Cleveland Range MKDL-40-CC user manual

User manual for the device Cleveland Range MKDL-40-CC

Device: Cleveland Range MKDL-40-CC
Category: Hot Beverage Maker
Manufacturer: Cleveland Range
Size: 1.13 MB
Added : 4/19/2013
Number of pages: 43
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Cleveland Range MKDL-40-CC. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Cleveland Range MKDL-40-CC.

For your convenience

If looking through the Cleveland Range MKDL-40-CC user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Cleveland Range MKDL-40-CC on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Cleveland Range MKDL-40-CC to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Cleveland Range MKDL-40-CC User manual - Online PDF
Advertisement
« Page 1 of 43 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Cleveland Range MKDL-40-CC but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Cleveland Range MKDL-40-CC. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Operators Manual
Installation, Operation & Service
Cook/Chill Direct Steam Mixer Kettles
MODELS: MKDL-40-CC
MKDL-60-CC
MKDL-80-CC
MKDL-100-CC
MKDL-125-CC
MKDL-150-CC
1333 East 179th St., Cleveland, Ohio, U.S.A. 44110

Phone: (216) 481-4900 Fax: (216) 481-3782
Visit our web site at www.clevelandrange.com
SE95012 Rev. 1

Summary of the content on the page No. 2

TABLE OF CONTENTS Installation General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Inspection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Shipping Damage Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Clearance Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Recommended Floor Drain Location . . . . . . . . . . . . . . . . . . . . . . 1 Moving Unit . . . .

Summary of the content on the page No. 3

Service Parts Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Lubricator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Remote Control Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Main Console Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Switch Configurat

Summary of the content on the page No. 4

INSTALLATION GENERAL RECOMMENDED FLOOR Installation of the kettle must be accomplished by DRAIN LOCATION qualified installation personnel working to all applicable local and national codes. Improper installation of WALL product could cause injury or damage. This unit is built to comply with applicable standards for 18" CLEARANCE REQUIRED FOR SERVICE manufacturers. Included among those approval agencies are: UL, NSF, ASME/Ntl.Bd., CSA, ETL, CE, and others. Many local codes exist, and it is the

Summary of the content on the page No. 5

Shim as required to make level with center console (front Jack and back) 4"x4" or larger (front and back) Skid Flanged feet Forklift tongs Recommended Installation Procedure MOVING UNIT 1. While still on skid, move unit as close to final 4. Lower gently to ground and remove forklift installation position as possible. and blocking. 2. Prepare unit for lifting as shown in diagram. 5. If unit has to be re-positioned, slide gently. Do not twist or push one side of unit excessively 3. Lift gently wi

Summary of the content on the page No. 6

⇒ D/ Lower bridge. COMPRESSED AIR CONNECTION ⇒ E/ Bridge pins should enter pin hole on kettle Mixer Kettles with an air activated discharge valve perfectly, If not return to step 1 and repeat require a minimum of 90 PSI to operate correctly. leveling steps. If the unit is also supplying air to a Metering Filling ⇒ F/ Raise bridge and swing to far right (for twin Station then a pressure of 100 PSI at a minimum volume mixers only). of 25 CFM is required. ⇒ G/ Repeat steps D and E (for twin mixers

Summary of the content on the page No. 7

DUMP VALVE TO DRAIN PIPING SCHEMATIC CONDENSATE OUT HOT WATER STEAM IN COOLING WATER IN COLD WATER COOLING WATER OUT GLOBE VALVES UNIONS STRAINERS STEAM REQUIREMENTS FOR KETTLES Kettle Cap. Kettle 25 psi Steam 265°F 40 psi Steam 287°F 80 psi Steam 302°F U.S. Gal. Dia. Lbs./Hr. Hp./Hr. Lbs./Hr. Hp./Hr. Lbs./Hr. Hp./Hr. 40 26" 100 3 120 4 150 4.5 60 29.5" 150 4.5 190 5.5 230 7.0 80 33" 210 6.0 260 7.5 300 9.0 100 36" 260 7.5 320 9.5 390 11.0 125 40" 320 9.5 400 11.5 470 14.0 150 40" 390 11.0 480 1

Summary of the content on the page No. 8

QUALITY ASSURANCE CHECKLIST Follow this list only after all other installation steps are completed. Some steps require the use of equipment. Follow operating instructions. The following will be performed before the unit is connected to utilities: 1. Visual Examine unit for scratches, dents, or other defects. 2. Visual Check flanged feet all have bolts holding them. 3. General Check all accessible wiring, mechanical and plumbing connections by hand for secure, tight and satisfactory assembly

