Honeywell IPGSM-DP user manual

User manual for the device Honeywell IPGSM-DP

Device: Honeywell IPGSM-DP
Category: Smoke Alarm
Manufacturer: Honeywell
Size: 0.5 MB
Added : 9/25/2013
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Honeywell IPGSM-DP. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Honeywell IPGSM-DP.

For your convenience

If looking through the Honeywell IPGSM-DP user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Honeywell IPGSM-DP on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Honeywell IPGSM-DP to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Honeywell IPGSM-DP User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Honeywell IPGSM-DP but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Honeywell IPGSM-DP. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

LOW BATT
AC LOSS
AC ON
IPGSM-DP Commercial Fire Communicator
RADIO TROUBLE


IPGSM-DP
IPGSM-DP
Commercial Fire Communicator
Commercial Fire Communicator


I In ns st ta alllla at tiio on n a an nd d S Se et tu up p G Gu uiid de e









800-08074 1/11 Rev. A

Summary of the content on the page No. 2

Contents General Information .......................................................................................................................1 Package Contents .......................................................................................................................1 Compatible Fire Panels ..............................................................................................................1 Operation..............................................................

Summary of the content on the page No. 3

IPGSM-DP Commercial Fire Communicator – Installation and Setup Guide General Information The IPGSM-DP Commercial Fire Communicator (henceforth referred to as IPGSM-DP) includes everything you need to upgrade a commercial fire system that previously reported by POTS to a system that uses the Internet as its primary reporting path, and uses a GSM cellular reporting path as a backup. In addition, this communicator utilizes a sophisticated power module (PowerBoost1) that monitors and reports

Summary of the content on the page No. 4

IPGSM-DP Commercial Fire Communicator – Installation and Setup Guide STEP 1 – Activate the SIM and Setup the Customer Account The communicator requires a subscriber account (customer account) to be setup with AlarmNet Direct. This is accomplished by registering the communicator's iGSM communications module with AlarmNet. Registering, enables the fire panel to send reports. To setup the customer account you will need to contact the central monitoring station to get account information,

Summary of the content on the page No. 5

IPGSM-DP Commercial Fire Communicator – Installation and Setup Guide STEP 3 – Determine the Signal Strength and Select a Location IMPORTANT - Do Not mount this device outdoors. RF Exposure Warning - The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in con- junction with any other antenna or transmitter. When choosing a suitable mounting location, understand that signal st

Summary of the content on the page No. 6

IPGSM-DP Commercial Fire Communicator – Installation and Setup Guide 3. Install the two plastic mounting rails for the LED Display board. They simply snap into the back plate holes. 4. Connect the LED Display board to its connector, then slide the board into the mounting rails. (Yellow LED and Buzzer are on top.) 5. Carefully remove the packaging material that surrounds the PowerBoost1. 6. Mount the PowerBoost1 on the three unused standoffs. Use the plastic screw (prevents shorting)

Summary of the content on the page No. 7

IBS GPRS M1 M0 RSSI Data Out IPGSM-DP Commercial Fire Communicator – Installation and Setup Guide ANTENNA WALL OUTLET BOX (K14358) TRANSFORMER (N8167) NUT, WASHER ANTENNA MOUNTING ADAPTER CABINET DOOR ON 15 2 3 4 RED GREEN Dialer Capture Module FOR EXTERNAL ANTENNA 50 OHM MMCX ONLY 7720P PROGRAMMER PORT NOT FOR TELEPHONE SERVICE USE! PRIMARY POWER: 9 - 16.5 VAC BATTERY CURRENT: 900mA PEAK, 70mA STANDBY TO Facility BATTERY: 8V. 3.1 AHr FOR 24 Hr BACKUP FCC:XXXXXXXXXX IC: YYYYYYYYYY Gr

Summary of the content on the page No. 8

IPGSM-DP Commercial Fire Communicator – Installation and Setup Guide STEP 5 – Program the Communications Module You must use the 7720P Programming tool to program the IPGSM-DP. When using the 7720P Programming tool, the values given below are for most installations. Press the [#] key to accept the displayed default value (xxx) or enter the new value and press the [#] key for the next prompt. Use the [Space] key to scroll through a list of options. (no display) 1. Connect the 77

Summary of the content on the page No. 9

IPGSM-DP Commercial Fire Communicator – Installation and Setup Guide To exit the programming mode, press [N] in response to the "Review?" prompt. Then press [Y] to the "Exit Prog Mode?" prompt. Upon exiting, the root file is updated to log the changes made. A message is displayed telling the user that this step is being executed. When complete, the message "DONE" is displayed to indicate the file was successfully uploaded. Note: If critical configuration changes were made, such as the

