Cleveland Range SD- 450 user manual

User manual for the device Cleveland Range SD- 450

Device: Cleveland Range SD- 450
Category: Hot Beverage Maker
Manufacturer: Cleveland Range
Size: 0.8 MB
Added : 4/19/2013
Number of pages: 18
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Cleveland Range SD- 450. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Cleveland Range SD- 450.

For your convenience

If looking through the Cleveland Range SD- 450 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Cleveland Range SD- 450 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Cleveland Range SD- 450 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Cleveland Range SD- 450 User manual - Online PDF
Advertisement
« Page 1 of 18 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Cleveland Range SD- 450 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Cleveland Range SD- 450. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Operators Manual
Installation, Operation & Service
Direct Steam Table Top Kettles
Table-Top Direct
Steam Kettles
MODELS: KDT- 1- T
KDT- 3- T
KDT- 6- T
KDT-12- T
KDT-20- T
SD Stands
MODELS: SD- 450
SD- 650
SD- 760
SD-1050
SD-1200
SD-1600
SD-1800
Kettles on
SD Stands
MODELS: SD-450- K 6
SD-650- K12
SD-760- K12
SD-760- K20
SD-1050-K 6 6
SD-1200-K 612
SD-1600-K 620
SD-1600-K1212
SD-1600-K1220
SD-1600-K2020
1333 East 179th St., Cleveland, Ohio, U.S.A. 44110

Phone: (216) 481-4900 Fax: (216)

Summary of the content on the page No. 2

TABLE OF CONTENTS Installation General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Inspection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Shipping Damage Instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Clearance Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Kettles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 3

INSTALLATION Note: For SD Stands (with or without kettles) zero GENERAL clearance is required on the sides and back. Installation of the unit must be accomplished by qualified installation personnel working to all applicable local and national codes. Improper KETTLES installation of product could cause injury or damage. This unit is built to comply with applicable Table-top models must be positioned on a firm stand standards for manufacturers. Included among or existing counter top and secured

Summary of the content on the page No. 4

STEAM CONDENSATE (Kettles c/w SD Stands) The stand comes factory plumbed so the condensate All steam plumbing to and from the kettle and is connected to the stands drain manifold. steam boiler should be thoroughly cleaned and inspected for dirt and debris before final connection to the kettle are made. POTABLE WATER Generally, kettles require 1/2" i.p.s. pipe, 10-45 psi steam pressure. If the steam supply pressure The water faucet (optional on kettles purchased exceeds 45 psi, a pressure reduci

Summary of the content on the page No. 5

OPERATING INSTRUCTIONS CLEVELAND STEAM COOKING EQUIPMENT IS INTENDED FOR COMMERCIAL USE ONLY BY PROFESSIONALLY TRAINED PERSONNEL. OPERATION FOR KETTLE/STEAMER COMBINATIONS: 1. Ensure that there is an adequate steam If the boiler in a steamer is supplying steam to a supply to the kettle. kettle, always heat the kettle first. After the kettle contents are heated, and the boiler's steam 2. Turn the steam control valve to pressure returns to normal, the steamer may be the open position by turning

Summary of the content on the page No. 6

CLEANING INSTRUCTIONS 6. Using mild soapy water and a damp sponge, CARE AND CLEANING wash the exterior of the kettle, rinse, and dry. Your kettle must be cleaned regularly to maintain its fast, efficient cooking performance, and to 7. Leave the cover off when the kettle is not in ensure its continued safe, reliable operation. use.. WARNING: Do not use chloride base detergents. 8. If your unit is equipped with a marine lock, clean any food deposits that may have spilled 1. Prepare a warm water

Summary of the content on the page No. 7

SERVICE PARTS STEAM CONTROL ASSEMBLY 30 5 26 14 1 5 23 4 5 4 7 3 8 22 15 1 2 5 3 4 23 16 24 25 4 6 11 7 8 9 28 23 10 1 21 12 13 7 8 29 20 21 9 5 23 19 27 20 5 4 6 18 23 19 7 8 4 9 17 9 6 12 18 7 13 8 17 5

