Firex Model PB user manual

User manual for the device Firex Model PB

Device: Firex Model PB
Category: Smoke Alarm
Manufacturer: Firex
Size: 0.29 MB
Added : 4/1/2014
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Firex Model PB. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Firex Model PB.

For your convenience

If looking through the Firex Model PB user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Firex Model PB on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Firex Model PB to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Firex Model PB User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Firex Model PB but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Firex Model PB. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

110-644 10/5/00 2:17 PM Page 1
©1998 Maple Chase Company
Battery
Operated
®
Smoke Alarm
110-644
MODELS A, B, C,
E AND PB
PLEASE READ AND SAVE
THIS MANUAL
Installer: Please leave this
manual with the product.
!WARNING: THIS SMOKE ALARM WILL SOUND A SHORT BEEP WHEN POWER IS CONNECTED.
DO NOT USE THIS SMOKE ALARM WITH ANY EXTERNAL BUG SCREENS OR SMOKE ALARM
GUARDS. USE OF THESE TYPES OF DEVICES MAY REDUCE SMOKE ALARM RESPONSE TIME.
CONTENTS
p.1-2 IMPORTANT INFORMATION ABOUT YOUR SMOKE ALARM
p.

Summary of the content on the page No. 2

110-644 10/5/00 2:17 PM Page 2 • Smoke alarms cannot give you an early warning of fire or smoke unless you install, use and maintain them by following these instructions. • You must hear the alarm’s warning sound and quickly respond to it to reduce the risk of damage, injury or death that may result from a fire. • Your smoke alarm is packaged with the battery disconnected. Connect it to the battery leads before mounting the smoke alarm. • A smoke alarm will not work without a good battery ins

Summary of the content on the page No. 3

110-644 10/5/00 2:17 PM Page 3 You should use both battery-powered and direct-wired 120-volt AC-powered smoke alarms. Since A SMOKE ALARM WILL NOT WORK WITHOUT POWER, having alarms that will work from two different power sources can give you extra protection in case of a dead battery, or an AC power failure. Using a smoke alarm in a smoky area like a kitchen, or in a high humidity area near a shower, can cause false alarms. DO NOT REMOVE YOUR BATTERY TO QUIET THE ALARM. DO NOT TAKE THE ALARM

Summary of the content on the page No. 4

110-644 10/5/00 2:17 PM Page 4 BEDROOM DINING BEDROOM BEDROOM KITCHEN DINING ROOM FAMILY ROOM KITCHEN ROOM LIVING ROOM BEDROOM DENOTES SMOKE ALARM WITH FALSE ALARM CONTROL BEDROOM DENOTES SMOKE ALARM LIVING ROOM BEDROOM FIGURE 1 FIGURE 2 IF YOUR HOUSEHOLD OR RESIDENCE HAS SEVERAL FLOORS, THERE MUST BE AN ALARM ON EVERY FLOOR, INCLUDING IN THE BASEMENT. See Figure 3. • Do install a smoke alarm in every bedroom where a smoker sleeps. • Do install a smoke alarm in every room and bedroom wher

Summary of the content on the page No. 5

110-644 10/5/00 2:17 PM Page 5 • If you have a peaked, sloped, gabled or cathedral-style ceiling, mount your smoke alarm 4 to 36 inches (3 feet) MEASURED HORIZONTALLY FROM THE HIGHEST POINT ON THE CEILING, as shown in Figure 4. • Do install smoke alarms in both rooms (areas) that are divided by a partial wall extending 8 or more inches down from the ceiling. See smoke alarms located in rooms B and C in Figure 4. SPECIAL DIRECTIONS FOR INSTALLING YOUR SMOKE ALARM IN MANUFACTURED AND MOBILE H

Summary of the content on the page No. 6

110-644 10/5/00 2:17 PM Page 6 IMPORTANT INFORMATION SMOKE ALARM SAFETY CHECKLIST PIN THIS UP CLOSE TO YOUR SMOKE ALARM IN AN EASY-TO-READ LOCATION AND REVIEW BOTH SIDES OFTEN Before installing, using and maintaining your smoke alarm read the entire Owner’s Manual and Warranty, and keep it in a convenient location for reference. 1. Test your smoke alarm every week. To test the electronics, firmly depress the button. To test that smoke reaches the sensor, blow smoke in a careful fire-safe ma