Summary of the content on the page No. 9

OPTIONAL CONTROLS Some units may not have the following items to test 13. Meter Complete this test using markings on mixer arm or a measuring strip if there are no markings on the unit. Test the meter at the following values up to capacity (Should be ± approx. 1/4"). During this test check that the (interrupt) switch stops the water flow and the (continue/reset) when switched to "continue" resumes the flow without resetting the meter. GALLONS LITERS 5 20 20 80 40 160 80 320 100 400 When the (

Summary of the content on the page No. 10

OPERATING INSTRUCTIONS Operating Controls & Indicators ITEM NO. DESCRIPTION FUNCTION 1. Air Quick Connect . . . . . . . . .Connection for air to food pump. 2. Air Regulator . . . . . . . . . . . . .Opens and closes air operated product discharge valve (Item 10). 3. Hand Wheel . . . . . . . . . . . . . .Tilts kettle for pouring. May be replaced by tilt switch if unit is power tilt. 4. Steam Valve . . . . . . . . . . . . . .Manually controls the amount of steam entering the kettle. 5. Scraper Blad

Summary of the content on the page No. 11

OFF ON General Operation Operating Suggestions Cleveland Range Mixer Kettles are simple and 1. Turn MAIN POWER SWITCH safe to operate. The following tips will allow you to (26) to "ON". maximize the use of your new mixer. 1. To achieve optimum performance on tilting kettles; OFF Lifting & Lowering MIX LIFT Before applying steam to a cold kettle, open the DRAIN COCK (9) to drain condensate from Bridge the kettles jacket. Close drain cock when unit is WARNING- Insure FAUCET fully

Summary of the content on the page No. 12

Discharge Valve BYPASS ACTIVE Manual Heating/ 1. For air valve: turn AIR Cooling REGULATOR (2) clockwise to 1. Turn ACTIVE/BYPASS SWITCH open, or counterclockwise to (25) to "BYPASS". close. OFF HEAT AUTO COOL 2. Turn CONTROLLER SWITCH 2. For butterfly valve: push (25) to "HEAT" or "COOL". handle in and pull upwards to open. 3. For heat: open STEAM VALVE (4) completely to boil, or adjust to regulate Adding Water temperature. Manually For cooling: open STEAM 1. Locate FAUCET SPOUT (13) VALVE

Summary of the content on the page No. 13

MIXER KETTLE OFF ON Pen OPERATION USING MAN OUT1 OUT2 ALRM Display SP ˚C ˚F U MRC 7000 (1 PEN) Pen1 key - AUTO/MAN Note: Temperature probe on OFF AUTO SCROLL Key mixer bridge must be covered MAN HEAT AUTO COOL UP Key with a minimum of three inches of DOWN Key product to function correctly. 1. Turn MAIN POWER switch to "ON". BYPASS ACTIVE 2. Turn HEAT/COOL switch to "OFF/AUTO". Heat Cooling Manual Output 1 Output 2 Alarm 3. Turn ACTIVE/BYPASS switch to "ACTIVE". MAN OUT1 OUT2 ALRM 4.

Summary of the content on the page No. 14

CLEANING INSTRUCTIONS PRE-PRODUCTION GENERAL SANITIZING PROCEDURE Your Cleveland kettle must be cleaned regularly to maintain its fast, efficient cooking performance, and to ensure its continued safe, reliable operations. NOTE: The kettle must be sanitized ⇒ Always turn off equipment power before prior to the daily production run. using water. ⇒ When cleaning kettle exterior, allow kettle to cool before washing. 1. Fill kettle to hemisphere and start the agitator. ⇒ Never use steel wool for clea

Summary of the content on the page No. 15

6. Put valve in place, and secure with sani- AUTOMATIC DUMP VALVE clamp (1). Daily - clean automatic dump valve as follows: BUTTERFLY VALVE Air regulator Controls air flow to automatic dump valve, 1. Place valve in open position. turn clockwise to open and counterclockwise to close 5 2. Wash using a warm water and mild detergent (extend plunger) Air quick connect solution. Push yellow tab down to 4 release air pressure before 2 disconnecting air hose 3. Use a nylon brush, remove food depos

Summary of the content on the page No. 16

SERVICE PARTS WARRANTY In order to preserve the various agency safety Our Company supports a worldwide network of certification (UL, NSF, ASME/Ntl. Bd., etc.), only Maintenance and Repair Centers. Contact your factory-supplied replacement parts should be nearest Maintenance and Repair Centre for used. The use of other than factory supplied replacement parts, service, or information replacement parts will void warranty. regarding the proper maintenance and repair of your cooking equipment LUBRIC