Summary of the content on the page No. 8

STEAM CONTROL ASSEMBLY ITEM NO. PART NO. DESCRIPTION QTY. 1. FA11056 Binding Head Screw, 6-32 x 1/2" lg. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 2. KE50458 End Cap, condensate return . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 3. KE50455-1 Trunnion, condensate return . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 4. FA05002-35 "O" Ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 9

PLUMBING ASSEMBLY 29 (for SD Stands) See Steam Control Drawing See Steam Control Drawing 1 2 S S ST T TE E EA A AM M M 5 I I IN N N 3 22 4 7 21 6 20 C C CO O ON N ND D DE E EN N NS S SA A AT T TE E E 11 R R RE E ET T TU U UR R RN N N 19 10 9 See Steam Control Drawing 8 23 30 18 12 17 13 16 2 1 15 28 14 27 26 1 25 Steam In Configuration for 24 SD Stand with Two Kettles 2 1 S S ST T TE E EA A AM M M I I IN N N 7

Summary of the content on the page No. 10

PLUMBING ASSEMBLY (for SD Stands) ITEM NO. PART NO. DESCRIPTION QTY. 1. FI00169 Tee, 1/2" NPT. (single kettle units) . . . . . . . . . . . . .1 (twin kettle units) . . . . . . . . . . . . . .3 2. KE51723 Pressure Relief Valve, 1/2" NPT (single kettle units) . . . . . . . . . . . . .1 (twin kettle units) . . . . . . . . . . . . . .2 3. FA95010 Jam Nut, #3/4-10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 4. KE51340 Leg . . . . . . . . . . . . . . .

Summary of the content on the page No. 11

FAUCET ASSEMBLIES 1 1 2 2 3 3 4 12 4 5 11 12 6 11 9 7 10 8 9

Summary of the content on the page No. 12

FAUCET ASSEMBLIES ITEM NO. PART NO. DESCRIPTION QTY. 1. KE50825-8 6 gallon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE50825-1 12 gallon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE50825-1 20 gallon . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. FA95022 Retaining Ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 3. FA05002-19 "O" Ring .

Summary of the content on the page No. 13

MAINTENANCE ALL SERVICE MUST BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN. This kettle requires very little preventative maintenance other than daily cleaning. The pressure relief valve must be tested twice a year. PRESSURE RELIEF VALVE MARINE LOCK TESTING PROCEDURE Inspect lock at least twice yearly. 1. Check for excessive play or wear on pivot. WARNING Adjust or replace as required. Kettle will be hot. Use gloves for protection. 2. Insure lock is catching over the centre of the stop pin and

Summary of the content on the page No. 14

TROUBLESHOOTING GUIDE This section contains information intended for use by Authorized Service Personnel only. PROBLEM A/ Kettle heats too slowly or does not come to a boil. Probable Cause Remedy 1. Inadequate steam flow. Check for correct steam using chart below. If kettle is connected to a steamer and powered by a generator the units should be operated sequentially (kettle boiling first, then start steamer). 2. Steam trap not operating properly. The trap should open periodically to dump con

Summary of the content on the page No. 15

SPECIFICATION DRAWINGS KDT-1-T CLEARANCE REQUIREMENTS TO COMBUSTIBLE AND NONCOMBUSTIBLE SURFACES: Right - 4" Left - 0 Back - 0 8.00" 203mm 9.38" 238mm 12.25" 311mm 9.88" 251mm 3.50" 89mm 12.50" 318mm 9.31" 236mm 1.56" 40mm 1/2" NPT 1/2" NPT 8.13" CONDENSATE STEAM 207mm RETURN INLET 13

Summary of the content on the page No. 16

KDT-3-T & KDT-6-T CLEARANCE REQUIREMENTS TO COMBUSTIBLE AND NONCOMBUSTIBLE SURFACES: Right - 4" Left - 4" Back - 1" WALL A B C 1.00" 25mm H STEAM E CONTROL VALVE D 2.25" J 57mm 1.25"/32mm 1/2" NPT CONDENSATE F K 1/2" NPT RETURN STEAM INLET G L NOTE: INLET AND RETURN NOT INTERCHANGABLE M N GAL. LITRE A B C D E F G H J K L M N IN 14.00 10.00 15.13 12.50 8.25 10.00 12.50 23.00 7.00 4.00 11.00 15.00 21.00 3 11 mm 356 254 384 317 210 254 317 584 178 102 279 381 533 IN 17.50 13.38 15.13 15.31 11.00 12

