Desa R user manual

User manual for the device Desa R

Device: Desa R
Category: Gas Heater
Manufacturer: Desa
Size: 4.52 MB
Added : 8/2/2013
Number of pages: 40
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Desa R. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Desa R.

For your convenience

If looking through the Desa R user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Desa R on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Desa R to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Desa R User manual - Online PDF
Advertisement
« Page 1 of 40 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Desa R but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Desa R. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

UNVENTED (VENT-FREE) GAS LOG HEATER
TM
OWNER’S OPERATION AND INSTALLATION MANUAL
For more information, visit www.desatech.com For more information, visit www.desatech.com
("A" Models) 18", 24", and 30"
Remote-Ready
(“C” Models) 18", 24", and 30"
Variable Manually-Controlled
(“B” Models) 18", 24", and 30"
LO
PILOT
Thermostatically-Controlled
OFF
HI
Remote-Ready and Variable Manually-Controlled Models
Also Design-Certified As Vented Decorative Appliances
WARNING: Improper installation, adjust-
WAR

Summary of the content on the page No. 2

TABLE OF CONTENTS 2 SAFETY INFORMATION TABLE OF CONTENTS SAFETY INFORMATION ............................................................ 2 TROUBLESHOOTING .............................................................. 24 OPTIONAL POSITIONING OF PRODUCT IDENTIFICATION ..................................................... 3 OPTIONAL REMOTE CONTROL ACCESSORIES .................... 4 THERMOSTAT SENSING BULB ........................................... 27 LOCAL CODES ................................

Summary of the content on the page No. 3

WARMER TEMP COOLER AUTO ON OFF SAFETY INFORMATION 3 PRODUCT IDENTIFICATION 3 SAFETY INFORMATION Continued 1. This appliance is only for use with the type of gas indicated on 14. Turn heater off and let cool before servicing, installing, or re- the rating plate. This appliance is not convertible for use with pairing. Make sure the selector switch is in the OFF position other gases. (Remote-Ready Models Only). Only a qualified service per- son should install, service, or repair heater. 2. Do not p

Summary of the content on the page No. 4

OPTIONAL REMOTE CONTROL ACCESSORIES 4 LOCAL CODES UNPACKING PRODUCT FEATURES AIR FOR COMBUSTION AND VENTILATION Providing Adequate Ventilation OPTIONAL REMOTE CONTROL ACCESSORIES There are four optional remote controls that can be purchased SAFETY DEVICE separately for Remote-Ready Models Only: This heater has a pilot with an Oxygen Depletion Sensing (ODS) • wall switch • hand-held ON/OFF remote safety shutoff system. The ODS/pilot is a required feature for vent- • wall thermostat • hand-held th

Summary of the content on the page No. 5

AIR FOR COMBUSTION AND VENTILATION 5 Providing Adequate Ventilation (Cont.) 5 Determining Fresh-Air Flow for Heater Location AIR FOR COMBUSTION AND VENTILATION Continued Unusually tight construction is defined as construction 2. Multiply the space volume by 20 to determine the maximum Btu/Hr where: the space can support. a. walls and ceilings exposed to the outside atmosphere __________ (volume of space) x 20 = (Maximum Btu/Hr the space have a continuous water vapor retarder with a rating can su

Summary of the content on the page No. 6

AIR FOR COMBUSTION AND VENTILATION Ventilation Air 6 AIR FOR COMBUSTION AND VENTILATION Continued VENTILATION AIR 12" Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must Ventilation provide two permanent openings: one within 12" of the ceiling and Ventilation Grills Grills Into Adjoining Room, one within 12" of the floor on the wall connecting the two spaces Into Adjoining Or Option 2 (s

Summary of the content on the page No. 7

INSTALLATION 7 Check Gas Type 7 Installation and Clearances for Vent-Free Operation INSTALLATION NOTICE: This heater is intended for use as supple- CAUTION: This heater creates warm air currents. mental heat. Use this heater along with your primary These currents move heat to wall surfaces next to heating system. Do not install this heater as your heater. Installing heater next to vinyl or cloth wall primary heat source. If you have a central heating coverings or operating heater where impuriti

