Desa BDV34N(A) user manual

User manual for the device Desa BDV34N(A)

Device: Desa BDV34N(A)
Category: Outdoor Fireplace
Manufacturer: Desa
Size: 1.19 MB
Added : 3/17/2013
Number of pages: 38
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Desa BDV34N(A). Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Desa BDV34N(A).

For your convenience

If looking through the Desa BDV34N(A) user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Desa BDV34N(A) on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Desa BDV34N(A) to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Desa BDV34N(A) User manual - Online PDF
Advertisement
« Page 1 of 38 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Desa BDV34N(A) but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Desa BDV34N(A). If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
DIRECT-VENT FIREPLACE
OWNER’S OPERATION AND INSTALLATION MANUAL
®
BDV34N(A) AND BDV34P(A)
WARNING: Improper instal-
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result causing
lation, adjustment, altera-
property damage, personal injury, or loss of life.
tion, service, or mainte-
nance can cause injury or
property damage. Refer to
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors
this manual for correct in-
and liquids in the

Summary of the content on the page No. 2

® DIRECT-VENT FIREPLACE (NATURAL/PROPANE) 1. This appliance is only for use with the 10. Have venting system inspected annu- SAFETY type of gas indicated on the rating plate. ally by a qualified service person. If INFORMATION This appliance is not convertible for use needed, have venting system cleaned with other gases unless a certified kit or repaired. See Cleaning and Mainte- is used. nance, page 26. WARNINGS 2. For propane fireplace, do not place pro- 11. Keep the area around your fireplace

Summary of the content on the page No. 3

OWNER’S MANUAL PRODUCT LOCAL CODES Install and use fireplace with care. Follow all IDENTIFICATION local codes. In the absence to local codes, use the current National Fuel Gas Code ANS Z223.1, also known as NFPA 54* (USA) Top Louver Vent Opening or the current CAN/CGA-B149[.1 or .2] Panel Installation Codes (Canada). Stand-off Nailing Flange *Available from: American National Standards Institute, Inc. Glass Door Assembly 1430 Broadway New York, NY 10018 National Fire Protection Associat

Summary of the content on the page No. 4

® DIRECT-VENT FIREPLACE (NATURAL/PROPANE) CLEARANCES PRE-INSTALLATION Must maintain a minimum Minimum clearances to combustibles for 1" clearance to combustibles PREPARATION the fireplace are as follows: LOCATION AND SPACE Back, and sides 0"/mm REQUIREMENTS Perpendicular walls 6" (152mm) Floor 0"/mm Determine the safest and most efficient loca- Ceiling to louver opening 42" (1067mm) tion for your Vanguard direct-vent fireplace. Front 36" (914mm) Make sure that rafters and wall studs are not To

Summary of the content on the page No. 5

OWNER’S MANUAL PRE-INSTALLATION GENERAL VENTING PREPARATION These models are approved for use with Continued 5 Simpson Dura-Vent 6 /8" direct-vent pipe components and terminations as well as both flex and rigid Vanguard vent components. Your fireplace is approved to be vented either 13" 1 through the side wall, or vertically using the 9 /4" 41" following guidelines: 29" • Only use Vanguard or Simpson Dura- Vent GS venting components or kits spe- cifically approved for this fireplace. • Minimum c

Summary of the content on the page No. 6

V G G V A E D V B L ® DIRECT-VENT FIREPLACE (NATURAL/PROPANE) GENERAL VENTING Continued N N H C I B Fixed V V Fixed Closed Openable Closed Openable B F V J G V X B B M A V K X TERMINATION CAP G GAS METER RESTRICTED AREA V X AIR SUPPLY INLET (TERMINATION PROHIBITED) A = clearance above grade, veranda, porch, deck, or balcony I = clearance to service regulator vent outlet [*72 inches (1829mm) [*12 inches (305mm) minimum] minimum] B = clearance to window or door that may be opened J = clearance to

Summary of the content on the page No. 7

OWNER’S MANUAL • Installation of any component part not You may use one or two 90° elbows in this VENTING manufactured or approved by DESA vent configuration. See Vertical Termination INSTALLATION International Configurations on pages 13 through 15. • Installation other than as instructed by Note: You may use two 45° elbows in place WARNING: Read all instruc- these instructions of a 90° elbow. You must follow rise to run tions completely and thoroughly ratios when using 45° elbows. before attem

