Fyrnetics PE120 user manual

User manual for the device Fyrnetics PE120

Device: Fyrnetics PE120
Category: Smoke Alarm
Manufacturer: Fyrnetics
Size: 0.13 MB
Added : 6/21/2013
Number of pages: 6
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Fyrnetics PE120. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Fyrnetics PE120.

For your convenience

If looking through the Fyrnetics PE120 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Fyrnetics PE120 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Fyrnetics PE120 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Fyrnetics PE120 User manual - Online PDF
Advertisement
« Page 1 of 6 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Fyrnetics PE120 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Fyrnetics PE120. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

PHOTOELECTRIC SMOKE AND FIRE ALARM
USER’S GUIDE
MODEL PE120
A.C. Wire-in Single and/or Multiple Station (24 units maximum)
Photoelectric Smoke Alarm with 9 Volt Battery Back Up
Thank you for purchasing this Fyrnetics smoke and fire alarm. It is an
important part of your family’s home safety plan. You can trust
Fyrnetics to provide the highest quality safety products. We know you
expect nothing less when the lives of your family are at stake.
For your convenience, write down the following inf

Summary of the content on the page No. 2

WARNING! REMOVAL OF THE SMOKE ALARM BATTERY AND DISCONNECTING OR LOSS SINGLE FLOOR PLAN OF A.C. POWER WILL RENDER THE SMOKE ALARM INOPERATIVE. ELECTRICAL RATING: 120 VAC, 60HZ, 80mA maximum per detector (maximum 80mA for originat- ing unit with 24 alarms interconnected). IMPORTANT! READ ALL INSTRUCTIONS BEFORE INSTALLATION AND KEEP THIS MANUAL NEAR THE ALARM FOR FUTURE REFERENCE. CONTENTS OF THIS MANUAL MULTIPLE FLOOR PLAN 1 -- RECOMMENDED LOCATIONS FOR SMOKE ALARMS 2 -- LOCATIONS TO AVOID 3 --

Summary of the content on the page No. 3

2. LOCATIONS TO AVOID Alarms must not be located within 3 feet of the following: • Supply and return registers used for forced air heating and air conditioning. •Ceiling fans and other high air flow areas. •Bathrooms which contain a tub or shower. In general, alarms should not be located: •In the garage. Products of combustion are present when you start your automobile. •In an area where the temperature may fall below 40ºF or rise above 100ºF. •In dusty areas. Dust particles may cause nuisance

Summary of the content on the page No. 4

8. Turn on the A.C. power. The green A.C. Power On Indicator should be lit when the alarm is FLASHING LED LIGHT: This smoke alarm is equipped with a flashing red indicator LED. The LED operating from A.C. power. is located under the test button and has three modes of operation. FIGURE 2. SELECT CORRECT MOUNTING HOLES ON TRIM RING Standby Condition The red LED will flash every 30-40 seconds to indicate that the smoke alarm is operating properly. Alarm Condition When the alarm senses products o

Summary of the content on the page No. 5

To replace the battery, remove the alarm from the trim ring by rotating the alarm in the direction of •Smoke alarms are devices that can provide early warning of possible fires at a reasonable cost; the “OFF” arrow on the cover (see Section 3, Figure 4) To discon- however, alarms have sensing limitations. Ionization type alarms offer a broad range of fire nect the A.C. power harness, squeeze the locking arms on the sensing capabilities but are better at detecting fast flaming fires than slow sm

Summary of the content on the page No. 6

•Don’t return to your home until the fire officials say that it is all right to do so. FIVE YEAR LIMITED WARRANTY There are situations where a smoke alarm may not be effective to protect against fire as stated in the NFPA Standard 72. For instance: Fyrnetics warrants to the original purchaser that the enclosed smoke alarm (but not the bat- tery) will be free from defects in material and workmanship or design under normal use and a) smoking in bed service for a period of five years from the date


Alternative user manuals
# User manual Category Download
1 Fyrnetics PE9 User manual Smoke Alarm 1
2 Adobe CS3 User manual Smoke Alarm 1
3 ADT Security Services ADT-LCD40 User manual Smoke Alarm 6
4 ADT Security Services Safewatch Pro 2000 User manual Smoke Alarm 5
5 ADT Security Services SAVS20ADT-1 User manual Smoke Alarm 3
6 ADT Security Services Unimode 9600 User manual Smoke Alarm 7
7 ADT Security Services SAVS20ADTG User manual Smoke Alarm 4
8 Aico Ei166RC User manual Smoke Alarm 12
9 Aico Carbon Monoxide Alarm Ei 225EN User manual Smoke Alarm 40
10 Aico Ei161RC User manual Smoke Alarm 5
11 Aico Ei169RF User manual Smoke Alarm 1
12 Aico Ei168RC User manual Smoke Alarm 14
13 Aico Carbon Monoxide Alarms 260 Series User manual Smoke Alarm 0
14 Aico Carbon Monoxide Alarm Ei 220EN User manual Smoke Alarm 0
15 Aico Ei164RC User manual Smoke Alarm 5