England's Stove Works 55TRPAH user manual

User manual for the device England's Stove Works 55TRPAH

Device: England's Stove Works 55TRPAH
Category: Gas Heater
Manufacturer: England's Stove Works
Size: 1.53 MB
Added : 10/6/2014
Number of pages: 46
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for England's Stove Works 55TRPAH. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with England's Stove Works 55TRPAH.

For your convenience

If looking through the England's Stove Works 55TRPAH user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual England's Stove Works 55TRPAH on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual England's Stove Works 55TRPAH to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
England's Stove Works 55TRPAH User manual - Online PDF
Advertisement
« Page 1 of 46 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual England's Stove Works 55TRPAH but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to England's Stove Works 55TRPAH. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

PELLET AUXILIARY HEATER 
 
 
 
INSTALLATION & OPERATION MANUAL 
25‐PAH/55‐SHPAH/55‐TRPAH      
 
                
 
 
Manufactured By: 
 
England’s Stove Works, Inc. 
 
PO Box 206 
Monroe, VA 24574 
 
     
   REV. 12/2011 
 
 
 
CAUTION
Please read this entire manual before installation and use of this pellet fuel‐
burning appliance.  Keep children, furniture, fixtures and all combustibles away 
from any heating appliance. 
SAFETY NOTICE
Failure to follow these instructions can result in proper

Summary of the content on the page No. 2

IMPORTANT: IF YOU HAVE A PROBLEM WITH THIS UNIT, DO  NOT RETURN IT TO THE DEALER.  CONTACT TECHNICAL  SUPPORT @ 1‐800‐245‐6489      Mobile Home Use:  This freestanding pellet unit is approved for mobile home or  doublewide installation with the outside combustion air hook‐ up.  See the “Installation” section of this manual for details  pertaining to mobile home installations.  Mobile home  installation must be in accordance with the Manufactured  Home and Safety Standard (HUD), CFR 3280, Part 24

Summary of the content on the page No. 3

TABLE OF CONTENTS    o Cleaning the Burnpot ..... 24  Introduction   Monthly   Introduction ................................. 4  o Important Notes............. 25  Specifications  o Exhaust Chamber ...... 25‐26   Heating Specifications .................. 5  o Venting Pipe ................... 26   Dimensions ................................... 5   Yearly   EPA Compliance ........................... 5  o Important Notes............. 27  o Exhaust Blower .............. 28  Installation  o Con

Summary of the content on the page No. 4

INTRODUCTION    Thank you for purchasing this fine product from England’s Stove Works!    England’s Stove Works was started, and is still owned by, a family that  believes strongly in a “Do It Yourself” spirit; that’s one reason you  found this product at your favorite “Do It Yourself” store.    We intentionally design and build our stoves so that any homeowner  can maintain their unit with basic tools, and we’re always more than  happy to show you how to do the job as easily and as inexpensivel

Summary of the content on the page No. 5

SPECIFICATIONS    Heating Specifications   Heat Output Range** ............................................ 11,000 BTU/hr – 25,000 BTU/hr   Approximate Pellet Burn Rate** ............................................... 1.6 lb/hr – 4.0 lb/hr   Maximum Burn Time** .............................................................................. 72 hours   Approximate Square Footage Heated*** ..................................... 800 ‐ 2000 sq. ft.   Hopper Capacity ..............................

Summary of the content on the page No. 6

INSTALLATION    Installation Overview  When choosing a location for your new stove, there are a multitude of  factors that should be taken into account before beginning the installation.    1. Traffic Patterns – To help prevent accidents, the stove should be placed  in a location where it is out of the way of normal travel through the  home.    2. Heat Flow – When deciding on a location for the stove, consider the way  heat moves throughout your home.  Install the stove where you need  the heat;

Summary of the content on the page No. 7

INSTALLATION    Clearances to Combustibles       D  B  C        E A    C      F          Unit to Side  Unit to Rear  Unit to  Unit Top to  Min. Ceiling  Min. Alcove  Max. Alcove  Wall  Wall  Corner  Ceiling  Height  Width  Depth    A  B  C  D  E  F  Not shown  12 in.  6 in.  6 in.  28.5 in.  60 in.  48.25 in.  24 in.  304.8 mm.  152.4 mm.  152.4 mm.  723.9 mm.  1524 mm.  1225.6 mm.  609.6 mm.  CAUTION  Keep children away.   Supervise children in the same room as this appliance.   Alert childr

Summary of the content on the page No. 8

INSTALLATION  Venting Introduction    This pellet stove operates on a negative draft system, which pulls combustion air  through the burn pot and pushes the exhaust air through the vent pipe and out of the building.   This unit must be installed in accordance with the following detailed descriptions of venting  techniques; not installing the stove in accordance with the details listed here can result in poor  stove performance, property damage, bodily injury or death.  England’s Stove Works is n

Summary of the content on the page No. 9

INSTALLATION    Additional Venting Information   Do not mix and match components from different pipe manufacturers when assembling  your venting system (i.e. Do NOT use venting pipe from one manufacturer and a thimble  from another).     We require a minimum vertical rise of 36 in. (3 ft.) of pipe to create natural draft in the  system, which helps evacuate smoke from the stove in the event of a power failure or  combustion blower failure.   Venting systems 15.0 ft. or shorter may be composed

Summary of the content on the page No. 10

INSTALLATION    Approved Venting Method 1: Through the Wall     Generally the simplest installation method,  venting through the wall using our AC‐3000  kit (or similar venting system) is also the  preferred venting method.  It minimizes  horizontal pipe, allows the stove to be  installed close to the wall and keeps the  clean‐out tee on the outside of the house,  for ease of cleaning.   When installing any venting system, Type L  or Type PL pipe must be used and all  clearances to combustible

