Greenheck Fan DH100ACDCLP user manual

User manual for the device Greenheck Fan DH100ACDCLP

Device: Greenheck Fan DH100ACDCLP
Category: Smoke Alarm
Manufacturer: Greenheck Fan
Size: 0.79 MB
Added : 11/25/2014
Number of pages: 8
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Greenheck Fan DH100ACDCLP. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Greenheck Fan DH100ACDCLP.

For your convenience

If looking through the Greenheck Fan DH100ACDCLP user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Greenheck Fan DH100ACDCLP on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Greenheck Fan DH100ACDCLP to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Greenheck Fan DH100ACDCLP User manual - Online PDF
Advertisement
« Page 1 of 8 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Greenheck Fan DH100ACDCLP but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Greenheck Fan DH100ACDCLP. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

DUCT SMOKE DETECTOR
DH100ACDCLP
Purpose/Application
National and local safety standards and codes recognize
the ability of air duct systems to transfer smoke, toxic
gases, and flame from area to area. Sometimes smoke can
be of such quantity as to be a serious hazard to life safety
unless blowers are shut down and dampers are actuated.
The primary purpose of duct smoke detection is to prevent
injury, panic, and property damage by reducing the spread
(recirculation) of smoke. The detector s

Summary of the content on the page No. 2

SLEEvE LENgTH ORDERiNg OPTiONS Sleeve Length Height less than 25 in. (635mm): 24 in. (610mm) sleeve (15 in. [381mm]‘A’ dimension) (detector mounted parallel to sleeve) Height greater than or equal to 25 in. (635mm): 21 in. (533mm) sleeve (11 in. [279mm] ‘A’ dimension) (detector mounted perpendicular to sleeve) Figure 1: Label applied to dampers with factory mounted duct smoke detectors.

Summary of the content on the page No. 3

SPACE ENvELOPES ELECTRiCAL RATiNgS Dampers Less Than 25 inches (635mm) in Height T ypical Actuator (ML series shown; other 3 in. actuators available) 3 6 ⁄ 4 in. Single Point W iring (Standar d) Smoke detector , actuator , and al l cont ro l options ar e pr ewir ed to junction box at the factor y. Dampers Equal To Or greater Than 25 inches (635mm) in Height 2 3/4 in. (70mm) Typical Actuator (other actuators available) 15 in. (381mm) Single Point Wiring (Standard): Smoke detector,

Summary of the content on the page No. 4

WiRiNg DiAgRAMS DUCT SMOKE DETECTOR Fusible Link RED DH100ACDCLP DUCT DETECTOR 1 23 45 67 8 910C A B 24 VAC/VDC 11 12 13 14 15 16 17 18 19 20 BLUE RED DH100ACDCLP DUCT DETECTOR 1 2 34 5 67 8 910C A B L1 115 VAC 11 12 13 14 15 16 17 18 19 20 L2 BLUE RED DH100ACDCLP DUCT DETECTOR MOTOR OPTIONAL SECOND MOTOR 220/240 VAC 23 4 5 6 7 89 10 B C 1 A 11 12 13 14 15 16 17 18 19 20 MOTOR OPTIONAL THIRD MOTOR BLUE MOTOR 1. CONDUIT RUNS WHICH EXCEED 72" MUST HAVE GREEN GROUND WIRE. 2. FLEX CONDUIT MUST BE S

Summary of the content on the page No. 5

WiRiNg DiAgRAMS DUCT SMOKE DETECTOR RRL RED DH100ACDCLP DUCT DETECTOR RRL 1 23 45 67 8 910C A B 24 VAC/VDC 11 12 13 14 15 16 17 18 19 20 BLUE RED DH100ACDCLP DUCT DETECTOR 1 2 34 5 67 8 910C A B 115 VAC L1 11 12 13 14 15 16 17 18 19 20 L2 BLUE RED DH100ACDCLP DUCT DETECTOR MOTOR OPTIONAL SECOND MOTOR 220/240 VAC 1 235 4 6 7 8 9 10 A BC 11 12 13 14 15 16 17 18 19 20 MOTOR OPTIONAL THIRD MOTOR BLUE MOTOR 1. CONDUIT RUNS WHICH EXCEED 72" MUST HAVE GREEN GROUND WIRE. 2. FLEX CONDUIT MUST BE SECURED

