Carrier 48MA/50ME016-040 user manual

User manual for the device Carrier 48MA/50ME016-040

Device: Carrier 48MA/50ME016-040
Category: Heating System
Manufacturer: Carrier
Size: 0.9 MB
Added : 8/8/2014
Number of pages: 48
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Carrier 48MA/50ME016-040. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Carrier 48MA/50ME016-040.

For your convenience

If looking through the Carrier 48MA/50ME016-040 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Carrier 48MA/50ME016-040 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Carrier 48MA/50ME016-040 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Carrier 48MA/50ME016-040 User manual - Online PDF
Advertisement
« Page 1 of 48 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Carrier 48MA/50ME016-040 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Carrier 48MA/50ME016-040. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

48MA/50ME016-040
Combination Multizone Heating/Cooling Units
Gas, Electric, or Glycol Heat
Installation, Start-Up
and Service Instructions
Cleaning....................................39
CONTENTS
• EVAPORATOR COILS (ZONE COOLING COILS)
Page
AND GLYCOL HEATING COILS
SAFETY CONSIDERATIONS...................2
• CONDENSERAND OUTDOOR-AIR COOLING
COILS
INSTALLATION .............................2-34
• CONDENSATE DRAINS
General......................................2
• INDOOR-AIR FILTERS
Unit Clearances..

Summary of the content on the page No. 2

SAFETY CONSIDERATIONS INSTALLATION Installation and servicing of air-conditioning equipment General— Install unit on rooftop, outdoor site only. In- canbehazardousduetosystempressureandelectricalcom- stallunit,electricalwiring,gassupplyline(48MA)andcon- ponents.Onlytrainedandqualifiedservicepersonnelshould densate drain lines in accordance with all applicable codes. install, repair, or service air-conditioning equipment. Untrainedpersonnelcanperformbasicmaintenancefunc- Unit Clearances — See Fig.

Summary of the content on the page No. 3

CONDENSER SECTIONAIRFLOW CONN — Connection NOTES: 1. Space required for service and airflow all around and above unit is 36 inches. 2. For additional information see Fig. 4. 3. Centerofgravityiswithin6in.radiusofgeo- metric center of unit. 1 4. Maximumallowablepitchofunitis ⁄2in.per 10 ft in any direction. Certified dimension drawings available on request. DIMENSIONS (ft-in.) UNIT 48MA AB C D E F G H J K L 3 5 5 15 1 1 3 1 1 1 016-030 7- 2 ⁄4 3-0 ⁄8 17-11 ⁄16 2-2 ⁄16 13-5 ⁄2 0- 9 ⁄16 2-10 7-3 ⁄16

Summary of the content on the page No. 4

CONDENSER SECTIONAIRFLOW CONN — Connection NOTES: 1. Space required for service and airflow all around and above unit is 36 inches. 2. For additional information see Fig. 5. 3. Centerofgravityiswithin6in.radiusofgeo- metric center of unit. 1 4. Maximumallowablepitchofunitis ⁄2in.per 10 ft in any direction. Certified dimension drawings available on request. DIMENSIONS (ft-in.) UNIT 50ME A B C D EF GH J 3 9 5 15 1 1 3 1 1 016-030 7- 2 ⁄4 3-0 ⁄16 17-11 ⁄16 2-2 ⁄16 13-5 ⁄2 3-7 ⁄16 7-3 ⁄16 0-3 ⁄8 0-3 ⁄

Summary of the content on the page No. 5

AIRFLOW *Factory supplied (with accessory roof curb). †Field supplied (when using accessory roof curb). NOTE: Dimensions are in inches. Fig. 3 — Roof Curb Detail Rigging Unit — Inspect unit for shipping damage, and Field-Fabricated Ductwork — Supply- and return- file any damage claim immediately with transportation airopeningsareshowninFig.4and5.Tosimplifysupply- company. air connection, a zone duct plenum may be field fabricated as shown in Fig. 7. It is recommended that this plenum be Liftunitwi

Summary of the content on the page No. 6

Table 1 — Physical Data UNIT 48MA/50ME 016 024 028 030 034 040 Zone Modules (Quantity) 8 8 10 10 12 12 Nominal Cooling Capacity (tons) 15 20 25 28 30 37 OPERATING WEIGHT (lb) Base Unit 48MA 3395 3815 4075 4080 5340 5710 Base Unit 50ME (with electric heat) 2995 3415 3675 3680 4900 5270 Roof Curb 506 506 506 506 630 630 REFRIGERANT CHARGE — R-22 (lb) 28 32 43 43 57 66.1 COMPRESSOR Reciprocating Hermetic, 1725 Rpm No. 1 Type 06DE537 06DE824 06DE537 06DE537 06DE537 06EE250 Cylinders...Unloaders 6...

