FireplaceXtrordinair 864 HH user manual

User manual for the device FireplaceXtrordinair 864 HH

Device: FireplaceXtrordinair 864 HH
Category: Fire Pit
Manufacturer: FireplaceXtrordinair
Size: 2.24 MB
Added : 7/25/2014
Number of pages: 68
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for FireplaceXtrordinair 864 HH. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with FireplaceXtrordinair 864 HH.

For your convenience

If looking through the FireplaceXtrordinair 864 HH user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual FireplaceXtrordinair 864 HH on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual FireplaceXtrordinair 864 HH to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
FireplaceXtrordinair 864 HH User manual - Online PDF
Advertisement
« Page 1 of 68 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual FireplaceXtrordinair 864 HH but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to FireplaceXtrordinair 864 HH. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

AAAAAAAAAAAAAAAAAAAAAA
864 HH
AAAAAAAAAAAAAAAAAAAAAA
Fireplace
AAAAAAAAAAAAAAAAAAAAAA AAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAA AAAAAAAAA
Featuring the
AAAAAAAAAAAAAAAAAAAAAA AAAAAAAAA
AAAAAAAAAAAAAAAAAAAAAA AAAAAAAAA AAA
Burner
AAAAAAAAAAAAAAAAAAAAAAA AAAAAAAAA AAA

AAAAAAAAA AAA
Tested and Listed by
AAAAAAAAA
AAAAAAAAA
AAAAAAAAA OMNI-Test Laboratories, Inc.
Beaverton, Oregon
AAAAAAAAA
Report # 028-F-59b-5
ANSI Z21.88b-2003
AAAAAAAAA
• Built-In Direct Vent Fireplace
AAAAAAAAA
• Natural Gas or Propane
A

Summary of the content on the page No. 2

2 Introduction Overview This manual details the installation requirements for the 864 HH (Home Heater) fireplace. For operating and maintenance instructions, refer to the 864 HH Owner's Manual (part # 100-01181). Listing Details This appliance was listed by OMNI-Test Laboratories, Inc. to ANSI Z21.88 - report # 028- F-59b-5. The listing label is attached to the appliance near the gas control valve. A copy is shown to the right. IAS (ICBO) Approval This appliance was listed by OMNI-Test Laborat

Summary of the content on the page No. 3

Table of Contents 3 Introduction Installation (continued) Overview.................................................................2 Hearth Requirements ............................................... 32 Listing Details..........................................................2 Facing Requirements ............................................... 33 Drywall Installation ................................................33 Facing Overview ...................................................34 Safety P

Summary of the content on the page No. 4

4 Safety Precautions Safety Warnings: • Failure to follow all of the requirements may result in property damage, bodily injury, or even death. • This unit must be installed by a qualified installer to prevent the possibility of an explosion. • This appliance must be installed in accordance with all local codes, if any; if not, in U.S.A. follow ANSI Z223.1 and NFPA 54(88). • In Manufactured or Mobile Homes must confirm with: In USA, Manufactured Home Construction and Safety Standard, Title 24 CFR

Summary of the content on the page No. 5

Safety Precautions 5 Safety Warnings (continued): • Allow the heater to cool before carrying out any maintenance or cleaning. • Operate the heater according to the instructions included in this manual. • If the main burners do not start correctly turn the gas off at the gas control valve and call your dealer for service. • The pilot flame must contact the thermopile and thermocouple. If it does not, turn the gas control valve to "OFF" and call your dealer. • This unit is not for use with solid

Summary of the content on the page No. 6

6 Features and Specifications Installation Options • Residential or Mobile Home • Raised or Floor Placement • Straight or Corner Placement • Internal or External Chase • Flush or Recessed Face • Horizontal or Vertical Vent • Bedroom Approved Heating Specifications Natural Gas Propane Approximate Heating Capacity (in square feet)* 1,200 to 2,250 1,200 to 2,250 Maximum BTU Input Per Hour 40,000 39,000 Steady State Efficiency** (with blowers on) Up to 80 % Up to 81 % * Heating capacity will vary wi

Summary of the content on the page No. 7

Installation (for qualified installers only) 7 Packing List • Wall Switch with Wire (see page 20 for details) • Propane Conversion Kit • Firestop (sku 93006094 • Log Set (9 piece) • Grate Additional Items Required • FIREBACKS ARE REQUIRED – See page 47. (sku 98500662, 98500663, 98500664, or 98500665) • Direct Vent • Gas Line Equipment (shutoff valve, pipe, etc.) • Electrical Equipment (min. 14 gauge, grounded line) • Grill or Face Installation Overview • All requirements below must be met.

