Firex i4618 user manual

User manual for the device Firex i4618

Device: Firex i4618
Category: Smoke Alarm
Manufacturer: Firex
Size: 0.44 MB
Added : 4/7/2014
Number of pages: 18
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Firex i4618. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Firex i4618.

For your convenience

If looking through the Firex i4618 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Firex i4618 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Firex i4618 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Firex i4618 User manual - Online PDF
Advertisement
« Page 1 of 18 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Firex i4618 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Firex i4618. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

1261-7201-00(820-1552A) .qxd:_ 2008.10.10 11:37 AM Page 1
SIGNALING
U
L
LISTED
Smoke Alarm
User’s Guide
i4618, i4718, i5000 Series
Model: i4618
� 120 Volt Smoke Alarm with 9 Volt Battery Back-up
� Front Load Battery
®
� Test and Hush Button
ATTENTION: Please take a few minutes to thoroughly read this
user’s guide which should be saved for future reference and
passed on to any subsequent owner.
Manual P/N 820-1552 Rev. A 1261-7201-00

Summary of the content on the page No. 2

1261-7201-00(820-1552A) .qxd:_ 2008.10.10 11:37 AM Page 2 What to do When the Alarm Sounds! Smoke Alarm Procedure NEVER IGNORE THE SOUND OF THE ALARM! Smoke alarms are designed to minimize false alarms. Cigarette smoke will not normally set off the alarm, unless the smoke is blown directly into the alarm. Combustion particles from cook- ing may set off the alarm if it is located too close to the cook- ing area. Large quantities of combustion particles are generat- ed from spills or when broil

Summary of the content on the page No. 3

1261-7201-00(820-1552A) .qxd:_ 2008.10.10 11:37 AM Page 3 A.C. Wire-in Single and/or Multiple Station (up to 24 Devices) Ionization TM Smoke Alarm with 9 Volt Battery Back Up and SMART HUSH Control to temporarily silence nuisance alarms. Thank you for purchasing this smoke alarm. It is an important part of your family’s home safety plan. You can trust this product to provide the highest quality safety protection. We know you expect nothing less when the lives of your family are at stake. Fire

Summary of the content on the page No. 4

1261-7201-00(820-1552A) .qxd:_ 2008.10.10 11:37 AM Page 4 WARNING! REMOVAL OF THE SMOKE ALARM BATTERY AND DISCONNECT- ING or LOSS OF A.C. POWER WILL RENDER THE SMOKE ALARM INOPERATIVE. ELECTRICAL RATING: 120 VAC, 60HZ, 80mA maximum per alarm (maximum 80mA for originating unit with 24 devices interconnected). 1. RECOMMENDED LOCATIONS FOR ALARMS � Locate the first alarm in the immediate area of the bedrooms. Try to monitor the exit path as the bedrooms are usually farthest from the exit. If mor

Summary of the content on the page No. 5

1261-7201-00(820-1552A) .qxd:_ 2008.10.10 11:37 AM Page 5 � Install Smoke Alarms on tray-shaped ceilings (coffered ceilings) on the highest portion of the ceiling or on the sloped portion of the ceiling within 12” (305mm) verti- cally down from the highest point (see figure 4). MOBILE HOME INSTALLATION Modern mobile homes have been designed and built to be energy efficient. Install smoke alarms as recom- FIGURE 1 mended above (refer to RECOMMENDED LOCATIONS and FIGURES 1 and 2). In older mob

Summary of the content on the page No. 6

1261-7201-00(820-1552A) .qxd:_ 2008.10.10 11:37 AM Page 6 � In dusty areas. Dust particles may cause nuisance alarm or failure to alarm. � In very humid areas. Moisture or steam can cause nuisance alarms. � In insect-infested areas. � Smoke alarms should not be installed within 3 ft (.9m) of the following: the door to a kitchen, the door to a bathroom containing a tub or shower, forced air supply ducts used for heating or cooling, ceiling or whole house ventilating fans, or other high air flo

