expansion board PCB-804G3 1 16 Zone Indicator board PCB-816 24 1 Main Control board PCB-2004 1 Main Termination board PCB-2005 1 Power Supply board PCB-2006 2 8 Zone Expansion board PCB-804G

Summary of the content on the page No. 13

IFS-2600 Installation & Programming Manual Page 9 POWER SUPPLY RATINGS AND SETTINGS INTERNAL 24 VDC (nom) 3.0A MAIN POWER SUPPLY This supply's primary function is to power panel logic and all external operations of the FIP, i.e.: detection circuits, ancillary circuits, etc. This supply meets the requirements of AS4428.5. AC Input 30 VAC +10% - 15% Output Current 3.0 AMPS Output Voltage 26.5 VDC Current Limit 3.0 AMPS Output Ripple 50 mV INTERNAL 27.3V DC 1.5A BATTERY CHARGER Its primary function

Summary of the content on the page No. 14

Page 10 IFS-2600 Installation & Programming Manual EXTERNAL 27VDC POWER SUPPLY This supply is used in addition to the internal power supply for large systems. Its primary function is to power any additional ancillary loads of the FIP up to 7 amps. This supply meets the requirements of AS4428.5 Important Notes: When using external power supply, JP1 link on IFS2006E must be fitted to enable external PSU monitoring. If this supply is used to power a NI-2008 gas module, the following additional comp

Summary of the content on the page No. 15

IFS-2600 Installation & Programming Manual Page 11 TECHNICAL DESCRIPTION GENERAL The IFS-2600 in its most basic form comprises of three boards, the main control board, the main termination board and the power supply board. 2 The main control board contains the Microprocessor, EPROM, RAM and E ROM. The main control board also has the liquid crystal display and keypad attached. All of the "delicate" electronics have been placed on this board. The main control board complete with the inner door is

Summary of the content on the page No. 16

Page 12 IFS-2600 Installation & Programming Manual AZF DESCRIPTION The AZF's on the IFS-2600 are monitored and scanned by custom thick film hybrids. These hybrid IC's significantly reduce the possibility of false alarms and improve product efficiency and reliability. The total Alarm Zone loop resistance is the sum of the end of line resistor (EOLR 4K7) plus all the parallel connected detector loads. AZF SUPERVISORY CURRENT The supervisory current flows through the external terminal AZF+, through

Summary of the content on the page No. 17

IFS-2600 Installation & Programming Manual Page 13 PRINTER OUTPUT The printer port is designed to be used during testing and commissioning of the panel. The serial printer will report alarms and faults together with the date and time of the event. The printer can also be used during “walk test” mode to produce a history of the test and can also be used to print current programming configuration. A DB9 plug male is provided at the top of the main termination board. This communication port will co

Summary of the content on the page No. 18

Page 14 IFS-2600 Installation & Programming Manual ALIGNMENT AND ADJUSTMENT PCB2006 POWER SUPPLY BOARD INTERNAL 24VDC (nom) POWER SUPPLY With batteries disconnected and no alarms present, measure voltage across the 0V and MAIN test points on the 2006 power supply board and, if necessary, adjust the multi-turn potentiometer VR2 until voltage is 26.5V 0.05V (26.45V – 26.55V). Current limiting is fixed and field adjustment is not possible. INTERNAL 27.3 VDC BATTERY CHARGER With batteries disconnec

Summary of the content on the page No. 19

IFS-2600 Installation & Programming Manual Page 15 ALARM THRESHOLD COMPARATOR TP7 With the panel in the quiescent mode, measure and take note of the INTERNAL 24V DC POWER SUPPLY as above. Measure voltage between system 0V and TP7. Adjust multi-turn potentiometer VR4, and adjust until the voltage is as per the following table. Rail Voltage 3.3V Setting Range 20.6 2.833 2.80 to 2.86 21.0 2.888 2.86 to 2.92 21.5 2.956 2.93 to 2.99 22.0 3.025 2.99 to 3.06 22.5 3.094 3.06 to 3.12 23.0 3.163 3.13 to 3

Summary of the content on the page No. 20

Page 16 IFS-2600 Installation & Programming Manual CONFIGURATION JUMPERS IFS2004 - JP3 DEFAULT Holding a short across these pins for 5 seconds during start-up causes the panel to reset to standard factory defaults. The panel will give 4 beeps after reset, to acknowledge default on start-up. IFS2004 - JP4 PROGRAM DISABLE When fitted, jumper between these pins to inhibit program changes. IFS2004 - JP5 CPU RESET With panel operating, a momentary short across these pins will cause a CPU restart. IFS


Alternative user manuals
# User manual Category Download
1 Honeywell DUCT-MOUNT AND OUTDOOR-MOUNT H7625B User manual Smoke Alarm 11
2 Honeywell DUCT-MOUNT AND OUTDOOR-MOUNT H7635B User manual Smoke Alarm 3
3 Honeywell DUCT-MOUNT AND OUTDOOR-MOUNT H7655B User manual Smoke Alarm 3
4 Honeywell DUCT-MOUNT AND OUTDOOR-MOUNT H7635C User manual Smoke Alarm 6
5 Honeywell 25/50ZS User manual Smoke Alarm 12
6 Honeywell 25/50ZST User manual Smoke Alarm 1
7 Honeywell EXCEL ADT-HRSI User manual Smoke Alarm 7
8 Honeywell ANN-RLY User manual Smoke Alarm 2
9 Honeywell 50ZST User manual Smoke Alarm 0
10 Honeywell C User manual Smoke Alarm 1
11 Honeywell C7015A User manual Smoke Alarm 14
12 Honeywell C7021F User manual Smoke Alarm 0
13 Honeywell C7021B User manual Smoke Alarm 1
14 Honeywell C7021D User manual Smoke Alarm 1
15 Honeywell C7021K User manual Smoke Alarm 0
16 Adobe CS3 User manual Smoke Alarm 1
17 ADT Security Services ADT-LCD40 User manual Smoke Alarm 6
18 ADT Security Services Safewatch Pro 2000 User manual Smoke Alarm 5
19 ADT Security Services SAVS20ADT-1 User manual Smoke Alarm 3
20 ADT Security Services Unimode 9600 User manual Smoke Alarm 7