FMI FVF18P user manual

User manual for the device FMI FVF18P

Device: FMI FVF18P
Category: Gas Heater
Manufacturer: FMI
Size: 0.43 MB
Added : 9/13/2013
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for FMI FVF18P. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with FMI FVF18P.

For your convenience

If looking through the FMI FVF18P user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual FMI FVF18P on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual FMI FVF18P to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
FMI FVF18P User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual FMI FVF18P but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to FMI FVF18P. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

UNVENTED (VENT-FREE)
PROPANE/LP GAS LOG HEATER
ALSO DESIGN-CERTIFIED AS A VENTED DECORATIVE APPLIANCE
OWNER’S OPERATION AND INSTALLATION MANUAL
Heat Majic™
Models FVF18P,
FVF24P, and
FVF30P
Patent Pending
18", 24" and 30" Variable
Manually-Controlled Models
WARNING: Improper installation, adjust-
WARNING: If the information in this manual is
ment, alteration, service, or maintenance
not followed exactly, a fire or explosion may
can cause injury or property damage.
result causing property damage,

Summary of the content on the page No. 2

UNVENTED PROPANE/LP GAS LOG HEATER 4. If you smell gas SAFETY WARNING: Do not use a • shut off gas supply blower insert, heat exchanger INFORMATION • do not try to light any appliance insert or other accessory not ap- • do not touch any electrical switch; do proved for use with this heater. not use any phone in your building WARNINGS WARNING ICON G 001 • immediately call your gas supplier Due to high temperatures, the from a neighbor’s phone. Follow the IMPORTANT: Read this owner’s appliance s

Summary of the content on the page No. 3

OWNER’S MANUAL 14. Do not use this heater to cook food or SAFETY PRODUCT burn paper or other objects. INFORMATION FEATURES 15. Do not use heater if any part has been Continued exposed to or under water. Immediately OPERATION call a qualified service technician to in- 12. This heater needs fresh, outside air ven- spect the room heater and to replace any This heater is clean burning. It requires no tilation to run properly. This heater has part of the control system and any gas outside venting. Th

Summary of the content on the page No. 4

UNVENTED PROPANE/LP GAS LOG HEATER Confined and Unconfined Space PROVIDING ADEQUATE AIR FOR VENTILATION The National Fuel Gas Code ANSI Z223.1/ COMBUSTION AND NFPA 54 defines a confined space as a The following are excerpts from Na- VENTILATION space whose volume is less than 50 cubic tional Fuel Gas Code, ANSI Z223.1/ 3 feet per 1,000 Btu per hour (4.8 m per kw) NFPA 54, Section 5.3, Air for Combus- of the aggregate input rating of all appli- tion and Ventilation. WARNING: This heater shall an

Summary of the content on the page No. 5

OWNER’S MANUAL AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width x Height = _________________cu.

Summary of the content on the page No. 6

UNVENTED PROPANE/LP GAS LOG HEATER AIR FOR 12" COMBUSTION AND VENTILATION Ventilation Continued Ventilation Grills Grills Into Adjoining Room, VENTILATION AIR Into Adjoining Or Option 2 Room, Remove Ventilation Air From Inside Option 1 Door into Building Adjoining This fresh air would come from an adjoining Room, unconfined space. When ventilating to an Option adjoining unconfined space, you must pro- 3 vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor

Summary of the content on the page No. 7

OWNER’S MANUAL INSTALLATION MINIMUM FIREPLACE WARNING: Never install the CLEARANCE TO heater NOTICE: This heater is intended COMBUSTIBLE MATERIALS • in a bedroom or bathroom un- for use as supplemental heat. less installed as a vented ap- Log Size Side Wall Ceiling Use this heater along with your pliance (see page 10) primary heating system. Do not 18", 24", 16" 42" • in a recreational vehicle install this heater as your pri- and 30" • where curtains, furniture, mary heat source. If you have a

Summary of the content on the page No. 8

UNVENTED PROPANE/LP GAS LOG HEATER If Using Mantel if noncombustible material is more than INSTALLATION 12", you may need the hood accessory to You must have noncombustible material(s) Continued deflect heat away from your mantel shelf. above the fireplace opening. Noncombus- See Figure 5 and Figures 6 and 7 on page 9 tible materials (such as slate, marble, tile, NOTICE: Manual control heaters for minimum clearances. etc.) must be at least 1/2 inch thick. With may be used as a vented product. sh

Summary of the content on the page No. 9

OWNER’S MANUAL INSTALLATION Mantel Shelf 10" Underside of Continued 8" Mantel Shelf 6" MANTEL CLEARANCES 1 2 /2" In addition to meeting noncombustible mate- rial clearances, you must also meet required All minimum distances are clearances between fireplace opening and in inches mantel shelf. If you do not meet the clear- Minimum Non- ances listed below, you will need a hood. (A) Combustible Log Set Material 12" 18" 20" 22" 24" 24"/30" Models Determining Minimum Mantel 8" 8" 14" 17" 20" 18" M

Summary of the content on the page No. 10

UNVENTED PROPANE/LP GAS LOG HEATER See chart below for minimum permanent INSTALLING HEATER BASE INSTALLATION flue opening you must provide. Attach ASSEMBLY Continued damper clamp so the minimum permanent flue opening will be maintained at all times. INSTALLING DAMPER WARNING: You must secure CLAMP ACCESSORY FOR this heater to fireplace floor. If Chimney Minimum Permanent VENTED OPERATION not, heater will move when you Height (ft.) Flue Opening (sq. ins.) adjust controls. Moving heater Note: Whe

