Charnwood DX20i MkII user manual

User manual for the device Charnwood DX20i MkII

Device: Charnwood DX20i MkII
Category: Gas Heater
Manufacturer: Charnwood
Size: 0.22 MB
Added : 4/2/2014
Number of pages: 11
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Charnwood DX20i MkII. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Charnwood DX20i MkII.

For your convenience

If looking through the Charnwood DX20i MkII user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Charnwood DX20i MkII on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Charnwood DX20i MkII to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Charnwood DX20i MkII User manual - Online PDF
Advertisement
« Page 1 of 11 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Charnwood DX20i MkII but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Charnwood DX20i MkII. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

CHARNWOOD
DX20i MkII
Multifuel Roomheater
Operating
and
Installation Instructions
Bishops Way, Newport, Isle Of Wight, PO3O 5WS, U.K.
Tel: (01983) 537799 Fax: (01983) 537788

Summary of the content on the page No. 2

OPERATING INSTRUCTIONS FOR THE CHARNWOOD DX20i MKII GENERAL POINTS whether you are in a smoke control will also result in considerably area, then please check with your reduced outputs. The wood should be Before lighting the fire check with Local Authority. cut and split and then left to season the installer that the work and checks in a well ventilated dry place for at described in the installation least one year but preferably two Smokeless Fuels instructions have been carried out years before

Summary of the content on the page No. 3

Open the main doors Open the ashpit (marked on the handle of the tool) door Close the ashpit door Close the until the tool is vertical. The grate is main doors put into the solid fuel position by moving the tool in the direction of the arrow "C" until the tool is MULTIFUEL GRATE horizontal. Airwash Control Your Charnwood is fitted with a Closed Open multifuel grate which enables solid If a mixture of wood and solid fuel, fuel, wood and peat to be burned or peat and solid fuel, is to be burnt equ

Summary of the content on the page No. 4

For safety reasons, if the fire is to be using solid fuel do not go beyond the REFUELLING left unattended with the doors open 45° position as this can cause the then use a spark guard which grate to jam. complies with BS 3248. Keep the firebox well filled (the fuel If jamming does occur then the fire may be sloped up from the front should be allowed to burn for firebars), but do not allow fuel to ASH CLEARANCE approximately half an hour before spill over the top of the front fire The ashpan must

Summary of the content on the page No. 5

THROAT PLATE AND CLEANING AND CHIMNEY SWEEPING FLUEWAY CLEANING MAINTENANCE The chimney should be swept at least It is important that the throat plate The appliance is finished in vitreous twice a year. In most installations it and all the appliance flueways are enamel. To clean the surfaces simply will be possible to sweep the chimney kept clean. When burning smokeless wipe over with a dry cloth. Abrasive through the appliance. fuels they should be cleaned monthly. pads and scouring cleaners mu

Summary of the content on the page No. 6

emission is flueway or chimney should cause the chimney fire to go Fire Blazing Out Of blockage. For your own safety these out in which case the control should Control. must be kept clean. be kept at the minimum setting until the fire in the appliance has gone out. Check that: The chimney and flueways should Door Glass Blacks Up a) the doors are tightly closed, then be cleaned. If the chimney fire b) the thermostat knob is turned Keeping the glass clean requires a does not go out when the above

Summary of the content on the page No. 7

CHARNWOOD DX20i INSTALLATION INSTRUCTIONS HEALTH AND SAFETY Sunbrite Doubles at a rate of 1.0 be fitted in accordance with the PRECAUTIONS kg/hr with the doors closed over a 4 manufacturers instructions and hourly re-fuelling interval. Building Regulations. WARNING Please take care when installing the appliance that the There is an optional add-in domestic Single wall flue pipe is suitable for requirements of the Health and Safety hot water boiler available with an connecting the appliance to th

Summary of the content on the page No. 8

appliance. In some situations it may storage cylinder to BS:1566 part 1 be necessary to shield the beam or should be used in most situations, mantelpiece to protect it. unless the appliance is to be fitted in a soft water area in which case a direct hot water cylinder may be used PREPARATION OF provided that the boiler is glass lined. FIREPLACE ThisDimension IsThe All pipework in the primary circuit Minimum Level Area Required To Enable The Before fitting the appliance into an must be 28mm diame

Summary of the content on the page No. 9

same side as the boiler tappings. One that the legs of the elbow are recommended mix is six volumes of of the original side firebricks is fitted different lengths to enable some vermiculite granules to one volume of on the other side, and the rear situations to be catered for by turning portland cement thoroughly mixed firebrick is discarded. The firebricks the elbow around. together. Enough water should be must be fire cemented into position, added so that no more than one or wetting the firebo

Summary of the content on the page No. 10

The free inset method of installation PRE LIGHTING may be used instead of infilling. Flap Just Closed With CHECK Details are available on request. Knob Set To Minimum Before initial lighting check the THERMOSTAT following points: Before lighting the fire check the cold setting distance of the 1. The bottom grate bars must all be thermostat. fitted and should move freely and easily when the riddling mechanism With the control knob at the is operated. minimum setting the flap should be just closed

Summary of the content on the page No. 11

400 150 i/d 84 260 Optional Boiler May BeFitted WithThe1" B.S.P. MaleTappings OnTheLeft Or TheRight. 620 150º 604 547 506 405 265 200 260 120 CharnwoodDX20i MkII Overall Dimensions (Dimensionsare in mm) Page 11 HV 7/96


Alternative user manuals
# User manual Category Download
1 Charnwood SLX20 User manual Gas Heater 0
2 Allied Air Enterprises 506271-01 User manual Gas Heater 0
3 Blue Rhino ALL WEATHER WOVEN HEATER GWU9850F / 35554 User manual Gas Heater 2
4 Breckwell ECONOMY P22FSL User manual Gas Heater 0
5 Breckwell ECONOMY P22FSA User manual Gas Heater 0
6 Breckwell ECONOMY P22I User manual Gas Heater 1
7 Briggs & Stratton 32K400 User manual Gas Heater 2
8 Bryan Boilers CLM240WP User manual Gas Heater 2
9 Bryan Boilers CLM180WP User manual Gas Heater 0
10 Bryan Boilers CLM270WP User manual Gas Heater 1
11 Bryan Boilers CLM300WP User manual Gas Heater 0
12 Bryan Boilers CLM90WP User manual Gas Heater 0
13 Cannon CANTFS-03-NG User manual Gas Heater 0
14 Cannon CANTFS-03-LP User manual Gas Heater 0
15 Bryant 585A/YAC User manual Gas Heater 7