Summary of the content on the page No. 1
Owner's Manual
fle_16 Ce_n|ro| RrepiL byeram_hm|
Remote Control Liquid Propane Gas Patio Fireplace
For Outdoor Installation & Operation
Model 89795
US
,/_ WARNING:
Read this Owner's Manual carefully and be sure
Note to installer: Leave this Owner's Manual
your patio fireplace is properly assembled, installed
with the consumer after delivery and/or installation.
and maintained. Failure to follow these instructions
Note to Consumer: Leave this Owner's
could result in serious bodily injury and/or p
Summary of the content on the page No. 2
I, I.3F.X;JI[m WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury, Warranty ................................ 2 death or property damage and will void your product Safety Instructions ................................ 2 warranty. Read the installation, operation and Contents for Hardware Pack & Packing List ........... 5 maintenance instructions thoroughly before Parts Diagram ................................. 6 installing or servicing this equipment. P
Summary of the content on the page No. 3
Fig 1 Minimum clearance from combustibles. //_ WARNING (a) Do not store a spare LP-gas cylinder near this fireplace. (b) Never fill the cylinder beyond 80 percent full. 24inches (c) Ifthe information in"(a)" and "(b)" is not followed exactly, a fire causing death or serious injury may occur. FOR YOUR SAFETY 1. Do not store or use gasoline or other flammable material and liquids in the vicinity of this fireplace or other appliance. 2. ALP cylinder not connected for use must not be stored inthe vi
Summary of the content on the page No. 4
LP gas tanks must be stored outdoors in a well- IMPORTANT; Your Homestead patio fireplace cannot ventilated area and out of the reach of children. be converted to use Natural Gas. Attempting to do so is Disconnected LP gas tanks must not be stored in a extremely hazardous and wilt also void the warranty. building, garage or any other enclosed area. Correct LP Gas Tank Use When your fireplace is not in use the gas must be The patio fireplace is designed for use with a standard turned off at the g
Summary of the content on the page No. 5
Thefollowing tableillustrates a breakdown of thehardware pack.It highlights whichcomponents areusedinthe various stages ofassembly. Ref. No. Component Qty. Usage Assemble the Screen onto Base $115G03082 Screw, 3/16"-24 UNC 4 Assemble the Lid onto Screen $115G03082 Screw, 3/16"-24 UNC 4 $115G03082 Screw, 3/16"-24 UNC 16 Assemble Screen $313G03062 Nut, 3/16"-24 UNC 16 Assemble Screen Screw, 3/16"-24 UNC Qty. 24 Parts # $115G03082 © Nut, 3/16"-24 UNC Qty. 16 Parts # $313G03062 For complete installa
Summary of the content on the page No. 6
1.Lid 2.Screen 11.Burner Base 3.LogSet 4. ClinkerSet 5.Ember Glow 6.Carrier Assembly 7.Control PanelBox 8.Caster Shaft 9.Caster withwelded 12.PilotAssembly 13.Burner 10.Remote Control ,_ 22.Control BoxDoor 16.ElectricI yCompartment andElectric Wire) 17.AirFilter 23.BatteryCover 18.Orifice withNut 24.Control BoxDoorLock 19.Control Assembly Y" (Includes Valve Assembly, i 25.Knob/Control Box Control Box andWire Set) _" 26.TankFixingBracket 20.BurnerExtens 27.TankFixingPlate 21.PilotGasTube 28.Front
Summary of the content on the page No. 7
Ref # Description Part # Qty. 1 Lid PC3800005F 1 2 Screen PC3700002F 4 3 Log Set (3 pieces) PC1500000M 1 4 Clinker Set (30 pieces) PC1600000G 1 5 Ember Glow (1 pack) PC1700000G 1 6 Carrier Assembly PC3901000P 1 7 Control Panel Box PC0711000E 1 8 Caster Shaft PC6001000F 1 9 Caster with Welded Seat PC4701000F 1 10 Remote Control PC2011000E 1 11 Burner Base PC6211000F 1 12 Pilot Assembly PC0811000F 1 13 Burner PC1300000A 1 14 Log Supporter PC5301000F 4 15 Burner Plate PC640O000F 1 16 Electric Ignit
Summary of the content on the page No. 8
CAUTION: Whileit is possible for one person to assemble this fireplace, obtain assistance from another person when handling some of the larger, heavier pieces, especially base assembly. Before assembling the fireplace, use the parts list to check that all necessary parts have been included. Inspect the fireplace for damage as you proceed. Do not assemble or operate the fireplace if it appears damaged. If you have questions during the assembly process call 1-888-317-7642. Remove all parts and har