Summary of the content on the page No. 6

WiRiNg DiAgRAMS DUCT SMOKE DETECTOR TOR RED THE OCI WIRES MUST BE CHECKED TO VERIFY WHICH SET INDICATES THE CLOSED POSITION OF DH100ACDCLP DUCT DETECTOR DAMPER. THIS SET OF WIRES SHOULD THEN BE LABELED WITH A BLUE WIRE MARKER (382169). TOR 1 23 45 67 8 910C A B 24 VAC/VDC 11 12 13 14 15 16 17 18 19 20 BLUE SWITCH #2 RED SWITCH #1 SWITCHING DEVICE (BY OTHERS) DH100ACDCLP DUCT DETECTOR (OVERRIDE) 1 2 34 5 67 8 910C A B L1 115 VAC (PRIMARY) 11 12 13 14 15 16 17 18 19 20 L2 RED BLUE DH100ACDCLP D

Summary of the content on the page No. 7

WiRiNg DiAgRAMS DUCT SMOKE DETECTOR RRL W/ EP Switch RED DH100ACDCLP DUCT DETECTOR RRL 1 23 45 67 8 910C A B 24 VAC/VDC 11 12 13 14 15 16 17 18 19 20 BLUE RED DH100ACDCLP DUCT DETECTOR 1 2 34 5 67 8 910C A B 115 VAC L1 11 12 13 14 15 16 17 18 19 20 L2 E/P SWITCH RED BLUE DH100ACDCLP DUCT DETECTOR RED RED OPTIONAL 220/240 VAC SECOND E/P SWITCH 1 23 45 67 8 910 A BC 11 12 13 14 15 16 17 18 19 20 E/P SWITCH RED RED OPTIONAL BLUE THIRD E/P SWITCH E/P SWITCH RED RED 1. CONDUIT RUNS WHICH EXCEED 72"

Summary of the content on the page No. 8

WiRiNg DiAgRAMS DUCT SMOKE DETECTOR TOR w/ EP Switch RED THE OCI WIRES MUST BE CHECKED TO VERIFY WHICH SET INDICATES THE CLOSED POSITION OF DH100ACDCLP DUCT DETECTOR DAMPER. THIS SET OF WIRES SHOULD THEN BE LABELED WITH A BLUE WIRE MARKER (382169). TOR 1 23 45 67 8 910C A B 24 VAC/VDC 11 12 13 14 15 16 17 18 19 20 BLUE SWITCH #2 RED SWITCH #1 SWITCHING DEVICE (BY OTHERS) DH100ACDCLP DUCT DETECTOR (OVERRIDE) 1 2 34 5 67 8 910C A B L1 115 VAC (PRIMARY) 11 12 13 14 15 16 17 18 19 20 L2 E/P SWITCH


Alternative user manuals
# User manual Category Download
1 Greenheck Fan Combination Fire Smoke Damper SEFSDR-511 User manual Smoke Alarm 0
2 Greenheck Fan FSDR-XXX User manual Smoke Alarm 0
3 Greenheck Fan Combination Fire Smoke Dampers FSD-M211 User manual Smoke Alarm 0
4 Greenheck Fan Smoke Dampers SMD-401M User manual Smoke Alarm 0
5 Greenheck Fan No Flow Duct Smoke Detector User manual Smoke Alarm 0
6 Greenheck Fan Combination Fire Smoke Dampers SSFSDR-511 User manual Smoke Alarm 0
7 Greenheck Fan Smoke Dampers SMD-203 User manual Smoke Alarm 0
8 Greenheck Fan SEFSDR-XXX User manual Smoke Alarm 0
9 Greenheck Fan Smoke Dampers SSSMDR-501 User manual Smoke Alarm 0
10 Greenheck Fan Duct Smoke Detector none User manual Smoke Alarm 0
11 Greenheck Fan SSFSDR-XXX User manual Smoke Alarm 0
12 Greenheck Fan Combination Fire Smoke Damper FSD-211 User manual Smoke Alarm 1
13 Adobe CS3 User manual Smoke Alarm 1
14 ADT Security Services ADT-LCD40 User manual Smoke Alarm 6
15 ADT Security Services Safewatch Pro 2000 User manual Smoke Alarm 5
16 ADT Security Services SAVS20ADT-1 User manual Smoke Alarm 3
17 ADT Security Services Unimode 9600 User manual Smoke Alarm 7