Summary of the content on the page No. 1
TM
PRO PLUS PORTABLE WHEELCHAIR SCALE
MODEL 2450KL
TM
BALANCE PORTATIVE PRO PLUS
POUR FAUTEUIL ROULANT
MODELE 2450KL
TM
BALANZA PORTABLE PRO PLUS PARA
SILLA DE RUEDAS
MODELO 2450KL
OPERATION MANUAL
MODE D'EMPLOI
MANUAL DE OPERACIÓN
Summary of the content on the page No. 2
TM PRO PLUS PORTABLE WHEELCHAIR SCALE MODEL 2450KL Thank you for your purchase of this product. Please read this manual carefully and keep it handy for ready reference. Merci d'avoir acheté ce produit. Veuillez lire attentivement ce manuel et le garder à portée de main pour pouvoir le consulter à tout moment Gracias por la adquisición de este producto. Lea por favor este manual cuidadosamente y manténgalo a su alcance para una pronta referencia. ENGLISH..................
Summary of the content on the page No. 3
CAUTION AND WARNING To prevent injury and damage to your scale, please follow these instructions very carefully. • For accurate weighing the scale must be placed on a flat and a stable surface, locking screw is locked properly and the scale bottom is not touching the floor. • For accurate weighing, verify proper operation according to the procedure described in this manual before each use. • Do not use in the presence of flammable materials. • Operating at other voltages and frequen
Summary of the content on the page No. 4
SET UP Parts List: (1) Scale Assembly (1) AC Adapter (1) Display Assembly (1) Load Cell Cable (4) Plastic Feet Assemblies Tools required: Phillips head screwdriver. Remove each assembly from the carton and unwrap packing material carefully to prevent scratching the unit’s parts. Figure 1. Assembly After Shipment Scale - Opening and Assembly Instructions 1. Begin with the scale in the folded upright position resting on its ramps, as in Figure 2a. 2. Lightly slide up the display
Summary of the content on the page No. 5
SET UP Figure 2a Figure 2b 9. Tighten the width adjusting knob in order to lock the width adjusting mechanism. 10. Remove the stand at the rear of the display assembly by unscrewing 4 screws, in order to connect load cell cable and power cord to the display assembly (see Figure 3). 11. Connect the load cell cable connector to the load cell port on the rear of the display assembly and insert and secure the cable into the center channel in the display. 12. Connect power cord
Summary of the content on the page No. 6
SET UP Preparing the Scale for Use 1. Remove protective plastic film from keypad and display. 2. Place batteries in the battery holder (see “Replacing Batteries”). 3. Plug the scale’s AC adapter into the power source. 4. Press the ON/OFF button to turn the scale on. The display will show “Health o Meter (a) Pro-Plus” and then ”000Lb00oz”. 5. Place a weight [not to exceed 600 Lb (270 Kg)] on the scale. The display should read “WEIGHING“ until the weight calculation is complete an
Summary of the content on the page No. 7
OPERATION INSTRUCTIONS 1. Press the ON/OFF button to turn the scale on. 2. Wait until ”000Lb00oz” and “ZERO” on the left side of the display will appear. 3. Bring the wheelchair close to the scale ramps. Unscrew the width adjusting knob and adjust the scale width by moving the left ramp. NOTE: Often front and rear wheels on wheelchairs are not perfectly aligned. Make sure that both front and rear wheels mount the ramps. 4. Tighten the width adjusting knob in order to lock the wi
Summary of the content on the page No. 8
OPERATION INSTRUCTIONS Figure 5. Keypad ITEM DESCRIPTION FUNCTION POWER Turns scale ON and OFF. ZERO Zeros the scale prior to weighing. Holds the value of the weighed object on the display until HOLD/RELEASE the button is pressed again to clear the value. Also used to scroll down in the menu. Allows repeated weighing of the patient without stepping REWEIGH off the scale. Toggles between kilograms or pounds. Also used to scroll KG/LB button up in the menu. MENU Enter
Summary of the content on the page No. 9
OPERATION INSTRUCTIONS MENU In the menu screen the user can set preferences and/or instruct the scale how to handle stored data. The menu can be navigated using the up and down keys ( ) or by entering the associated menu position number with the keypad. The menu has a “roll-over” way of working: when the user scrolls to the bottom of the menu and presses the down button, it will return to the top of the menu. Figure 6. Main Menu 01 WEIGHT DISPLAY MODE (only applies to pound
Summary of the content on the page No. 10
OPERATION INSTRUCTIONS 02 TARE WEIGHT NOTE: Due to the scale’s sensitivity, we recommend using the REWEIGH function prior to setting the TARE weight, in order to eliminate any operator interference with the item to be tared out. There are two ways to manually enter a tare weight (such as the weight of a wheelchair, shoes, etc): press MENU (1) and select option 02-Tare Weight or press TARE (9). If there is no weight on the scale platform (value displayed is zero and there is no tare) a
Summary of the content on the page No. 11
