Summary of the content on the page No. 1
HP 8935 CDMA Cellular/PCS Base Station
Test Set
Reference Guide
Firmware Version: A.01.00 and above
HP Part Number E6380-90019
Revision A
Printed in U.S.A.
November 1997
© Copyright 1997 Hewlett-Packard Company
Summary of the content on the page No. 2
Notice Information contained in this document is subject to change without notice. All Rights Reserved. Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. This material may be reproduced by or for the U.S. Government pursuant to the Copyright License under the clause at DFARS 52.227-7013 (APR 1988). 2
Summary of the content on the page No. 3
Contents Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 In This Book. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Conventions Used in this Book . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 1. Getting Started Before Connecting a Radio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Changing the Test Set’s Display. . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 4
Contents Transfer Stored Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 SA (spectrum analyzer) Self Calibration ON/OFF . . . . . . . . . . . . . . 65 Catalog PC (Memory) Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Set Up Printer/Data Collection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Using the Code Domain Analyzer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Selecting the Code Domain Analyzer’s Con
Summary of the content on the page No. 5
Contents Freq Err. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 Gain. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 Gen Dir . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 Gen Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 Gen Special . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 6
Contents AFGen1 To . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 AFGen2 Freq. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 AFGen2 To . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 Amplitude . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 Atten Hold. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 7
Contents Sensitivity (spectrum analyzer). . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 Settling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151 Span. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151 Speaker ALC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 Speaker Vol. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 8
Contents Parity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172 Printer Port: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172 Print Title:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172 Range Hold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173 Ref Select. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 9
Contents Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197 External Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197 Manuals (English and non-English) . . . . . . . . . . . . . . . . . . . . . . . . 197 Test Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 10
Contents 10
Summary of the content on the page No. 11
Product Information 11
Summary of the content on the page No. 12
Manufacturer’s This statement is provided to comply with the requirements of the Declaration German Sound Emission Directive, from 18 January 1991. This product has a sound pressure emission (at the operator position) < 70 dB(A). • Sound Pressure Lp < 70 dB(A). • At Operator Position. • Normal Operation. • According to ISO 7779:1988/EN 27779:1991 (Type Test). Herstellerbescheinigung Diese Information steht im Zusammenhang mit den Anforderungen der Maschinenlärminformationsverordnung vom 18 Ja
Summary of the content on the page No. 13
Safety GENERAL Considerations This product and related documentation must be reviewed for familiarization with safety markings and instructions before operation. This product has been designed and tested in accordance with IEC Publication 1010, "Safety Requirements for Electronic Measuring Apparatus," and has been supplied in a safe condition. This instruction documentation contains information and warnings which must be followed by the user to ensure safe operation and to maintain the pro
Summary of the content on the page No. 14
Safety Considerations for this Instrument WARNING This product is a Safety Class I instrument (provided with a ! protective earthing ground incorporated in the power cord). The mains plug shall only be inserted in a socket outlet provided with a protective earth contact. Any interruption of the protective conductor inside or outside of the product is likely to make the product dangerous. Intentional interruption is prohibited. Do not expose to or operate this instrument in outdoor ! atmos
Summary of the content on the page No. 15
Servicing instructions are for use by qualified personnel only. To avoid electrical shock, do not perform any servicing unless you are qualified to do so. The opening of covers or removal of parts is likely to expose dangerous voltages. Disconnect the product from all voltage sources while it is being opened. Adjustments described in the manual are performed with power supplied to the instrument while protective covers are removed. Energy available at many points may, if contacted, result
Summary of the content on the page No. 16
CERTIFICATION Hewlett-Packard Company certifies that this product met its published specifications at the time of shipment from the factory. Hewlett-Packard further certifies that its calibration measurements are traceable to the United States National Institute of Standards and Technology, to the extent allowed by the Institute’s calibration facility, and to the calibration facilities of other International Standards Organization members. WARRANTY This Hewlett-Packard instrument product i
Summary of the content on the page No. 17
Table 1 Regional Sales and Service Offices Eastern USA Eastern USA Midwestern USA Sales Office Sales Office Sales and Service Hewlett-Packard Company Hewlett-Packard Company Hewlett-Packard Company 2101 Gather Rd. 2101 Gather Rd. 5201 Tollview Drive Rockville, MD 20850 Rockville, MD 20850 Rolling Meadows, IL 60008 Tel: (301) 258-2000 Tel: (301) 258-2000 Tel: (708) 342-2000 Southern USA Southern USA Western USA Sales and Service Service Center Service Center Hewlett-Packard Company Hewlett-Packar
Summary of the content on the page No. 18
Asia Japan International Sales Branch Headquarters Sales and Service Sales and Service Sales and Service Hewlett-Packard Asia Ltd. Yokogawa-Hewlett-Packard Ltd. Hewlett-Packard S.A. 22-30/F Peregrine Tower 3-29-21, Takaido-Higashi 39 Rue Veyrot Lippo Center Suginami-Ku, Tokyo 168 P.O. Box 365 89 Queensway, Central Telephone: 81 3 3331-6111 1217 Meyrin 1 Hong Kong Fax: 81 3 3331-6631 Geneva, Switzerland G.P.O. Box 863 Hong Kong Telephone: 41-22-780-4111 Telephone: 852-848-7777 Fax: 41-22-780-477
Summary of the content on the page No. 19
Product Description The HP 8935 CDMA Cellular/PCS Base Station Test Set offers full signal generation and analysis capability and support for cellular frequency bands and international PCS frequency bands. You can perform the following CDMA measurements using the Test Set: • Signal Quality Measurements • Rho (ρ) • Time Offset • Frequency Error • Carrier Feedthrough • Code Domain Measurements • Code Domain Power • Code Domain Timing • Code Domain Phase • Average Power • Channel Power • Error
Summary of the content on the page No. 20
In This Book • Chapter 1, “Getting Started,” on page 23 familiarizes you with the front panel controls. It introduces the different types of control fields that are used to make measurements • Chapter 2, “Operating Overview,” on page 33 provides general information about how to change measurement screens and change control field settings. This chapter also provides some utility procedures: calibrating channel power, setting a reference, setting measurement limits, setting a generator/ana