Summary of the content on the page No. 7

1261-7201-00(820-1552A) .qxd:_ 2008.10.10 11:37 AM Page 7 � A maximum of 24 Kidde and/or FireX devices may be interconnected in a mul- tiple station arrangement. The interconnect system should not exceed the NFPA interconnect limit of 12 smoke alarms and/or 18 alarms total (smoke, heat, carbon monoxide, etc.). With 18 alarms interconnected, it is still possi- ble to interconnect up to a total of 6 remote signaling devices and/or relay modules. � When mixing models which have battery backup

Summary of the content on the page No. 8

1261-7201-00(820-1552A) .qxd:_ 2008.10.10 11:37 AM Page 8 BATTERY INSTALLATION See MAINTENANCE (Section 6) for battery installation. CAUTION! THIS UNIT WILL NOT FUNCTION WITHOUT A PROPERLY INSTALLED BATTERY, AND IS EQUIPPED WITH A BATTERY LOCKOUT FEA- TURE WHICH PREVENTS THE BATTERY DOOR FROM CLOSING IF A BAT- TERY IS NOT INSTALLED CORRECTLY. MOUNTING INSTRUCTIONS CAUTION: THIS UNIT IS SEALED. THE COVER IS NOT REMOVABLE! 1. Remove the trim ring from the back of the alarm by holding the trim r

Summary of the content on the page No. 9

1261-7201-00(820-1552A) .qxd:_ 2008.10.10 11:37 AM Page 9 NOTE: The alarm will mount to the bracket in 4 positions (every 90 degrees). When wall mounting, make sure the battery box is at the bottom of the unit. (see Figure 5). 6. Pull the Battery Pull Tab (red tab protruding from the unit) completely out of the unit unit and slide the battery door completely closed. This will automatically connect the battery. 7. Test the unit to ensure proper operation by pressing the Test/Hush Button for a

Summary of the content on the page No. 10

1261-7201-00(820-1552A) .qxd:_ 2008.10.10 11:37 AM Page 10 4. OPERATION AND TESTING OPERATION: The smoke alarm is operating once A.C. power is applied, fresh batteries are installed and testing is complete. When the smoke alarm ionization chamber senses products of combustion, the horn will sound a loud (85db) tem- poral alarm until the sensing chamber is cleared of smoke particles. TM SMART HUSH CONTROL: The “HUSH” feature has the capability of temporarily desensitizing the alarm circuit fo

Summary of the content on the page No. 11

1261-7201-00(820-1552A) .qxd:_ 2008.10.10 11:37 AM Page 11 Alarm Memory: This smoke alarm is equipped with an alarm memory, which provides a visual indication when an alarm has been activated. The red LED will illuminate for about 1.5 seconds every 16 seconds to indicate the memory condition. The memory will remain activated until pushing the Test/Hush Button resets it. The memory will also reset if the battery voltage drops to 8 volts. In an inteconnected installation only the memory

Summary of the content on the page No. 12

1261-7201-00(820-1552A) .qxd:_ 2008.10.10 11:37 AM Page 12 6. MAINTENANCE ALARM REMOVAL IF SMOKE ALARM TAMPER RESIST FEATURE HAS BEEN ACTIVATED, REFER TO SMOKE ALARM TAMPER RESIST FEATURE IN SECTION 3 FOR REMOVAL INSTRUCTIONS. To remove the alarm from the trim ring, rotate the alarm counter clockwise in the direction of the "OFF" arrow on the cover. To disconnect the A.C. power harness, squeeze the locking arms on the sides of the Quick Connector while pulling the connector away from the bott

Summary of the content on the page No. 13

1261-7201-00(820-1552A) .qxd:_ 2008.10.10 11:37 AM Page 13 USE ONLY THE FOLLOWING 9 VOLT BATTERIES FOR SMOKE ALARM REPLACEMENT. Carbon-zinc type EVEREADY 1222; GOLD PEAK 1604P OR 1604S Alkaline type ENERGIZER 522; DURACELL MN1604 OR MX1604; GOLD PEAK 1604A PANASONIC 6AM6, 6AM-6, 6AM-6PI, 6AM6X, AND 6LR61 (GA) Lithium type ULTRALIFE U9VL-J NOTE: WEEKLY TESTING IS REQUIRED! WARNING! BE SURE TO FOLLOW BATTERY INSTALLATION INSTRUCTIONS PRINTED ON THE BACK OF THE ALARM AND USE ONLY THE BATTERIES

