Empire Comfort Systems DVX36DP91(N,P)-1 user manual

User manual for the device Empire Comfort Systems DVX36DP91(N,P)-1

Device: Empire Comfort Systems DVX36DP91(N,P)-1
Category: Gas Heater
Manufacturer: Empire Comfort Systems
Size: 5.18 MB
Added : 9/23/2014
Number of pages: 72
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Empire Comfort Systems DVX36DP91(N,P)-1. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Empire Comfort Systems DVX36DP91(N,P)-1.

For your convenience

If looking through the Empire Comfort Systems DVX36DP91(N,P)-1 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Empire Comfort Systems DVX36DP91(N,P)-1 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Empire Comfort Systems DVX36DP91(N,P)-1 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Empire Comfort Systems DVX36DP91(N,P)-1 User manual - Online PDF
Advertisement
« Page 1 of 72 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Empire Comfort Systems DVX36DP91(N,P)-1 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Empire Comfort Systems DVX36DP91(N,P)-1. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION INSTRUCTIONS
AND
OWNER’S MANUAL
The Studio Series Direct Vent Zero
LUXURY DIRECT VENT
Clearance Gas Fireplace Heater
GAS FIREPLACE HEATER
MODEL SERIES
MILLIVOLT STANDING PILOT
DVX36DP31(N,P)-1
DVX42DP31(N,P)-1
INTERMITTENT PILOT
DVX36DP71(N,P)-1
DVX42DP71(N,P)-1
REMOTE RF
DVX36DP91(N,P)-1
DVX42DP91(N,P)-1
GAS-FIRED
Installer: Leave this manual with the appli-
ance.
UL FILE NO. MH30033
Consumer: Retain this manual for future refer-
ence.
WARNING: If the information in these instruc

Summary of the content on the page No. 2

TABLE OF CONTENTS Section Page Important Safety Information .....................................................................................................................................3 Safety Information for Users of LP Gas .....................................................................................................................

Summary of the content on the page No. 3

IMPORTANT SAFETY INFORMATION Before enclosing the vent pipe assembly, operate the appliance to ensure it is venting properly. DO NOT OPERATE THIS APPLIANCE WITHOUT GLASS FRONT PANEL INSTALLED • If this appliance is installed directly on carpeting, tile • Adequate accessibility clearances for servicing and proper or other combustible material other than wood flooring operation. the appliance shall be installed on a metal or wood panel • This appliance must not share or be connected to a flue e

Summary of the content on the page No. 4

SAFETY INFORMATION FOR USERS OF LP GAS Propane (LP-Gas) is a flammable gas which can cause fires by point with the members of your household. Someday when and explosions. In its natural state, propane is odorless and there may not be a minute to lose, everyone’s safety will depend colorless. You may not know all the following safety precau- on knowing exactly what to do. If, after reading the following tions which can protect both you and your family from an information, you feel you still ne

Summary of the content on the page No. 5

REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment installed 3. SIGNAGE. A metal or plastic identification plate shall be in every dwelling, building or structure used in whole or in part permanently mounted to the exterior of the building at a for residential purposes, including those owned or operated by the minimum height of eight (8) feet above grade directly in line Commonwealth and where the side wall exhaust vent termination with the exhaust vent

Summary of the content on the page No. 6

INTRODUCTION Instructions to Installer Any alteration of the original design, installed other than as 1. Installer must leave instruction manual with owner after shown in these instructions or use with a type of gas not shown on installation. the rating plate is the responsibility of the person and company 2. Installer must have owner fill out and mail warranty card supplied making the change. with the fireplace. Important 3. Installer should show owner how to start and operate the All corres

Summary of the content on the page No. 7

SPECIFICATIONS DVX36 NAT DVX36 LP DVX42 NAT DVX42 LP Input Btu/hr Maximum 35,000 30,000 37,500 35,000 Btu/hr Minimum 24,000 21,000 26,000 24,000 KWH (Maximum) 10.3 8.8 11.0 10.3 (Minimum) 7.2 6.2 7.6 7.2 Orifice #32 (P-211) 1.65 mm (P-250) #31 (P-209) #50 (P-245) Air Shutter Opening 1/4"(6.4 mm) FULL OPEN 1/4" (6.4 mm) FULL OPEN Height without standoff 34 3/4 (3.2 mm) 34 3/4" (3.2 mm) 34 3/4" (3.2 mm) 34 3/4" (3.2 mm) Width 39 3/8" (1,000 mm) 39 3/8" (1,000 mm) 43 3/8" (1,101