OPERATION INSTRUCTIONS 3. The scale will prompt you to enter the patient’s height. Use the keypad to enter the height in 1/4" (1=1/4, 2=1/2, 3=3/4) or 1 cm increments (use inches for weight in lb, cm for kg). Press ENTER. 4. Display will read the patient’s BMI. The scale offers you two options to manage your information: to transfer/download the values or to store them. The first option automatically downloads (transfers) the value to your PC. The second option stores the
Summary of the content on the page No. 12
OPERATION INSTRUCTIONS 04 Transfer now All the values stored in memory are transferred to the PC and the scale memory is cleared of all values. If the transfer was unsuccessful, the values are kept in memory until successfully transferred or cleared. 05 Clear memory All the values stored in memory will be cleared. 04 SCALE SETTINGS 01 Auto Hold Time The user can determine how long to display the weight reading once it is determined, regardless of whether the patient
Summary of the content on the page No. 13
OPERATION INSTRUCTIONS 03 Auto Off Time The user can determine how long the scale will operate before turning off automatically due to inactivity. Default time is 10 minutes. If the value is set to zero, the auto off function is disabled. 04 Tone Volume There is an option to adjust the beeping tone of the scale. This tone should sound when the scale has determined the weight on the platform, when a key is pressed, after the scale is turned on, at the end of self-test, or in t
Summary of the content on the page No. 14
OPERATION INSTRUCTIONS 06 Display Backlight The user can set the brightness of the backlight. 07 Display Contrast The user can set the brightness of the LCD. 08 Live Weight By selecting “Yes” the user can set the Live Weight mode to deactivate the motion-sensing mode. In the Live Weight mode the weight displayed will fluctuate with the patient’s movement; the scale will not lock on quickly to the weight as is the case in the motion-sensing mode. Press the REWEIGH button
Summary of the content on the page No. 15
OPERATION INSTRUCTIONS Set the date using the up and down keys and enter the values on the keypad. 02 About This screen displays the software version of the scale. 06 SYSTEM TEST 01 Battery Test The scale will display the estimated amount of battery life remaining until the batteries will have to be replaced. NOTE: In order to complete the battery test, the scale must be powered by batteries only. Unplug the scale from AC power source prior to battery test. 02
Summary of the content on the page No. 16
OPERATION INSTRUCTIONS 03 UI Test The scale has a diagnostic routine where it tests the User Interface (UI) hardware functionality (LCD, keypad). In order to do this the user has to press all the keys according to the messages displayed on the screen. If the requested command was not received or wrong button was pressed, the following message will be displayed. If after 10 seconds the requested command was not received, the following message will be displayed. If “UI Error
Summary of the content on the page No. 17
OPERATION INSTRUCTIONS 02 Disp Height & ID When the user selects to display the height and ID of the user, it will be displayed at the bottom of the screen. We recommend the use of this function to ensure that the patient’s correct ID and height have been entered. 03 Prompt For Height When this option is activated, the user will be asked to enter the patient’s height after every weighing. 04 Prompt For ID When this option is activated, the user will be asked to en
Summary of the content on the page No. 18
MAINTENANCE GENERAL This section provides instructions for maintenance, cleaning, troubleshooting and operator TM replaceable parts for the Pro Plus Portable Wheelchair Scale Model 2450KL. Maintenance operations other than those described in this section should be performed by qualified service personnel. MAINTENANCE Before first use and after periods of non-use, check the scale for proper operation and function. If the scale does not operate correctly, refer to qualified service
Summary of the content on the page No. 19
TROUBLESHOOTING Refer to the following instructions to check and correct any failure before contacting service personnel. SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Scale does not turn on 1. Dead Battery 1. Replace batteries 2. Faulty electrical outlet 2. Use a different outlet 3. Bad power supply 3. Replace adapter Questionable weight or 1. External object 1. Remove interfering object the scale does not zero interfering with the scale from the scale 2. The display did not show 2. A
Summary of the content on the page No. 20
CALIBRATION PATH The calibration is performed in Kg or Lb, according to the units of measure used upon entering into the calibration path. Operator Action Display 1. Press ON/OFF button and immediately press and Calibration hold HOLD/RELEASE button for 3-4 seconds Process 2. Press ENTER Enter load weight 600.0 3. Using keys and/or the keypad, set the Zero calibration calibration load to at least 200 lbs (for best results Please clear the scale and greater accuracy, use a 600 lb we