Summary of the content on the page No. 8

8 Installation (for qualified installers only) Massachusetts Requirements NOTE: The following requirements reference various Massachusetts and national codes not contained in this document. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termin

Summary of the content on the page No. 9

Installation (for qualified installers only) 9 Top Vent or Rear Vent Configuration This appliance is shipped in the rear vent configuration. To change to the top vent configuration, follow the directions below. NOTE: the vent configuration affects several aspects of installation (framing, maximum vent rise, maximum vent run). When reviewing the installation requirements make sure to pay attention to the type of configuration being used. Converting the Fireplace to Top Vent Remove the 4 screws

Summary of the content on the page No. 10

10 Installation (for qualified installers only) Converting the NOTE: Use a magnetic- Fireplace to Top Vent tipped nutdriver on these (continued) screws - take care to prevent the screws from falling into the fireplace. Remove the 12 screws securing the flue assembly. Rotate the flue assembly so the flue points upwards. Secure using the twelve screws removed earlier. DO NOT OVER- TIGHTEN THE SCREWS. Attach the intake cover plate with the screws removed earlier. Attach the cover pla

Summary of the content on the page No. 11

Installation (for qualified installers only) 11 Fireplace Placement Requirements • The fireplace requires a 1/2" clearance from the angled sides and back of the fireplace to the framing members. No material (insulation, framing, etc.) may be placed into this area. • Fireplace must be installed on a level surface capable of supporting the fireplace and vent • Fireplace must be placed directly on wood or non-combustible surface (not on linoleum or carpet) • This heater may be placed in a bedroom

Summary of the content on the page No. 12

12 Installation (for qualified installers only) Minimum Framing Dimensions - Rear Vent Configuration Included Firestop (required) HINT: place the fireplace so the center Part # 93006094 line is at least 5" from both vertical framing members at the rear (this allows the vent to pass through the framing without modfications) Vent Clearances (8" dia. Vent): 1" to the sides, 1" below, and 3" above the vent to combustibles. Center of Rear Vent AAAAA A AAAAAAAAAA A Minimum 49” Fireplace AA A

Summary of the content on the page No. 13

Installation (for qualified installers only) 13 Minimum Framing Dimensions - Top Vent Configuration Minimum 49” Fireplace Enclosure Height Route the electrical line to a position to the left rear of the fireplace. 38-1/2" 41-1/4" 20" The on/off switch/thermostat wire (if used) should be routed to a location near the right front of the fireplace. © Travis Industries 4080214 100-01182_003

Summary of the content on the page No. 14

14 Installation (for qualified installers only) Nailing Brackets There are four nailing brackets on the front of the fireplace. Follow the directions below to prepare the nailing brackets. Once in place, nail or screw the Make sure the fireplace is nailing brackets to the framing. square and plumb when placed in the framing. Measured corner-to- corner, the fireplace NOTE: Additional nailing should be square (approx. brackets are provided along 54-7/8” for each the base of the fi

Summary of the content on the page No. 15

Installation (for qualified installers only) 15 Corner Installations - Rear Vent Configuration A typical 45° installation uses the framing dimensions shown in the illustration below (NOTE: all clearances still apply). Travis Firestop Minimum 1/2" Clearance Minimum 1" Clearance (sku 93006094) AAAAAAAAAAAAA A AAAAAAAAAAAAA 7-1/2" Approximate (varies due to vent A A installation) A A A A A AAAAAAAAAAAAA A AAAAAAAAAAAAA NOTE: Most installations use: A AAAAAAAAAAAAA A AAAAAAAAAAAAA 6" Section for