Summary of the content on the page No. 10

IPGSM-DP Commercial Fire Communicator – Installation and Setup Guide IPGSM-DP Trouble Detection Information Telco 1 is used for the Fire Panel to output contact ID messages to the IPGSM-DP, and Telco 2 is used by the IPGSM-DP to report faults to the Fire Panel. If Telco 1 is not operational, the Fire Panel will use Telco 2 to report events if there are no faults in the iGSM Communications module. Fault Condition Indication to Fire Panel PowerBoost1 fault Telco 2 is cut. iGSM Communic

Summary of the content on the page No. 11

IPGSM-DP Commercial Fire Communicator – Installation and Setup Guide Violet Note: If a wire pulled out of the LED Board Connector LED Board Black refer to the diagram on right and reinsert wire, ensuring Connector White the connector pin is locked in. Wires NC Red NC Brown Yellow Gray PowerBoost1 Module Information LED Indicator STATUS AC AC power available. (green) ACTIVE Cyclical flashing – normal communications. (green) Repetition of 3 flashes – loss of communication

Summary of the content on the page No. 12

IBS GPRS M1 M0 RSSI IPGSM-DP Commercial Fire Communicator – Installation and Setup Guide iGSM Communications Module Information ON – NOT registered with AlarmNet. GRN OFF – Registered with AlarmNet. FAST BLINK – Download session with Compass in progress. PRIMARY POWER: 9 - 16.5 VAC SLOW BLINK – In unison with yellow LED, CURRENT: 900mA PEAK, 70mA STANDBY 7720P BATTERY: 8V. 3.1 AHr FOR 24 Hr BACKUP Programmer registration in progress. Port

Summary of the content on the page No. 13

IPGSM-DP Commercial Fire Communicator – Installation and Setup Guide RF Specifications Transmission Transmit Receive Receive Number Channel Duplex Frequency Power Frequency of Separation Band Sensitivity Spacing Channels (MHz) (dBm) (MHz) (kHz) (dBm) (MHz) GSM 850 824-849 33 869-894 -107 124 200 45 GSM 900 890-915 33 935-960 -107 124 200 45 GSM 1800 1710-1785 30 1805-1880 -106 374 200 95 GSM 1900 1850-1910 30 1930-1990 -105.5 299 200 80 IPGSM-DP Specifications ITEM SPEC

Summary of the content on the page No. 14

IPGSM-DP Commercial Fire Communicator – Installation and Setup Guide NOTES – 12 –

Summary of the content on the page No. 15

IBS GPRS M1 M0 RSSI Wiring Diagram The wiring diagram below is depicted for point-to-point electrical connection checks used for troubleshooting or component replacement. It is not intended to show the physical routing of wires. When replacing a wire or component, ensure the wire is routed in the same manner as the original factory wire. WALL OUTLET TRANSFORMER BOX (K14358) ANTENNA (N8167) (Buzzer) OPTIONAL CABINET WHT (LO BATT) TAMPER SWITCH CABINET DOOR LED Display RADIO PowerBoost1 Bu

Summary of the content on the page No. 16

FCC STATEMENT Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio


Alternative user manuals
# User manual Category Download
1 Honeywell DUCT-MOUNT AND OUTDOOR-MOUNT H7625B User manual Smoke Alarm 11
2 Honeywell DUCT-MOUNT AND OUTDOOR-MOUNT H7635B User manual Smoke Alarm 3
3 Honeywell DUCT-MOUNT AND OUTDOOR-MOUNT H7655B User manual Smoke Alarm 3
4 Honeywell DUCT-MOUNT AND OUTDOOR-MOUNT H7635C User manual Smoke Alarm 6
5 Honeywell 25/50ZS User manual Smoke Alarm 12
6 Honeywell 25/50ZST User manual Smoke Alarm 1
7 Honeywell EXCEL ADT-HRSI User manual Smoke Alarm 7
8 Honeywell ANN-RLY User manual Smoke Alarm 2
9 Honeywell 50ZST User manual Smoke Alarm 0
10 Honeywell C User manual Smoke Alarm 1
11 Honeywell C7015A User manual Smoke Alarm 14
12 Honeywell C7021F User manual Smoke Alarm 0
13 Honeywell C7021B User manual Smoke Alarm 1
14 Honeywell C7021D User manual Smoke Alarm 1
15 Honeywell C7021K User manual Smoke Alarm 0
16 Adobe CS3 User manual Smoke Alarm 1
17 ADT Security Services ADT-LCD40 User manual Smoke Alarm 6
18 ADT Security Services Safewatch Pro 2000 User manual Smoke Alarm 5
19 ADT Security Services SAVS20ADT-1 User manual Smoke Alarm 3
20 ADT Security Services Unimode 9600 User manual Smoke Alarm 7