Summary of the content on the page No. 8

CLEARANCES Mantel Chart (Figure 3) Clearance to Combustibles Back 0" (0 mm) 12”(305mm) 10”(254mm) Side 0" (0 mm) Floor 0" (0 mm) MANTEL Top Stand-off 0" (0 mm) COMBUSTIBLETRIMAND 8” Top Framing Edge 6" (152 mm) MANTELSALLOWEDIN SHADEDAREA 6” 19” SEEMANTLECHARTFOR 41/2” MAXIMUMMANTLEDEPTH 33/4” 3” 183/4” 21/4” 2”x4”HEADER 11/2” 17” 16” 3/4” 15” STANDOFF 14” 6”(152mm)HEIGHT 13” 12” ABOVETOPOF 11” SEEMANTLECHART 10” FIREPLACE FORMINIMUMHEIGHT OFMANTLEABOVEUNIT TOPEDGEOFFIREPLACE FINISHEDWALL (COMBU

Summary of the content on the page No. 9

GAS SUPPLY Installing a New Main Gas Cock The gas pipeline can be brought in through the right or left side of the appliance. Consult the current National Fuel Gas Code, ANSI Each appliance should have its own manual gas cock. Z223.1 CAN/CGA-B149 (.1 or .2) installation code. A manual main gas cock should be located in the vicinity of the Recommended Gas Pipe Diameter unit. Where none exists, or where its size or location is not ad- Pipe Length Schedule 40 Pipe Tubing, Type L equate, contact

Summary of the content on the page No. 10

INSTALLATION Framing and Finishing VENT PIPE 1. Choose unit location. 2. Frame in fireplace with a header across the top. It is important to allow for finished face when setting the depth of the frame. 3. Attach fireplace to frame using adjustable nailing flange. Preset depth to suit facing material (adjustable to 3/8", 1/2" or 3/4" depths). Note: Fireplace must mount flush to facing material. If facing material requires more depth than 3/4" mark and drill two (2) 1/8" holes into fireplace

Summary of the content on the page No. 11

INSTALLATION (continued) DVX36 DVX42 "A" 40 7/8" 40 7/8" NAIL OR OTHER SUIT ABLE F ASTENER "B" 40 3/8" 43 3/8" Figure 10 "C" 19 7/8" 19 7/8" Framing (Figure 11) Figure 11 Fireplace framing can be built before or after the fireplace is set in place. Framing should be positioned to accommodate wall covering Attention: If a base is not used and the appliance is installed directly and fireplace facing material. The fireplace framing should be on tile or other combustible material other than wood

Summary of the content on the page No. 12

Flush Wall Installation FINISHED WALL Attention: Cold climate installation recommendation: When installing this unit against a non-insulated exterior 6”OFNON-COMBUSTIBLEMATERIAL wall, it is recommended that the outer walls be insulated to NON-COMBUSTIBLEMATERIAL conform to applicable insulation codes. (INSTALLATIONISOPTIONAL Vent Runs (Figures 14, 15, and 16) In planning the installation for the fireplace, it is necessary to install JOINTBETWEENFINISHED WALL ANDUNITSEALED certain components

Summary of the content on the page No. 13

INSTALLATION (continued) VERTICAL, 90° ELBOW TO CORNER INSTALLATION VERTICAL, 90° ELBOW TO HORIZONTAL OUT THE WALL HORIZONTAL OUT THE WALL WALLFIRESTOP/ “A” 90ºELBOW “A” THIMBLE PIPE LENGTH “B” 6”(152mm) MINIMUM “C” VENT CAP 9”(229mm) “D” MINIMUM VENTCAP WALLFIRESTOP/ THIMBLE “C” Dim. DVX36 DVX42 “B” 45 3/8" (1152 mm) 49 5/8" (1260 mm) A "A" "B" "C" 32 1/8" (816 mm) 35 1/8" (892 mm) B 6"(152 mm) 11 1/4"(286 mm) to 4 3/4"(121 mm) to 13 3/8" (34 mm) 15 1/2" (39 mm) C 12 3/4"(324 mm) 6 1/4"(159

Summary of the content on the page No. 14

VENTING FIREPLACE - TOP Venting Graph (Dimensions in Feet) To Use the Vent Graph (Figure 17) 1. Determine the height of the center of the horizontal vent pipe. Using this dimension on the Sidewall Vent Graph, TOP EXIT - VERTICAL AND HORIZONT AL TERMINA TION (DIMENSIONS IN FEET) locate the point it intersects with the slanted graph line. 2. From the point of this intersection, draw a vertical line to the bottom of the graph. 3. Select the indicated dimension, and position the unit in accordan

Summary of the content on the page No. 15

VENTING FIREPLACE - TOP (continued) Installation of Flue Heat Shield HOLESFOR42”MODELS 1. Remove flue insulation. TAB 2. Remove (2) screws on outside of inlet vent adapter. See Figure 18. 3. Lift top shield placing flue heat shield around flue. 4. Replace (2) screws on outside of inlet vent adapter. See Figure 19. 5. Bend tab at top front of flue heat shield if necessary to maintain air gap between flue pipe and flue heat shield. 6. Replace flue insulation. HOLESFOR36”MODELS Figure 18 NOTE:

Summary of the content on the page No. 16

VENTING FIREPLACE - TOP (continued) Below Grade Installation When it is not possible to meet the required vent terminal clearances of 12" (305mm) above grade level, a snorkel kit is recommended. It allows installation depth down to 7" (178 mm) below grade level. The 7" (178 mm) is measured from the center of the horizontal vent pipe as it penetrates through the wall. Ensure the sidewall venting clearances are observed. If venting system is installed below ground, we recommend a window well

Summary of the content on the page No. 17

10” (254mm) VENTCAP C 12” B (305mm) V H SEECHARTFOR PERMISSIBLE “H”AND“V” C DIMENSIONS 9”(229mm)minimum B TOSIDEWALL A CENTEROFELBOW STRAIGHTOUT (MINIMUM) Figure 24 3’ (914mm) Figure 23 MINIMUM HOLE LOCATION DIMENSIONS FOR THROUGH THE WALL HORIZONTAL INSTALLATIONS WITH 90 DEGREE ELBOW OFF TOP OF FIREPLACE FIREPLACE HARD ELBOW DIMENSIONS SERIES "A" "B" "C" DVX36FP 43-1/2" 5" 7" (1105 mm) (127 mm) (178 mm) MAXIMUMHORIZONTAL RUNWITHNOVERTICAL DVX42FP 43-1/2" 5" 7" RISEAND90°ELBOW (1105 mm) (1

Summary of the content on the page No. 18

EXAMPLES - TOP VENT RUN Example H2 3ft, H3 1ft = 4ft (90° + 90° + 90°) = 6ft V1 = 21ft H = 10ft V = 21ft Figure 27 Figure 26 Example H1 = 2ft V1 = 20ft H = 2ft V = 20ft Figure 28 Page 18 25613-0-0309

Summary of the content on the page No. 19

DVVK-4FV DIRECT VENT TERMINATION KIT Installation Instructions This termination kit can only be used with Empire Comfort Systems direct vent fireplaces listed for use with DVVK-4FV Vertical Flex Vent Kit. Please review the instructions packaged with your fireplace and verify the fireplace model number. Check that this flex vent system is listed for use with your fireplace model prior to starting the installation. This vent kit may be installed as an OEM installation in a manufactured home (US

Summary of the content on the page No. 20

DVVK-4FV DIRECT VENT TERMINATION KIT (cont.) PRE-INSTALLATION INFORMATION: Items Required For Installation: Tools Building Supplies Phillips Screwdriver Framing Materials Hammer Wall Finishing Materials Saw and/or saber saw Caulking Material (Noncombustible) Level Support Strap supplies Measuring Tape Electric Drill and Bits Pliers Square Tin Snips Before You Start: Plan your installation. Read these instructions and the fireplace installation manual before installing unit and vent system. Set u


Alternative user manuals
# User manual Category Download
1 Empire Comfort Systems DVX36DP31(N,P)-1 User manual Gas Heater 1
2 Empire Comfort Systems DVX36DP71(N,P)-1 User manual Gas Heater 4
3 Empire Comfort Systems DVX42DP91(N,P)-1 User manual Gas Heater 0
4 Empire Comfort Systems DVX42DP71(N,P)-1 User manual Gas Heater 0
5 Empire Comfort Systems DVX42DP31(N,P)-1 User manual Gas Heater 0
6 Empire Comfort Systems LS-18C2-1 User manual Gas Heater 0
7 Empire Comfort Systems LS-18C2S-1 User manual Gas Heater 0
8 Empire Comfort Systems LS-18FAC-1 User manual Gas Heater 0
9 Empire Comfort Systems LS-18FAO-1 User manual Gas Heater 0
10 Empire Comfort Systems 30 User manual Gas Heater 0
11 Empire Comfort Systems LS-18FAS-1 User manual Gas Heater 0
12 Empire Comfort Systems LS-18RSS-1 User manual Gas Heater 0
13 Empire Comfort Systems LS-16C-2 User manual Gas Heater 0
14 Empire Comfort Systems LS-24FAO-1 User manual Gas Heater 0
15 Empire Comfort Systems LS-24FAS-1 User manual Gas Heater 0
16 Allied Air Enterprises 506271-01 User manual Gas Heater 0
17 Blue Rhino ALL WEATHER WOVEN HEATER GWU9850F / 35554 User manual Gas Heater 2
18 Breckwell ECONOMY P22FSL User manual Gas Heater 0
19 Breckwell ECONOMY P22FSA User manual Gas Heater 0
20 Breckwell ECONOMY P22I User manual Gas Heater 1