Summary of the content on the page No. 8

INSTALLATION Installation and Clearances for Vent-Free Operation (Cont.) 8 INSTALLATION Continued Carefully follow the instructions below. This will ensure safe noncombustible material behind it. Noncombustible material must installation into a masonry, UL127-listed manufactured fireplace, extend at least 8" up (for all models). If noncombustible material is or listed vent-free firebox. less than 12", you must install the fireplace hood accessory (24" and 30" Models Only). See Figure 5 for minim

Summary of the content on the page No. 9

INSTALLATION 9 Mantel Clearances 9 Floor Clearances INSTALLATION Continued MANTEL CLEARANCES Mantel Shelf 10" Underside of In addition to meeting noncombustible material clearances, you must 8" Mantel Shelf also meet required clearances between fireplace opening and mantel 6" 1 shelf. If you do not meet the clearances listed below, you will need a hood. 2 /2" Determining Minimum Mantel Clearance All minimum distances are If you meet minimum clearance between mantel shelf and top of in inches fi

Summary of the content on the page No. 10

INSTALLATION Installing Damper Clamp Accessory for Vented Operation 10 Installing Heater Base Assembly INSTALLATION Continued INSTALLING DAMPER CLAMP ACCESSORY INSTALLING HEATER BASE ASSEMBLY FOR VENTED OPERATION WARNING: You must secure this heater to fire- Note: When used as a vented heater, appliance must be installed place floor. If not, heater will move when you adjust only in a solid-fuel burning fireplace with a working flue and controls. Moving heater may cause a gas leak. constructed o

Summary of the content on the page No. 11

INSTALLATION 11 Installing Heater Base Assembly (Cont.) 11 INSTALLATION Continued 4. For Variable Manually-Controlled and Thermostatically-Con- trolled Models mark screw locations through holes in mount- ing brackets (see Figure 13). For Remote-Ready Models mark screw locations through holes in front panel of base (see Fig- Masonry Screw ure 14). If installing in a brick-bottom fireplace, mark screw locations in mortar joint of bricks. 5. Remove heater base from fireplace. 6. Remove mounting bra

Summary of the content on the page No. 12

INSTALLATION Connecting To Gas Supply 12 INSTALLATION Continued Installation must include an equipment shutoff valve, union, and CONNECTING TO GAS SUPPLY plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figures 16 or WARNING: This appliance requires a 1/2" NPT 17 page 13, depending on your model). (National Pipe Thread) inlet connection to the pres- sure regulator. IMPORTANT: Install equipment shutoff valve in an accessible loca

Summary of the content on the page No. 13

INSTALLATION 13 Connecting to Gas Supply (Cont.) 13 Checking Gas Connections INSTALLATION Continued CSA Design-Certified Equipment CHECKING GAS CONNECTIONS Shutoff Valve With 1/8" NPT Tap* PROPANE/LP From External WARNING: Test all gas piping and connections Regulator for leaks after installing or servicing. Correct all (11" W.C.** Approved Flexible leaks at once. to 14" W.C. Gas Hose (if allowed Pressure) by local codes) WARNING: Never use an open flame to check for a leak. Apply a noncorrosi

Summary of the content on the page No. 14

INSTALLATION Checking Gas Connections (Cont.) 14 Installing Logs INSTALLATION Continued Thermostat Gas Equipment Pressure Testing Heater Gas Connections Valve or Control Shutoff Valve 1. Open equipment shutoff valve (see Figure 18). Valve Location 2. Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve. 3. Make sure control knob of heater is in the OFF position. 4. Check all joints from equipment shutoff valve to thermostat Gas Meter gas valve (Th

Summary of the content on the page No. 15

INSTALLATION 15 Installing Logs (Cont.) 15 INSTALLATION Continued Notch Groove in Peg Rear Log (#3) Back of Log Front Log (#1) Groove Grate in Back Prong of Log Rear Burner Grate Prong Grate Prongs Metal Grate Bar Figure 21 - Installing Front Log (#1) [18" Variable Manually- Controlled Set Shown] Middle Log (#2) Figure 23 - Installing Rear Log (#3) [18" Variable Manually- Controlled Set Shown] Crossover Log (#4) Groove Groove Metal Hole Post Cutout Peg Metal Post Grate Figure 22 - Installing Mid

