Desa VP5D user manual

User manual for the device Desa VP5D

Device: Desa VP5D
Category: Gas Heater
Manufacturer: Desa
Size: 0.35 MB
Added : 1/4/2014
Number of pages: 20
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Desa VP5D. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Desa VP5D.

For your convenience

If looking through the Desa VP5D user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Desa VP5D on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Desa VP5D to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Desa VP5D User manual - Online PDF
Advertisement
« Page 1 of 20 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Desa VP5D but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Desa VP5D. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
INFRARED VENT-FREE PROPANE/LP GAS HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
VP5D
and
VP10A
WARNING: Improper installation,
WARNING: If the information in this manual is
adjustment, alteration, service,
not followed exactly, a fire or explosion may
or maintenance can cause injury
result causing property damage, personal in-
or property damage. Refer to this
jury, or loss of life.
manual for correct installation
— Do not store or use gasoline or other flammable
and operational procedures.

Summary of the content on the page No. 2

® VP5D AND VP10A PROPANE/LP GAS HEATERS 4. Heater model VP10A shall not be in- SAFETY Due to high temperatures, the stalled in a bathroom. appliance should be located out INFORMATION 5. Always run heater with control knob of traffic and away from furniture at LOW or HIGH locked positions and draperies. WARNINGS (VP10A) or ON position (VP5D). Never set control knob between locked Do not place clothing or other IMPORTANT: Read this owner’s positions. Poor combustion may result. flammable materia

Summary of the content on the page No. 3

OWNER’S MANUAL PRODUCT PRODUCT IDENTIFICATION FEATURES Piezo Ignitor Button SAFETY PILOT Control Knob This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air. PIEZO IGNITION SYSTEM Grill Guard This heater has a piezo ignitor. This system requires no matches, batteries, or other Burners sources to light heater. Heater Cabinet Front Panel

Summary of the content on the page No. 4

® VP5D AND VP10A PROPANE/LP GAS HEATERS Confined and Unconfined Space PROVIDING ADEQUATE AIR FOR VENTILATION The National Fuel Gas Code ANS Z223.1 COMBUSTION AND defines a confined space as a space whose The following are excerpts from National VENTILATION volume is less than 50 cubic feet per 1,000 Fuel Gas Code. NFPA 54/ANS Z223.1, Sec- Btu per hour (4.8 m3 per kw) of the aggre- tion 5.3, Air for Combustion and Ventilation. gate input rating of all appliances installed WARNING: This heater s

Summary of the content on the page No. 5

OWNER’S MANUAL AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width x Height = _________________cu. f

Summary of the content on the page No. 6

® VP5D AND VP10A PROPANE/LP GAS HEATERS AIR FOR COMBUSTION AND 12" VENTILATION Continued VENTILATION AIR Ventilation Grills Into Adjoining Room, Ventilation Air From Inside Ventilation Option 2 Grills Building Or into Adjoining Remove This fresh air would come from an adjoining Room, Door into Option 1 Adjoining unconfined space. When ventilating to an Room, adjoining unconfined space, you must pro- Option 3 vide two permanent openings: one within 12" of the ceiling and one within 12" of

Summary of the content on the page No. 7

OWNER’S MANUAL LOCATING HEATER CEILING INSTALLATION This heater is designed to be mounted on a NOTICE: This heater is intended wall. 36" for use as supplemental heat. Use Minimum this heater along with your pri- 8" WARNING: Maintain the mini- Minimum mary heating system. Do not in- From mum clearances shown in Figure Sides Of stall this heater as your primary 4. If you can, provide greater clear- Heater heat source. If you have a central ances from floor, ceiling, and join- heating system, you

Summary of the content on the page No. 8

® VP5D AND VP10A PROPANE/LP GAS HEATERS Thin or Thick Installing Bottom Mounting INSTALLATION Wall (thick Screw Continued wall shown) 1. Locate bottom mounting hole. This Installing Two Mounting Screws 1/16" hole is near bottom on back panel of Space heater (see Figure 11). Note: Wall anchors and mounting screws are in hardware package. The hardware pack- 2. Mark screw location on wall. Solid age is provided with heater. 3. Remove heater from wall. Wall Attaching To Wall Stud Method 4. If insta

Summary of the content on the page No. 9

OWNER’S MANUAL Apply pipe joint sealant lightly to male INSTALLATION CAUTION: Use only new, threads. This will prevent excess sealant Continued black iron or steel pipe. Inter- from going into pipe. Excess sealant in pipe nally-tinned copper tubing may could result in clogged heater valves. CONNECTING TO GAS be used in certain areas. Check SUPPLY your local codes. Use pipe 3/8" CAUTION: Use pipe joint seal- diameter or greater to allow ant that is resistant to liquid pe- proper gas volume to h

Summary of the content on the page No. 10

® VP5D AND VP10A PROPANE/LP GAS HEATERS 2. Pressurize supply piping system by ei- INSTALLATION OPERATING ther using compressed air or opening Continued propane/LP supply tank valve. HEATER CHECKING GAS 3. Check all joints from propane/LP sup- FOR YOUR SAFETY ply tank to equipment shutoff valve (see CONNECTIONS READ BEFORE Figure 15). Apply mixture of liquid LIGHTING soap and water to gas joints. Bubbles WARNING: Test all gas pip- forming show a leak. ing and connections for leaks WARNING: If