Summary of the content on the page No. 17

REMOTE CONTROL ASSEMBLY NOTE: See SWITCH CONFIGURATIONS for applicable contact cartridge/capacitor 12 combinations and part numbers 15 2 3 INCLUDED WITH 16 ALL SWITCHES. 7 8 9 5 10 11 9 6 17 1 4 5 6 14 13 ITEM NO. PART NO. DESCRIPTION QTY. 1. KE53257 Digital Counter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. SE50354 Pen Tip, red (pkg. of 5) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 3. SE50354 Pen Tip, green (pkg. of 5)

Summary of the content on the page No. 18

SPEED CONTROL 5 6 4 7 3 8 2 1 9 FAST MIN. MOTOR WILL NOT START UNLESS CONTROL IS AT "MIN." MIXER LIFT OFF OFF MIX LIFT UP DOWN EMERGENCY STOP MAIN CONSOLE CONTROLS 2 1 NOTE: See SWITCH CONFIGURATIONS 6 for applicable contact 7 cartridge/capacitor 9 combinations and 10 part numbers INCLUDED WITH ALL SWITCHES. 11 5 4 12 3 ITEM NO. PART NO. DESCRIPTION QTY. 1. KE52190 Knob, Speed Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2

Summary of the content on the page No. 19

T T F F I I L L SWITCH CONFIGURATION 5 6 4 7 3 8 2 INDEX 1 9 Capacitor Contactor Cartridges FAST MIN. MOTOR WILL NOT START UNLESS CONTROL IS AT "MIN." PART NO. KE52074 KE53138-1 KE53138 NOTE: Refer to Maintenance Section for Switch Disassembly Instructions. OFF ON BYPASS ACTIVE General Operation Manual Heating/ 1. Turn MAIN POWER SWITCH to Cooling "ON". 1. Turn ACTIVE/BYPASS SWITCH to OFF "BYPASS". HEAT AUTO COOL OFF MIX LIFT Lifting & Lowering 2. Turn CONTROLLER SWITCH to "

Summary of the content on the page No. 20

1 HYDRAULIC COMPONENTS 7 6 8 5 9 41 47 10 46 11 4 39 40 43 12 3 38 2 44 13 37 1 14 36 48 15 35 42 34 49 16 30 32 18 19 20 31 21 22 23 29 33 28 24 25 27 26 ITEM NO. PART NO. DESCRIPTION QTY. 1. KE51607 Flow Control Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 2. KE54834-10 Solenoid Valve, 2 Way, 120 Volt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 SE50224 Coil Only 120 Volt . . . . . .


Alternative user manuals
# User manual Category Download
1 Cleveland Range (T) MKDL-125-T (-CC) User manual Hot Beverage Maker 0
2 Cleveland Range (T) MKDL-80-T (-CC) User manual Hot Beverage Maker 0
3 Cleveland Range HA-MKDL-100-CC User manual Hot Beverage Maker 2
4 Cleveland Range (T) MKDL-60-T (-CC) User manual Hot Beverage Maker 0
5 Cleveland Range HA-MKDL-100-CCT-RL User manual Hot Beverage Maker 2
6 Cleveland Range (T) MKDL-150-T (-CC) User manual Hot Beverage Maker 1
7 Cleveland Range (T) MKDL-40-T (-CC) User manual Hot Beverage Maker 0
8 Cleveland Range HA-MKDL-150-CCT-RL User manual Hot Beverage Maker 0
9 Cleveland Range HA-MKDL-200-CCT-RL User manual Hot Beverage Maker 0
10 Cleveland Range HA-MKDL-200-CC User manual Hot Beverage Maker 2
11 Cleveland Range HA-MKDL-150-CC User manual Hot Beverage Maker 0
12 Cleveland Range HA-MKDL-300-CCT-RL User manual Hot Beverage Maker 0
13 Cleveland Range HA-MKDL-300-CC User manual Hot Beverage Maker 0
14 Cleveland Range HA-MKDL-60-CC User manual Hot Beverage Maker 0
15 Cleveland Range HA-MKGL-100-CC-T User manual Hot Beverage Maker 0
16 Airlink101 ATVUSB05 User manual Hot Beverage Maker 1
17 Applica K200 User manual Hot Beverage Maker 1
18 Aroma AWK-208BR User manual Hot Beverage Maker 2
19 Aroma AWK-270B User manual Hot Beverage Maker 1
20 Aroma AWK-208P User manual Hot Beverage Maker 1