Summary of the content on the page No. 16

OPERATING HEATER (THERMOSTAT CONTROLLED MODELS) For Your Safety Read Before Lighting 16 Lighting Instructions OPERATING HEATER Note: Home owners generally prefer to operate their heater THERMOSTAT-CONTROLLED MODELS with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full FOR YOUR SAFETY READ flames of the HI heat setting but will find the heat output BEFORE LIGHTING excessive. You can open the chimney damper (if you have one)

Summary of the content on the page No. 17

OPERATING HEATER (THERMOSTAT-CONTROLLED MODELS) 17 To Turn Gas Off To Appliance 17 Thermostat Control Operation Manual Lighting Procedure OPERATING HEATER (MANUALLY-CONTROLLED MODELS) For Your Safety Read Before Lighting Lighting Instructions OPERATING HEATER Continued WHAT TO DO IF YOU SMELL GAS CAUTION: Do not try to adjust heating levels by • Do not try to light any appliance. using the equipment shutoff valve. • Do not touch any electric switch; do not use any phone in your building. • Imme

Summary of the content on the page No. 18

OPERATING HEATER (MANUALLY-CONTROLLED MODELS) Lighting Instructions (Cont.) 18 Variable Control Operation To Turn Gas Off To Appliance Manual Lighting Procedure OPERATING HEATER (REMOTE-READY MODELS) For Your Safety Read Before Lighting OPERATING HEATER Continued 4. Wait five (5) minutes to clear out any gas. Then smell for TO TURN OFF GAS TO APPLIANCE gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information, starting in column 1 of Shutting Off Heater page 1

Summary of the content on the page No. 19

O N O T OPERATING HEATER (REMOTE-READY MODELS) 19 For Your Safety Read Before Lighting (Cont.) 19 Lighting Instructions OPERATING HEATER Continued C. Use only your hand to push in or turn the gas control knob. 1. STOP! Read the safety information, starting in column 2, Never use tools. If the knob will not push in or turn by page 18. hand, don’t try to repair it, call a qualified service techni- 2. Make sure equipment shutoff valve is fully open. cian or gas supplier. Force or attempted repair m

Summary of the content on the page No. 20

OPERATING HEATER (REMOTE-READY MODELS) Lighting Instructions (Cont.) 20 To Turn Gas Off To Appliance Manual Lighting Procedure Optional Remote Operation OPERATING HEATER Continued 8. Keep control knob pressed in for 30 seconds after lighting MANUAL LIGHTING PROCEDURE pilot. After 30 seconds, release control knob. • If control knob does not pop out when released, contact 1. Follow steps 1 through 6 under Lighting Instructions, page 19. a qualified service person or gas supplier for repairs. 2. De


Alternative user manuals
# User manual Category Download
1 Desa 125-R User manual Gas Heater 0
2 Desa BG30P User manual Gas Heater 0
3 Desa 30-80 User manual Gas Heater 0
4 Desa 75-200 User manual Gas Heater 0
5 Desa BG30N User manual Gas Heater 0
6 Desa BG30NT User manual Gas Heater 0
7 Desa BCLP375 User manual Gas Heater 0
8 Desa BG30PT User manual Gas Heater 0
9 Desa 125-RN User manual Gas Heater 0
10 Desa BLP35E User manual Gas Heater 0
11 Desa BVDR18 User manual Gas Heater 1
12 Desa BVDR24 User manual Gas Heater 0
13 Desa BVDR30 User manual Gas Heater 0
14 Desa BVSR18 User manual Gas Heater 0
15 Desa CB36N User manual Gas Heater 0
16 Allied Air Enterprises 506271-01 User manual Gas Heater 0
17 Blue Rhino ALL WEATHER WOVEN HEATER GWU9850F / 35554 User manual Gas Heater 2
18 Breckwell ECONOMY P22FSL User manual Gas Heater 0
19 Breckwell ECONOMY P22FSA User manual Gas Heater 0
20 Breckwell ECONOMY P22I User manual Gas Heater 1