Summary of the content on the page No. 7

110-644 10/5/00 2:17 PM Page 7 OTHER THINGS YOU CAN DO TO MAKE YOUR FAMILY AND HOME SAFER FROM FIRES Installing, testing and taking care of smoke alarms is just one step in helping to protect your family and home from fires. You must also reduce the chance that fire will start in your home and increase your chances of escaping if one does start. For your safety, at a minimum, you should do the following to have a more effective fire safety program. A. FOLLOW SAFETY RULES AND PREVENT HAZARDOUS

Summary of the content on the page No. 8

110-644 10/5/00 2:17 PM Page 8 Continued from page 5 • Do not install a smoke alarm in dusty or dirty areas; SUCH AN INSTAL- LATION CANNOT BE RELIED UPON. An accumulation of dust and dirt in the sensing chamber may block the openings and prevent an alarm, or may get inside the alarm and cause false alarms. If a smoke alarm is required in such an area, vacuum it frequently and test it according to the section “TAKING CARE OF YOUR SMOKE ALARM.” • Do not install a smoke alarm in the dead air spa

Summary of the content on the page No. 9

110-644 10/5/00 2:17 PM Page 9 second while the button is being pushed and the alarm is sounding. The smoke alarm will stop sounding when you release the button. 2. If your smoke alarm has the False Alarm Control or Safety Light feature see “SPECIAL SMOKE ALARM FEATURES” for further testing information. 3. IMPORTANT: Always test your smoke alarm upon returning from vacation, or any other time when no one has been in your household or residence for several days. 4. If a smoke alarm is install

Summary of the content on the page No. 10

110-644 10/5/00 2:17 PM Page 10 5. Test smoke alarm for proper operation (see ”WEEKLY TESTING OF YOUR SMOKE ALARM” section). The smoke alarm operates on a 9-volt battery. The normal battery operating life will be one (1) year. The life of some batteries may be less. 6. Firex smoke alarms sold with Ultralife long-life lithium batteries require replacement approximately every ten (10) years. Replace the battery approximately every ten (10) years or when the low battery signal sounds. !CAUTION

Summary of the content on the page No. 11

110-644 10/5/00 2:17 PM Page 11 SPECIAL SMOKE ALARM FEATURES If your smoke alarm has one or more of these special features, read the following: • BLINKING LED LIGHT (Models B, C, E and PB): The indicator light under the Push-to-Test button blinks about once per minute to indicate the smoke alarm is receiving power. • FALSE ALARM CONTROL (Model C): Simply push the test button to temporarily silence the smoke alarm if a nuisance alarm occurs or to prevent nuisance alarms. By momentarily depress

Summary of the content on the page No. 12

110-644 10/5/00 2:17 PM Page 12 WARRANTY INFORMATION 5-YEAR LIMITED SMOKE ALARM WARRANTY AND 10-YEAR LIMITED ULTRALIFE U9VL-J LITHIUM BATTERY WARRANTY (WHEN SOLD WITH MAPLE CHASE COMPANY SMOKE ALARM) Maple Chase Company warrants to the original consumer purchaser each new smoke alarm to be free from defects in material and workmanship under normal use and service for a period of five (5) years from the date of purchase. For Maple Chase Company smoke alarms sold with an Ultralife U9VL-J 9-vo


Alternative user manuals
# User manual Category Download
1 Firex 242 User manual Smoke Alarm 18
2 Firex 2650-660 User manual Smoke Alarm 5
3 Firex 2650-661 User manual Smoke Alarm 1
4 Firex 45189 User manual Smoke Alarm 2
5 Firex 243 User manual Smoke Alarm 0
6 Firex 5700 User manual Smoke Alarm 0
7 Firex 4480 User manual Smoke Alarm 6
8 Firex 480 User manual Smoke Alarm 3
9 Firex 484 User manual Smoke Alarm 1
10 Firex 592SC User manual Smoke Alarm 1
11 Firex 591S User manual Smoke Alarm 1
12 Firex ADC User manual Smoke Alarm 0
13 Firex A User manual Smoke Alarm 0
14 Firex AD User manual Smoke Alarm 5
15 Firex C User manual Smoke Alarm 1
16 Adobe CS3 User manual Smoke Alarm 1
17 ADT Security Services ADT-LCD40 User manual Smoke Alarm 6
18 ADT Security Services Safewatch Pro 2000 User manual Smoke Alarm 5
19 ADT Security Services SAVS20ADT-1 User manual Smoke Alarm 3
20 ADT Security Services Unimode 9600 User manual Smoke Alarm 7