Summary of the content on the page No. 9
H Arrange the Log Set on the Base assembly 1. See _ Position the Log-A on the Log Supporters-c and d, then hold a branch of Log-A by a finger. 2. See _ Position the Log-B on the Log Supporter-b, and hold branch of LogsAand B by finger. 3. See _ Position the Log-C on the Log Supporter-a. NOTE: Keep space in the center between each Log for rising flame. 4. See _ Place the Clinkers evenly around the burner. 5. See _ Place the Ember Glow Chips over the burner plate. Log Suppo_er-_ .... Log Suppo_er*
Summary of the content on the page No. 10
Quick k co ,p,,o0 Tank Fixing Lever Counter clockwise Tank Fixing Bracket to unlock Clockwise to,ock °I El Recheck the Log Set and assemble the Lid 1. Recheck the Log Set, Clinker and Embers to be sure that they are positioned properly. 2. Align the 4 holes in the Lid with the 4 holes at the screen assembly. Fix firmly by using four screws provided. See mL'_l_l I _ t.'i i Screw 3/16"-24 UNC Qty. 4 Ref. #$115G03082 El To install or replace the Batteries 1. Open the Rear Door, turn Locker counter
Summary of the content on the page No. 11
Congratulations Your LP Patio Fireplace is now ready for use. Before the first use and at the beginning of each season (and whenever the LP gas tank has been changed): 1. Read all safety, Lighting and operating instructions. 2. CheckGasValveOdfices, BumerTubeforanyobstructions. 3. Perform gasleakcheckaccording toinstructionsfound on page 11ofthis manual. Never test for leaks with a flame. Prior to the first use, at Note : At first use the housing may emit a slight odor and smoke due to the burn
Summary of the content on the page No. 12
B. Turning the fireplace off Trouble Shooting Press ON/OFF button to turn fireplace off. Close valve on gas tank and close Door. Note: If the fireplace does not turn off by pressing the m ON/OFF button, close the manual valve on the main gas Remedy line. Have the fireplace checked by a qualified service \ technician. \ \ \ \ Retry Ignition Strongwind X C. Operating Remote Control Dead Battery X Replace Batteries TO turn the fireplace on: Airin gas line Purge air Open Door and slowly open valve o
Summary of the content on the page No. 13
f [] M ×/Mi S ttin VR Bakery Case Status _ Indicator _ DOWN Bu_on Thermal - Fuse 127'C/260'F Remarks 1. Color Table BK : black BR : brown R : red O : orange Y : yellow G : green BL : blue 2. Draw based on I I Component Side I I Servo Motor Assembly Chassis _ //// Thermocouple GND =- If any original wires supplied with the appliance must be replaced, it must be replaced with type 18AWG n 600V 105 'C wire or its equivalent. ] Control PCB ON/OFF UR DOWN Switch & Status indicator ] * Remote Control_
Summary of the content on the page No. 14
Model No. 89795 Gas Control Electronic Control with Micro-Processor Gas Input 41,000 BTU!hr Used Gas Liquid Propane Gas "14 "W.C. Max. inlet pressure "11 "W.C. Min. inlet pressure 9 "W.C. Manifold pressure #47 Main injector size Gas Inlet 5/8"-18 UNF Burner Cast - Iron Ring Burner Ignitor Electronic Spark 4 Batteries/D, 6 VDC Electrical Supply * After tank regulator Includes Remote Control Battery type for Remote control: Alkaline type MS21/MN21 size 23At12V Diameter of Lid : 28.9 inches : 25.3
Summary of the content on the page No. 15
110 mm f -_ Electric Wire Diagram Ballery Case E E Ren_arks o 1 Color Table BK : black BR : brown R : red O : oraP_ge Y : yellow G : green BL : blue 2 Draw based on Component Side * Optional Part Servo Motor Assembly Chassis7_ Thermocouple GND If any original wires supplied with the appliance must be replaced, it must be replaced with type 18AWG, 600V, 105 'C wire or its equivalent. PC3011000L * All Text • black color bottom • PANTONE 427 C
Summary of the content on the page No. 16
il meswad Model No. '........ 89795 4 Batteries/D Input Rating for control Gas Type Liquid Propane/LPG 41,000 Btu/hr Gas Input(Max.) "14 "W.C. Gas Inlet Pressure(Max.) "11 "W.C. Gas Inlet pressure(Min.) Manifold Pressure 9 "WC. #47 Injector size Gas Inlet 5!8" - 18 UNF * After tank requiator. SerialNo. I Lot No, L ® U_ IASU.S. 4-96 Outdoor Gas Fireplace. Made in China Used gas: Liquid Propane Only WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury, de