Summary of the content on the page No. 14

1261-7201-00(820-1552A) .qxd:_ 2008.10.10 11:37 AM Page 14 reasonable cost; however, alarms have sensing limitations. Ionization sensing alarms may detect invisible fire particles (associated with fast flaming fires) sooner than photoelectric alarms. Photoelectric sensing alarms may detect visi- ble fire particles (associated with slow smoldering fires) sooner than ionization alarms. Home fires develop in different ways and are often unpredictable. For maximum protection, Firex recommends t

Summary of the content on the page No. 15

1261-7201-00(820-1552A) .qxd:_ 2008.10.10 11:37 AM Page 15 � Determine a place outside your home where you all can meet if a fire occurs. � Familiarize everyone with the sound of the smoke alarm and train them to leave your home when they hear it. � Practice a fire drill at least every six months, including fire drills at night. Ensure that small children hear the alarm and wake when it sounds. They must wake up in order to execute the escape plan. Practice allows all occu- pants to test your

Summary of the content on the page No. 16

1261-7201-00(820-1552A) .qxd:_ 2008.10.10 11:37 AM Page 16 Smoke Detection – Are More Smoke Alarms Desirable? The required number of smoke alarms might not provide reliable early warning protection for those areas separated by a door from the areas protected by the required smoke alarms. For this reason, it is recommended that the householder consider the use of addi- tional smoke alarms for those areas for increased protection. The additional areas include the basement, bedrooms, dining r

Summary of the content on the page No. 17

1261-7201-00(820-1552A) .qxd:_ 2008.10.10 11:37 AM Page 17 FIVE YEAR LIMITED WARRANTY (i4618, i4718 Series) Kidde warrants to the original purchaser that the enclosed smoke alarm (but not the battery) will be free from defects in material and workmanship or design under normal use and service for a period of five years from the date of purchase. The obligation of Kidde under this warranty is limited to repairing or replacing the smoke alarm or any part which we find to be defective in materi

Summary of the content on the page No. 18

1261-7201-00(820-1552A) .qxd:_ 2008.10.10 11:37 AM Page 18 TEN YEAR LIMITED WARRANTY (i5000 Series) Kidde warrants to the original purchaser that the enclosed smoke alarm (but not the battery) will be free from defects in material and workmanship or design under normal use and service for a period of ten years from the date of purchase. The obligation of Kidde under this warranty is limited to repairing or replacing the smoke alarm or any part which we find to be defective in material, workm


Alternative user manuals
# User manual Category Download
1 Firex 242 User manual Smoke Alarm 18
2 Firex 2650-660 User manual Smoke Alarm 5
3 Firex 2650-661 User manual Smoke Alarm 1
4 Firex 45189 User manual Smoke Alarm 2
5 Firex 243 User manual Smoke Alarm 0
6 Firex 5700 User manual Smoke Alarm 0
7 Firex 4480 User manual Smoke Alarm 6
8 Firex 480 User manual Smoke Alarm 3
9 Firex 484 User manual Smoke Alarm 1
10 Firex 592SC User manual Smoke Alarm 1
11 Firex 591S User manual Smoke Alarm 1
12 Firex ADC User manual Smoke Alarm 0
13 Firex A User manual Smoke Alarm 0
14 Firex AD User manual Smoke Alarm 5
15 Firex C User manual Smoke Alarm 1
16 Adobe CS3 User manual Smoke Alarm 1
17 ADT Security Services ADT-LCD40 User manual Smoke Alarm 6
18 ADT Security Services Safewatch Pro 2000 User manual Smoke Alarm 5
19 ADT Security Services SAVS20ADT-1 User manual Smoke Alarm 3
20 ADT Security Services Unimode 9600 User manual Smoke Alarm 7