Summary of the content on the page No. 17

KDT-12-T & KDT-20-T CLEARANCE REQUIREMENTS TO COMBUSTIBLE AND NONCOMBUSTIBLE SURFACES: WALL Right - 4" Left - 4" Back - 1.75" A B C 1.75" 45mm H STEAM CONTROL E VALVE MARINE D LOCK 2.25" 57mm J 1.25" 32mm F K L 1/2" NPT CONDENSATE 1/2" NPT RETURN STEAM M G INLET NOTE: INLET AND RETURN NOT INTERCHANGABLE GAL. LITRE A B C D E F G H J K L M IN 20.50 16.75 23.00 22.25 13.50 19.50 22.00 29.00 6.00 8.75 11.50 29.50 3 11 mm 521 425 584 565 343 495 559 737 152 222 292 749 IN 25.25 21.00 27.25 18.00 11.0

Summary of the content on the page No. 18

MODEL A B C SD STANDS WITH 17.70 4.00 10.00 KETTLES SD-450- K 6 450 102 254 25.56 4.00 13.75 SD-650- K12 CLEARANCE REQUIREMENTS TO 650 102 349 COMBUSTIBLE AND 29.94 5.22 15.00 SD-760- K12 760 133 381 NONCOMBUSTIBLE SURFACES: 29.94 3.10 15.00 SD-760- K20 Right - 0 Left - 0 Back - 0 760 79 381 41.32 6.50 34.75 SD-1050- K20 1050 165 883 41.32 4.91 20.66 SD-1050-K 6 6 1050 125 525 47.19 4.10 19.84 SD-1200-K 612 1200 104 504 63 9.88 25.63 SD-1600-K 620 1600 251 651 5.00" 127mm 63 8.25 31.50 13.75" D


Alternative user manuals
# User manual Category Download
1 Cleveland Range (T) MKDL-125-T (-CC) User manual Hot Beverage Maker 0
2 Cleveland Range (T) MKDL-80-T (-CC) User manual Hot Beverage Maker 0
3 Cleveland Range HA-MKDL-100-CC User manual Hot Beverage Maker 2
4 Cleveland Range (T) MKDL-60-T (-CC) User manual Hot Beverage Maker 0
5 Cleveland Range HA-MKDL-100-CCT-RL User manual Hot Beverage Maker 2
6 Cleveland Range (T) MKDL-150-T (-CC) User manual Hot Beverage Maker 1
7 Cleveland Range (T) MKDL-40-T (-CC) User manual Hot Beverage Maker 0
8 Cleveland Range HA-MKDL-150-CCT-RL User manual Hot Beverage Maker 0
9 Cleveland Range HA-MKDL-200-CCT-RL User manual Hot Beverage Maker 0
10 Cleveland Range HA-MKDL-200-CC User manual Hot Beverage Maker 2
11 Cleveland Range HA-MKDL-150-CC User manual Hot Beverage Maker 0
12 Cleveland Range HA-MKDL-300-CCT-RL User manual Hot Beverage Maker 0
13 Cleveland Range HA-MKDL-300-CC User manual Hot Beverage Maker 0
14 Cleveland Range HA-MKDL-60-CC User manual Hot Beverage Maker 0
15 Cleveland Range HA-MKGL-100-CC-T User manual Hot Beverage Maker 0
16 Airlink101 ATVUSB05 User manual Hot Beverage Maker 1
17 Applica K200 User manual Hot Beverage Maker 1
18 Aroma AWK-208BR User manual Hot Beverage Maker 2
19 Aroma AWK-270B User manual Hot Beverage Maker 1
20 Aroma AWK-208P User manual Hot Beverage Maker 1