Summary of the content on the page No. 11

INSTALLATION    Approved Venting Method 2: Through the Ceiling     Venting through the ceiling/roof may be the only  feasible venting option in some cases and is a factory  recommended installation.   When installing any venting system, Type L or Type  PL pipe must be used and all clearances to  combustibles listed by the pipe manufacturer must  be strictly adhered to.   Use the pipe manufacturer’s approved ceiling  support for passing through a combustible ceiling, as  well as the required f

Summary of the content on the page No. 12

INSTALLATION    Approved Venting Method 3: Existing Chimney System   Using an existing masonry or factory built chimney for  venting is the only other acceptable method for  venting this pellet unit.   Use Type L or Type PL venting pipe until entering the  existing chimney.  Use the appropriately sized adapter  when transitioning from the pellet vent pipe to the  masonry or factory built thimble and be certain that  the adapter is sealed tightly to both the pellet venting  system and the exist

Summary of the content on the page No. 13

INSTALLATION  Mobile Home Installation   The England’s Stove Works, Inc. outside air kit MUST be used for installation of this unit in a  mobile home.  Please see the “Outside Air” section on page 14 for more information  regarding outside air connections.   The outside air inlet must be kept clear of leaves, ice and other debris. Keeping the outside  air inlet free of restriction is crucial to preventing air starvation and smoke spillage.   The pellet stove MUST be secured to the floor of th

Summary of the content on the page No. 14

OUTSIDE AIR HOOK‐UP     The use of outside combustion air is mandatory on this pellet stove.   The outside air connection pipe protrudes from the lower rear center of the stove; use the  included outside air kit to attach your stove to outside combustion air.  Instructions and all  the parts needed to make the outside air connection to your pellet stove are included with  the outside air kit.   If it is not feasible to use the included outside air hookup kit in your stove installation, other 

Summary of the content on the page No. 15

FLOOR PROTECTION     This pellet stove requires a non‐combustible floor protector if the stove is to be installed on  a combustible floor.  If the floor the stove is to be installed on is already non‐combustible  (i.e. a concrete floor in a basement) and has an R value equal to or higher than .2, no floor  protection is needed (although a decorative floor protector can still be used for aesthetic  reasons).   Prefabricated floor protectors which are UL listed or equivalent can be purchased or 

Summary of the content on the page No. 16

DAILY OPERATION    Getting Started   Check to see that the hopper is clean and free from foreign materials.  Be sure to connect  this unit to a working outlet; we recommend using a surge protector to help protect the  electronic components from damage.   BEFORE your first fire, dry run your unit (no pellet fuel in the hopper) for twenty minutes;  pressing the “ON” button with the unit plugged in will initiate the dry run.    o Once the “ON” button is pressed, you should immediately hear the ex

Summary of the content on the page No. 17

 Shortly after pressing the “On” button, the letters “S U” will appear in the heat range and  blower speed windows of the control board.  This indicates the stove has entered the start‐ up sequence and is operating normally.   The fuel feed rate and combustion air during start‐up is determined by the control board, so  the stove may be started on any heat range.   After approximately fifteen minutes, the fire should be burning brightly and the “S U”  should disappear from the control board.  

Summary of the content on the page No. 18

CONTROL BOARD SETTINGS  The control board on this stove allows the user to adjust the heat output and convection  blower speed, turn the unit on and off, and test components for function (more on diagnostic  mode later).   The lower buttons on the control board (Low Fuel Feed, Low Burn Air, and Air on Temp) are  not meant to be adjusted during normal operation of the unit.  These buttons are factory  preset and can not be adjusted by the user.   To energize the unit and initiate a fire, press 

Summary of the content on the page No. 19

ERROR CODES  Error codes, or “E‐Codes,” are alphanumeric codes that will appear in the Heat Range and  Blower Speed windows of the Control Board if the unit experiences an abnormal condition.   Error codes are the control board’s way of telling the user that something isn’t operating  correctly within the stove, and that the unit should be carefully inspected before reigniting.  See  the “Trouble‐Shooting Guide,” page 30, for additional information on error codes.    E‐0   When this is displaye

Summary of the content on the page No. 20

 POWER FAILURE  If the power to the unit is interrupted for approximately three minutes or less, the unit will  resume operation when power is restored according to the following table:    Unit’s State Before Power Loss State When Power Returns  ON  Start‐Up  Start‐Up  Start‐Up  Shut‐Down  Shut‐Down  OFF  OFF     If the power is interrupted for more than (approximately) three minutes, the unit  will be “OFF” when power returns.   IMPORTANT – Do NOT open the hopper lid or the door to the unit d


Alternative user manuals
# User manual Category Download
1 England's Stove Works 55SHPAH User manual Gas Heater 0
2 England's Stove Works 25PAH User manual Gas Heater 0
3 Allied Air Enterprises 506271-01 User manual Gas Heater 0
4 Blue Rhino ALL WEATHER WOVEN HEATER GWU9850F / 35554 User manual Gas Heater 2
5 Breckwell ECONOMY P22FSL User manual Gas Heater 0
6 Breckwell ECONOMY P22FSA User manual Gas Heater 0
7 Breckwell ECONOMY P22I User manual Gas Heater 1
8 Briggs & Stratton 32K400 User manual Gas Heater 2
9 Bryan Boilers CLM240WP User manual Gas Heater 2
10 Bryan Boilers CLM180WP User manual Gas Heater 0
11 Bryan Boilers CLM270WP User manual Gas Heater 1
12 Bryan Boilers CLM300WP User manual Gas Heater 0
13 Bryan Boilers CLM90WP User manual Gas Heater 0
14 Cannon CANTFS-03-NG User manual Gas Heater 0
15 Cannon CANTFS-03-LP User manual Gas Heater 0