Summary of the content on the page No. 7

EVAPORATOR (ZONE MODULE)AIRFLOW CONN — Connection *Not used on 48MA016,024 (8 zone module units). NOTES: 1. For additional information, see Table 1 and Fig. 1. 1 2. Maximum allowable unit pitch is ⁄2 in. per 10 ft in any direction. 3. Remove shipping brace before assembling curb section (location shown). DIMENSIONS (ft-in.) UNIT 48MA ABC D E F G H J 1 1 7 9 9 3 1 016-030 18-2 ⁄8 7- 3 11-9 5-6 ⁄4 7-2 ⁄8 1-10 ⁄16 2-2 ⁄16 6-0 ⁄8 0- 7 ⁄2 7 3 3 7 3 1 1 5 034,040 21-9 ⁄8 7-11 ⁄4 14-1 ⁄4 6-7 ⁄16 8-4 ⁄1

Summary of the content on the page No. 8

EVAPORATOR (ZONE MODULE)AIRFLOW CONN — Connection *Not used on 50ME016,024 (8 zone module units). END DETAIL (034,044 12-ZONE MODULES) NOTES: 1. For additional information, see Table 1 and Fig. 2. 1 2. Maximum allowable unit pitch is ⁄2 in. per 10 ft in any direction. 3. Remove shipping brace before assembling curb section (location shown). DIMENSIONS (ft-in.) UNIT 50ME ABC D E F G H J 1 1 7 9 9 3 1 016-030 18-2 ⁄8 7- 3 11-9 5-6 ⁄4 7-2 ⁄8 1-10 ⁄16 2-2 ⁄16 6-0 ⁄8 0- 7 ⁄2 7 3 3 7 3 1 1 5 034,040 2

Summary of the content on the page No. 9

Donotinterconnectdrains.Makeeachtrapaminimumof CondensateDrains— Pipenipplescoveredwithfoam 4 in. deep. Insulate trap against freeze-up or use flexible rubber insulation are shipped in unit return air filter section material. (6 nipples in units 48MA, 4 nipples in units 50ME). Install anippleineachdrainconnectiononbothsidesofunit.See Gas Piping (48MA) — Unit is equipped for use with Fig. 1 and 2 for drain locations. Be sure foam rubber seals type of gas shown on nameplate. Refer to latest edition

Summary of the content on the page No. 10

Allunitshaveamainpowersupplyterminalboardinthe power and condensing control box. The electric resistance heaterpowersupplyterminalboard(s)(ifunitissoequipped) on 50ME units is located in the heater control box at front of unit. See Fig. 2, 5, and 9. All terminal boards are suitable for use with copper or aluminum wire. Connectelectricalconduit(athreadedpipenipple)shipped withunittothreadedfittinginroofcurbandbottomofmain powerandcondensingsectioncontrolbox.Routemainpower wiresthroughconduittoterm

Summary of the content on the page No. 11

Use the following formula to determine the percent volt- IMPORTANT: If the supply voltage phase imbalance age imbalance. ismorethan2%,contactyourlocalelectricutilitycom- % Voltage Imbalance: pany immediately. max voltage deviation from average voltage = 100 × average voltage Unitfailureasaresultofoperationonimproperlinevolt- ageorexcessivephaseimbalanceconstitutesabuseandmay EXAMPLE: Supply voltage is 460-3-60. cause damage to electrical components. See Tables 2-5 for AB = 452 v unit, electric h

Summary of the content on the page No. 12

Table 3 — Unit 50ME Electrical Data VOLTAGE COMP COMP OFM POWER IFM UNIT VOLTAGE RANGE NO. 1 NO. 2 FLA SUPPLY 50ME (3 Ph, 60 Hz) Min Max RLA LRA RLA LRA No. 1 No. 2 No. 3 Hp FLA MCA MOCP 208/230 187 254 63.6 266 6.6 16.2 109.6 125 016 460 414 508 28.6 120 — — 6.2 3.0 —5 6.6 49.5 60 575 518 632 22.8 96 2.4 5.6 39.6 45 208/230 187 254 44.4 170 44.4 170 6.6 24.2 138.0 150 024 460 414 508 19.9 77 19.9 77 6.2 3.0 — 7.5 11.0 61.9 70 575 518 632 15.7 62 15.7 62 2.4 9.0 49.2 60 208/230 187 254 63.6 266

Summary of the content on the page No. 13

Table 5 — Unit 50ME Electrical Application Data MCA UNIT kW Heating 50ME NOMINAL Unit (Unit Circuit VOLTAGE Cooling Common Total) IFM Feed Size 12 Hp 43/ 53 150.0/165.6 — 184.8/192.6 208/230 57/ 70 109.8/109.8 200.0/220.9 — 216.7/237.6 87/106 150.0/165.8 150.0/165.8 316.7/348.3 016 5 53 82.9 90.9 460 70 49.5 110.5 — 117.1 106 165.8 172.4 575 106 39.6 132.5 — 138.1 43/ 53 150.0/160.6 — 213.0/220.8 208/230 57/ 70 138.0/138.0 200.0/220.9 — 238.0/248.5 87/106 150.0/165.8 150.0/165.8 342.2/359.0 024