Summary of the content on the page No. 8

® DIRECT-VENT FIREPLACE (NATURAL/PROPANE) Snorkel VENTING INSTALLATION Continued INSTALLATION FOR HORIZONTAL TERMINATION 1. Determine the route your horizontal venting will take. Note: The location of the horizontal vent termination on the exterior wall must meet all local and 12" Minimum national building codes and must not To Ground Level be easily blocked or obstructed. WARNING: Do not recess vent terminal into a wall or siding. Snorkel terminations are available for terminations requi

Summary of the content on the page No. 9

OWNER’S MANUAL 4. Apply a bead of non-hardening mastic 6. Carefully move the fireplace with vent VENTING around the outside edge of the vent cap. assembly attached toward the wall and INSTALLATION Position the vent cap in the center of insert the vent pipe into the horizontal 1 the 7 /2" or 10" hole on the exterior termination. The pipe overlap should Continued 1 wall with the arrow on the vent cap be a minimum of 1 /4". Apply silicone 3. Attach vent pipe assembly to the fire- pointing up. Insur

Summary of the content on the page No. 10

UP UP UP ® DIRECT-VENT FIREPLACE (NATURAL/PROPANE) VENTING INSTALLATION Continued Horizontal Venting Vertical (V) Horizontal (H) Horizontal Termination 44" min. 29" max. Configurations (30° and 90° only, no vertical pipe) Figures 16 through 20 show different con- 55" min. 41" max. figurations for venting with horizontal ter- (30° elbow, 1' vertical pipe, 90° elbow) mination. Each figure includes a chart with vertical minimum/maximum and horizon- 67" min. 60" max. tal maximum dimensions which mus

Summary of the content on the page No. 11

UP OWNER’S MANUAL VENTING INSTALLATION Continued Venting with Two 90° Elbows Vertical (V) Horizontal (H ) Horizontal (H ) + 1 1 Horizontal (H ) 2 5' min. 2' max. 6' max. 6' min. 4' max. 12' max. 7' min. 6' max. 18' max. 8' min. 8' min. 20' max. 20' max. 8' max. 20' max. Figure 19 - Horizontal Termination Configuration for Rigid Venting Using Two 90° Elbows Venting with Two 90° Elbows Vertical (V) Horizontal (H ) + 1 Horizontal (H ) 2 5' min. 6' max. 6' min. 12' max. 7' min. 18' max. 8' min. 20'

Summary of the content on the page No. 12

® DIRECT-VENT FIREPLACE (NATURAL/PROPANE) 4. Connect a section of pipe and extend Flat Ceiling Installation VENTING up through the hole. 1. Cut a 10" square hole in the ceiling us- INSTALLATION Note: If an offset is needed to avoid ing the locating hole as a center point. Continued obstructions, you must support the vent The opening should be framed to pipe every 3 feet. Use wall straps for 10"x10" (254mm x 254mm) inside di- INSTALLATION FOR this purpose (see Figure 21). Whenever mensions, as sh

Summary of the content on the page No. 13

OWNER’S MANUAL Vertical Termination Configurations VENTING Figures 25 through 28 show four different configurations for vertical termination. All INSTALLATION connections must be sealed with high temperature silicone sealant as specified in the second Continued warning statement on page 7. 3. Lower the support box through the hole Venting with Two 90° Elbows in the roof until the bottom of the box extends at least 2" below the ceiling Vertical (V) Horizontal (H ) + 1 (see Figure 23). Align

Summary of the content on the page No. 14

® DIRECT-VENT FIREPLACE (NATURAL/PROPANE) VENTING INSTALLATION Continued Note: Install restrictor into 4" collar of stove as shown. RVF Kit Shown Vertical Venting Venting with Two 90° Elbows V = 30' max. Vertical (V ) Horizontal (H) 1 Figure 28 - Vertical Rigid Venting 5' min. 6' max. Configuration With No Horizontal Run 6' min. 12' max. 7' min. 18' max. 8' min. 20' max. Note: Vertical (V ) + 1 Vertical (V ) = 20' max. 2 Figure 27 - Vertical Rigid Venting Configuration Using Two 90° Elbows 1054

Summary of the content on the page No. 15

OWNER’S MANUAL Vanguard Rigid Venting (Cont.) Vanguard Flexible Venting (Cont.) VENTING Number Description Number Description INSTALLATION SVK Snorkel Rigid Vent Kit FGFVK Flex Ground Floor Vent Kit Continued Includes: 7" x 30° Elbow, 7" x 4' Includes: Flex Adapter, 7" x 4' Flex- Galvanized Pipe, 7" x 90° Elbow, 7" ible Pipe, 4" x 4' Flexible Pipe, Wall HIGH ALTITUDE Adjustable Galvanized Pipe (7-12"), Thimble, Horizontal Termination, INSTALLATION Wall Thimble, 36" Snorkel Termi- (4) Spacer Spri