Summary of the content on the page No. 11

OWNER’S MANUAL Control Knob Control VP10A Ignitor Button OPERATING Knob Burners OFF OFF PILOT HEATER PILOT Continued LOW LIGHTING IGNITOR LOW INSTRUCTIONS OFF HIGH PILOT 1. STOP! Read the safety information, Figure 16 - Control Knob In The OFF page 10, column 3. Position (Model VP10A Shown) 2. Make sure equipment shutoff valve HIGH Ignitor Electrode is fully open. OFF Pilot Burner 3. Turn control knob clockwise Thermocouple to the OFF position. 4. Wait five (5) minutes to clear out any gas. The

Summary of the content on the page No. 12

® VP5D AND VP10A PROPANE/LP GAS HEATERS CLEANING BURNER INSPECTING PILOT AIR INLET HOLE BURNER We recommend that you clean the unit every Check pilot flame pattern and burner flame 2,500 hours of operation or every three months. pattern often. We also recommend that you keep the burner tube and pilot assembly clean and free of dust PILOT FLAME PATTERN and dirt. To clean these parts we recommend Figure 19 shows a correct pilot flame pat- using compressed air no greater than 30 PSI. tern. Figure

Summary of the content on the page No. 13

OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off heater CAUTION: Never use a wire, Note: For additional help, visit DESA and let cool before servicing. Only needle, or similar object to clean a qualified service person should International’s technical service web site ODS/pilot. This can damage ODS/ service and repair heater. at www.desatech.com. pilot unit. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When ignitor button is pressed a

Summary of the content on the page No. 14

® VP5D AND VP10A PROPANE/LP GAS HEATERS TROUBLESHOOTING Continued POSSIBLE CAUSE OBSERVED PROBLEM REMEDY 1. Burner orifice(s) is clogged Burner(s) does not light after ODS/pilot is lit 1. Clean burner orifice(s) (see Cleaning and Maintenance, page 12) or replace burner orifice(s) 2. Burner orifice(s) diameter is too small 2. Replace burner orifice(s) 3. Inlet gas pressure is too low 3. Contact local propane/LP gas company 1. Manifold pressure is too low Delayed ignition of burner(s) 1. Contact

Summary of the content on the page No. 15

OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette

Summary of the content on the page No. 16

® VP5D AND VP10A PROPANE/LP GAS HEATERS 21 ILLUSTRATED 18 PARTS 17 14 20 BREAKDOWN VP5D 22 8 7-1 4 7-2 7 16 6 15 19 22 13 5 6 11 ODS/PILOT 3 10 9 12 2 1 This list contains replaceable parts used in your heater. When ordering parts, follow the instructions PARTS LIST listed under Replacement Parts on page 18 of this manual. KEY PART KEY PART NO. NUMBER DESCRIPTION QTY. NO. NUMBER DESCRIPTION QTY. 1 098304-01 Screw, #10 x 3/8" 2 13 100829-01 Control Valve 1 2 099467-03 Front Panel Assembly 1 14 0

Summary of the content on the page No. 17

B A OWNER’S MANUAL 22 19 ILLUSTRATED 15 18 PARTS 21 BREAKDOWN 23 VP10A 8 4 7-1 7 7-2 17 6 16 20 23 14 5 6 11 3 ODS/PILOT 10 9 13 2 9 12 1 This list contains replaceable parts used in your heater. When ordering parts, follow the instructions PARTS LIST listed under Replacement Parts on page 18 of this manual. KEY PART KEY PART NO. NUMBER DESCRIPTION QTY. NO. NUMBER DESCRIPTION QTY. 1 098304-01 Screw, #10 x 3/8" 2 14 100432-01 Control Valve 1 15 099468-17 Cabinet Assembly 1 2 099467-03 Front Panel

Summary of the content on the page No. 18

® VP5D AND VP10A PROPANE/LP GAS HEATERS SPECIFICATIONS REPLACEMENT VP10A VP5D PARTS Btu (Variable) 5,500/10,000 5,500 Note: Use only original replacement parts. Type Gas Propane/LP Only Propane/LP Only This will protect your warranty coverage for Ignition Piezo Piezo parts replaced under warranty. Pressure Regulator Setting 8" W.C. 8" W.C. PARTS UNDER WARRANTY Inlet Gas Pressure (inches of water) Contact authorized dealer from whom you Maximum 14" 14" purchased this product. If they are unable

Summary of the content on the page No. 19

OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________

Summary of the content on the page No. 20

WARRANTY INFORMATION KEEP THIS WARRANTY Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. LIMITED WARRANTY VANGUARD VENT-FREE RESIDENTIAL GAS HEATERS DESA International warrants this product to be free from defects in materials and components for fou


Alternative user manuals
# User manual Category Download
1 Desa 125-R User manual Gas Heater 0
2 Desa BG30P User manual Gas Heater 0
3 Desa 30-80 User manual Gas Heater 0
4 Desa 75-200 User manual Gas Heater 0
5 Desa BG30N User manual Gas Heater 0
6 Desa BG30NT User manual Gas Heater 0
7 Desa BCLP375 User manual Gas Heater 0
8 Desa BG30PT User manual Gas Heater 0
9 Desa 125-RN User manual Gas Heater 0
10 Desa BLP35E User manual Gas Heater 0
11 Desa BVDR18 User manual Gas Heater 1
12 Desa BVDR24 User manual Gas Heater 0
13 Desa BVDR30 User manual Gas Heater 0
14 Desa BVSR18 User manual Gas Heater 0
15 Desa CB36N User manual Gas Heater 0
16 Allied Air Enterprises 506271-01 User manual Gas Heater 0
17 Blue Rhino ALL WEATHER WOVEN HEATER GWU9850F / 35554 User manual Gas Heater 2
18 Breckwell ECONOMY P22FSL User manual Gas Heater 0
19 Breckwell ECONOMY P22FSA User manual Gas Heater 0
20 Breckwell ECONOMY P22I User manual Gas Heater 1