Summary of the content on the page No. 14

quick-connecttypemultiplexingterminals.Thispreventsover- Field Control Wiring loadingthenestcontroltransformers.Factory-suppliedjump- ZONE THERMOSTATS — Install a Carrier approved ac- erswithquick-connectterminalsareshippedinthezonecon- cessoryzonethermostatassemblyineachzoneaccordingto trol and thermostat panel compartment. installationinstructionsincludedintheaccessory.Locateeach Undernocircumstancesshallthetransformerpowerfrom thermostatassemblyinthespacewhereitwillsenseaverage oneClassIIcirc

Summary of the content on the page No. 15

Fig. 10 — Zone Control Board Component Location (cont) 15

Summary of the content on the page No. 16

LEGEND *One for each module. C— Contactor NOTES: CR — Control Relay 1. COOLING GV — Gas Valve HA — HeatAnticipator Stage 1 — First stage of modules 1 and 2 HR — Heating Relay HEATING TC — Thermostat, Cooling TH — Thermostat, Heating Stage 1 — First stage of modules 1 and 2 TRAN — Transformer 2. Set heat anticipator (HA1) at .26. Screw Terminal Quick-Connect Terminal Factory Control Wires Printed Circuit Field Wiring Fig. 11 — 48MA; One-Stage Heat, One-Stage Cool — 2 Nested Modules, Joint Zone Co

Summary of the content on the page No. 17

LEGEND *One for each module. C— Contactor NOTES: CR — Control Relay 1. COOLING GV — Gas Valve HA — HeatAnticipator Stage 1 — First stage of modules 1 and 2 HR — Heating Relay HEATING TC — Thermostat, Cooling TH — Thermostat, Heating Stage 1 — First stage of modules 1 and 2 TRAN — Transformer 2. Set heat anticipator (HA1) at .26. Screw Terminal Quick-Connect Terminal Factory Control Wires Printed Circuit Field Wiring Fig. 12 — 48MA; One-Stage Heat, Two-Stage Cool — 2 Nested Modules, Joint Zone Co

Summary of the content on the page No. 18

LEGEND *One for each module. C— Contactor NOTES: CR — Control Relay 1. COOLING GV — Gas Valve HA — HeatAnticipator Stage 1 — First stage of modules 1, 2, and 3 HR — Heating Relay HEATING TC — Thermostat, Cooling TH — Thermostat, Heating Stage 1 — First stage of modules 1, 2, and 3 TRAN — Transformer 2. Set heat anticipators (HA1) at .13. Screw Terminal Quick-Connect Terminal Factory Control Wires Printed Circuit Field Wiring Fig.13—48MA;One-StageHeat,One-StageCool—OneIndependentModule,2JointModu

Summary of the content on the page No. 19

LEGEND *One for each module. C— Contactor NOTES: CR — Control Relay 1. COOLING GV — Gas Valve HA — HeatAnticipator Stage 1 — First stage of modules 1, 2, and 3 HR — Heating Relay Stage 2 — Second stage of modules 2 and 3 TC — Thermostat, Cooling HEATING TH — Thermostat, Heating TRAN — Transformer Stage 1 — First stage of modules 1, 2, and 3 Screw Terminal 2. Set heat anticipators (HA1) at .13. Quick-Connect Terminal Factory Control Wires Printed Circuit Field Wiring Fig. 14 — 48MA; One-Stage Hea

Summary of the content on the page No. 20

LEGEND *One for each module. C— Contactor NOTES: CR — Control Relay 1. COOLING GV — Gas Valve HA — HeatAnticipator Stage 1 — First stage of modules 1, 2, 3, and 4 HR — Heating Relay HEATING TC — Thermostat, Cooling TH — Thermostat, Heating Stage 1 — First stage of modules 1, 2, 3, and 4 TRAN — Transformer 2. Set heat anticipator (HA1) at .26. Screw Terminal Quick-Connect Terminal Factory Control Wires Printed Circuit Field Wiring Fig. 15 — 48MA; One-Stage Heat, One-Stage Cool — 4 Module Joint Zo


Alternative user manuals
# User manual Category Download
1 Carrier 48LJE User manual Heating System 9
2 Carrier 48DD User manual Heating System 4
3 Carrier 48NET User manual Heating System 2
4 Carrier 48NHT User manual Heating System 8
5 Carrier 48MPD User manual Heating System 1
6 Carrier 48LJD User manual Heating System 1
7 Carrier 48DJD User manual Heating System 5
8 Carrier 48DJE User manual Heating System 11
9 Carrier 48NVT User manual Heating System 1
10 Carrier 48NLT User manual Heating System 3
11 Carrier 48PD05 User manual Heating System 1
12 Carrier 48NMT User manual Heating System 0
13 Carrier 48PG03---16 User manual Heating System 1
14 Carrier 48TJE004-014 User manual Heating System 8
15 Carrier 48TJF004-012 User manual Heating System 9
16 Allied Air Enterprises 506299-01 User manual Heating System 1
17 Amtrol User manual Heating System 3
18 Atmos Energy HE26 User manual Heating System 0
19 Atmos Energy INTERCOMBI HE32 User manual Heating System 6
20 Bard Mfg. Co.EHP513-A10 User manual Heating System 1