Summary of the content on the page No. 11

OWNER’S MANUAL INSTALLATION Heater Gas Continued Regulator Installation Items Needed • hardware package (provided with heater) Fitting • approved flexible gas hose (not provided) Flexible Gas Hose (if allowed by local codes) (if allowed by local • sealant (resistant to propane/LP gas, not codes) provided) • electric drill with 3/16" drill bit (metal Figure 11 - Attaching Flexible Gas Hose to Heater Gas Regulator or masonry as applicable) • flathead screwdriver 1. Apply pipe joint sealant lightly

Summary of the content on the page No. 12

UNVENTED PROPANE/LP GAS LOG HEATER External Regulator Installation must include a equipment shutoff INSTALLATION Propane/LP valve, union, and plugged 1/8" NPT tap. Continued Supply Tank Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from CONNECTING TO GAS heater (see Figure 14). SUPPLY IMPORTANT: Install equipment shutoff valve in an accessible location. The equip- WARNING: A qualified ser- ment shutoff valve is for turning on or vice person must connect heater shu

Summary of the content on the page No. 13

OWNER’S MANUAL Test Pressures Equal To or Less Than Pressure Testing Heater Gas INSTALLATION 1/2 PSIG (3.5 kPa) Connections Continued 1. Close equipment shutoff valve (see Fig- 1. Open equipment shutoff valve (see Fig- ure 15). CHECKING GAS ure 15). 2. Pressurize supply piping system by ei- CONNECTIONS 2. Open propane/LP supply tank valve. ther using compressed air or opening 3. Make sure control knob of heater is in propane/LP supply tank valve. the OFF position. WARNING: Test all gas pip- 3.

Summary of the content on the page No. 14

UNVENTED PROPANE/LP GAS LOG HEATER One Piece INSTALLATION Log Set Continued INSTALLING LOGS WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. CAUTION: After installation and periodically thereafter, check to ensure that no flame comes in contact with any log. With the heater set to High, check to see if Burner flames contact any log. If so, re- Chassis "U

Summary of the content on the page No. 15

OWNER’S MANUAL 4. Wait five (5) minutes to clear out any LIGHTING OPERATING gas. Then smell for gas, including INSTRUCTIONS HEATER near the floor. If you smell gas, STOP! Follow “B” in the safety in- FOR YOUR SAFETY WARNING: formation in column 1. If you don’t • If fireplace has glass doors, READ BEFORE smell gas, go to the next step. never operate this heater with LIGHTING 5. Slightly depress and turn control glass doors closed. If you oper- knob counterclockwise to C-clockwise ate heater with

Summary of the content on the page No. 16

UNVENTED PROPANE/LP GAS LOG HEATER BURNER PRIMARY AIR OPERATING INSPECTING HOLES HEATER BURNERS Air is drawn into the burner through the Continued Check pilot flame pattern and burner flame holes in the fitting at the burner entrance. patterns often. VARIABLE CONTROL These holes may become blocked with dust or lint. Periodically inspect these holes for OPERATION PILOT FLAME PATTERN any blockage and clean if needed. Blocked The variable control valve can be set to Figure 21 shows a correct pilot

Summary of the content on the page No. 17

OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off and un- CAUTION: Never use a wire, plug heater and let cool before needle, or similar object to clean Note: For additional help, visit DESA servicing. Only a qualified ser- ODS/pilot. This can damage ODS/ International’s Technical Service web vice person should service and pilot unit. site at www.desatech.com. repair heater. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When ignitor butto

Summary of the content on the page No. 18

UNVENTED PROPANE/LP GAS LOG HEATER TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Burner does not light after ODS/pilot is lit 1. Inlet gas pressure is too low 1. Contact local propane/LP gas company 2. Burner orifice clogged 2. Clean burner (see Cleaning and Mainte- nance, page 20) or replace burner orifice 3. Burner orifice diameter is too small 3. Replace burner orifice Delayed ignition burner 1. Manifold pressure is too low 1. Contact local propane/LP gas company 2. Burner

Summary of the content on the page No. 19

OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette

Summary of the content on the page No. 20

UNVENTED PROPANE/LP GAS LOG HEATER 4. Check the injector holder located at the LOGS CLEANING AND end of the burner tube again. Remove • If you remove logs for cleaning, refer to MAINTENANCE any large particles of dust, dirt, lint, or Installing Logs, page 14, to properly re- pet hair with a soft cloth or vacuum place logs. cleaner nozzle. WARNING: Turn off heater • Replace log(s) if broken or chipped 5. Blow air into the primary air holes on and let cool before cleaning. (dime-sized or larger).


Alternative user manuals
# User manual Category Download
1 FMI FVF24P User manual Gas Heater 0
2 FMI FVF30P User manual Gas Heater 0
3 FMI GL36ST User manual Gas Heater 2
4 FMI FVF18PW User manual Gas Heater 0
5 FMI CCL3924PTA/NTA User manual Gas Heater 2
6 FMI GL36STEP User manual Gas Heater 1
7 FMI FVF30PW User manual Gas Heater 0
8 FMI FLAME-MAX FVFM27NR User manual Gas Heater 0
9 FMI FVF24PW User manual Gas Heater 0
10 FMI GL36STP User manual Gas Heater 0
11 FMI GL36STE User manual Gas Heater 0
12 FMI PFS US GWRN18TC User manual Gas Heater 0
13 FMI PFS US GWRN18C User manual Gas Heater 0
14 FMI PFS US GWRN30TC User manual Gas Heater 0
15 FMI PFS US GWRP26C User manual Gas Heater 0
16 Allied Air Enterprises 506271-01 User manual Gas Heater 0
17 Blue Rhino ALL WEATHER WOVEN HEATER GWU9850F / 35554 User manual Gas Heater 2
18 Breckwell ECONOMY P22FSL User manual Gas Heater 0
19 Breckwell ECONOMY P22FSA User manual Gas Heater 0
20 Breckwell ECONOMY P22I User manual Gas Heater 1