Summary of the content on the page No. 16

16 Installation (for qualified installers only) Corner Installations - Top Vent Configuration A typical 45° installation uses the framing dimensions shown in the illustration below (NOTE: all clearances still apply). Minimum 1/2" Clearance AAAAAAAAAAAAA A A AA AAAAAAAAAAAA A AA A AA 15-1/2" A AA A AA A AAAAAAAAAAAAAAA A AAAAAAAAAAAAAAA A AAAAAAAAAAAAAAA A AAAAAAAAAAAAAAA 48" Min. A AAAAAAAAAAAAAAA A AAAAAAAAAAAAAAA A AAAAAAAAAAAAAAA A AAAAAAAAAAAAAAA AA AAAAAAAAAAAAAAA A AAAAAAAAAAAAAAA A AAAAA

Summary of the content on the page No. 17

Installation (for qualified installers only) 17 Gas Line Requirements MASSACHUSETTS INSTALLATIONS - WARNING: THIS PRODUCT MUST BE INSTALLED BY A LICENSED PLUMBER OR GAS FITTER WHEN INSTALLED WITHIN THE COMMONWEALTH OF MASSACHUSETTS. OTHER MASSACHUSETTS CODE REQUIREMENTS: • Flexible connector must not be longer than 36 inches. • Shutoff valve must be a “T” handle gas cock. • Only direct vent sealed combustion products are approved for bedrooms or bathrooms. • Fireplace dampers must be removed

Summary of the content on the page No. 18

18 Installation (for qualified installers only) Gas Line Location Left Side Gas Inlet (preferred) A 12" flex tube and shutoff valve is included A 2" high by 3" wide opening is located with the fireplace. The behind the gas inlet cover plate (it is 2" shutoff valve accepts a above the base of the fireplace). 1/2"MPT. The Gas Inlet is 3/8" FPT 6-3/4" You may remove this cover plate to install the gas line. The cover plate has a 7/8" diameter hole (covered with a push plug). By rotatin

Summary of the content on the page No. 19

Installation (for qualified installers only) 19 Electrical Connection (required) • The electrical line to the grounded receptacle inside the fireplace must be installed by a qualified installer and must meet all local codes. • Make sure the household breaker is shut off prior to working on any electrical lines. • The fireplace must be properly grounded in accordance with local codes (or ANSI/NFPA 70-1987) • The electrical line must be a min. 14 gauge, and supply 120 Volts at 60 Hz (2 Amps) Caut

Summary of the content on the page No. 20

20 Installation (for qualified installers only) Wall Switch or Thermostat Installation Wiring Diagram (Millivolt System) Do not connect 110-120 VAC to the gas control valve or wiring system of this fireplace. The switch must be installed by a qualified installer. The included wall switch may be installed following the directions below. An optional thermostat may also be installed. It is attached to the gas control valve in the same manner. Caution: Label all wires prior to disconnection when


Alternative user manuals
# User manual Category Download
1 Aquatic Exotic Flames Natural Gas User manual Fire Pit 0
2 Athena Technologies A88028 User manual Fire Pit 0
3 Avalon Stoves Gas Stove & Fireplace User manual Fire Pit 2
4 Baxi Potterton 339 User manual Fire Pit 1
5 Blue Rhino WAD808WDNC User manual Fire Pit 1
6 Breckwell TRADITION SERIES P23 P23FSL User manual Fire Pit 1
7 Breckwell TRADITION SERIES P23 P23FSA User manual Fire Pit 4
8 Breckwell TRADITION SERIES P23 P23I User manual Fire Pit 1
9 Brinkmann Ranch& Grill User manual Fire Pit 0
10 Brinkmann Gas FirePit User manual Fire Pit 0
11 Bryant GAS FIRED 394U User manual Fire Pit 0
12 Char-Broil FIREBOWL 6501121 User manual Fire Pit 1
13 Charnwood FIREPIT User manual Fire Pit 0
14 Coleman 5071 Series User manual Fire Pit 2
15 Coleman 5066 User manual Fire Pit 1