Summary of the content on the page No. 16

® DIRECT-VENT FIREPLACE (NATURAL/PROPANE) Installing GA3700/DA3610T CHECK GAS TYPE FIREPLACE Blowers Use proper gas type for the fireplace unit INSTALLATION IMPORTANT: For clarity, gas valve assem- you are installing. If you have conflicting bly and grate/burner assembly are not shown gas types, do not install fireplace. See dealer NOTICE: This heater is intended in Figures 30 through 33, page 17. They will, where you purchased the fireplace for proper for use as supplemental heat. Use however,

Summary of the content on the page No. 17

OWNER’S MANUAL 9. Check to make sure that the power cord FIREPLACE WARNING: Failure to position is completely clear of the blower wheel the parts in accordance with sup- INSTALLATION and that there are no other foreign ob- plied diagrams or failure to use jects in blower wheel. Turn blower on Continued only parts specifically approved and check for operation. Turn blower 8. Plug in blower power cord. with this heater may result in dam- off by rotating knob fully counterclock- a. If your firepla

Summary of the content on the page No. 18

® DIRECT-VENT FIREPLACE (NATURAL/PROPANE) Check your building codes for any special FIREPLACE CAUTION: Use only new, requirements for locating manual shutoff black iron or steel pipe. Inter- INSTALLATION valve to fireplaces. nally-tinned copper tubing may Continued Apply pipe joint sealant lightly to male be used in certain areas. Check threads. This will prevent excess sealant your local codes. Use pipe of 1/2" INSTALLING GAS PIPING TO from going into pipe. Excess sealant in pipe diameter or g

Summary of the content on the page No. 19

OWNER’S MANUAL 3. Pressurize supply piping system by ei- CHECKING GAS FIREPLACE ther opening propane supply tank valve CONNECTIONS INSTALLATION for propane gas fireplace or opening main gas valve located on or near gas Continued WARNING: Test all gas pip- meter for natural gas fireplace, or using ing and connections for leaks CONNECTING FIREPLACE compressed air. after installing or servicing. Cor- TO GAS SUPPLY 4. Check all joints of gas supply piping rect all leaks at once. system. Apply comme

Summary of the content on the page No. 20

® DIRECT-VENT FIREPLACE (NATURAL/PROPANE) 2. Route the 25 ft. wire through openings INSTALLING OPTIONAL FIREPLACE provided on the sides of the fireplace WALL MOUNT SWITCH INSTALLATION to a convenient location to mount your GWMS2 switch. Continued 1. Connect one terminal of 25 ft. wire for 3. Connect one bare wire end to each of the wall switch to the TPTH terminal Test Pressures Equal To or Less Than the terminals of the GWMS2 Wall on the valve. Connect remaining wire 1/2 PSIG (3.5 kPa) Switch.


Alternative user manuals
# User manual Category Download
1 Desa BDV34NA User manual Indoor Fireplace 0
2 Desa (V)3612ST User manual Outdoor Fireplace 0
3 Desa (V)CD36RP User manual Outdoor Fireplace 1
4 Desa (V)CD36RNE User manual Outdoor Fireplace 0
5 Desa (V)CD36RPE User manual Outdoor Fireplace 0
6 Desa (V) CD36R(N User manual Outdoor Fireplace 0
7 Desa (V)CD36TN User manual Outdoor Fireplace 0
8 Desa (V) CD36T(N User manual Outdoor Fireplace 0
9 Desa (V)CD36TNE User manual Outdoor Fireplace 0
10 Desa (V)CD36TP User manual Outdoor Fireplace 0
11 Desa (V)JM36 User manual Outdoor Fireplace 0
12 Desa (V)K36EN User manual Outdoor Fireplace 0
13 Desa (V)CD36TPE User manual Outdoor Fireplace 0
14 Desa (V)JM50 User manual Outdoor Fireplace 0
15 Desa (V)JM42 User manual Outdoor Fireplace 1
16 Blue Rhino FIREPLACE WAF513C User manual Outdoor Fireplace 0
17 Blue Rhino 255635 User manual Outdoor Fireplace 1
18 Blue Rhino GAD860SP User manual Outdoor Fireplace 3
19 Blue Rhino 252207 User manual Outdoor Fireplace 1
20 Blue Rhino 251828 User manual Outdoor Fireplace 1