Bosch Appliances D7024 user manual

User manual for the device Bosch Appliances D7024

Device: Bosch Appliances D7024
Category: Smoke Alarm
Manufacturer: Bosch Appliances
Size: 0.54 MB
Added : 2/24/2014
Number of pages: 22
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bosch Appliances D7024. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bosch Appliances D7024.

For your convenience

If looking through the Bosch Appliances D7024 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bosch Appliances D7024 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bosch Appliances D7024 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bosch Appliances D7024 User manual - Online PDF
Advertisement
« Page 1 of 22 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bosch Appliances D7024 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bosch Appliances D7024. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

D7024 Fire Alarm Control/Communicator
Operation and Installation Guide Addendum



This addendum (P/N: 41740) is intended to replace pages 5, 10, 11, 12, 20, 22, 52, 66, and 78
through 81 of the D7024 Reference Guide (P/N: 31499). Use this addendum to wire the
special 220 VAC, 50 Hz transformer in the control panel. For all other accessories,
programming instructions and tables, refer to the D7024 Reference Guide (P/N: 31499).

© 2005 Bosch Security Systems
130 Perinton Parkway, Fairp

Summary of the content on the page No. 2

D7024 Operation and Installation Guide 41740F Page 2 © 2005 Bosch Security Systems

Summary of the content on the page No. 3

D7024 Contents 7.6.1.2 Format............................................................................................................................................................. 63 7.6.1.3 Account Numbers ........................................................................................................................................... 63 7.6.1.4 Tone.............................................................................................................................

Summary of the content on the page No. 4

D7024 Contents Figures Figure 1: D7024 Control Board.............................................................................................................................................10 Figure 2: Supplemental Reporting........................................................................................................................................14 Figure 3: Enclosure Installation .............................................................................................

Summary of the content on the page No. 5

D7024 Notices 1.3 Industry Canada Notice The Industry Canada label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational, and safety requirements. Industry Canada does not guarantee the equipment will operate to the user’s satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment m

Summary of the content on the page No. 6

D7024 Overview 2.0 Overview 2.1 System Overview The D7024 Control/Communicator is a fully integrated hard-wire fire alarm system. It can support four input points (expandable to 255 using D7039 Multiplex Expansion Module and the D7034 Four-Point Expander) and 16 individual users (expandable to 100 with the D7039). The control panel has a built-in LCD keypad, and up to four additional keypads may be used to provide user interface with the system and programming access for the installer.

Summary of the content on the page No. 7

D7024 Overview 2.2 Specifications Temperature Storage and Operating Temperature: +32° to +120°F (0° to +49°C) Power Input Power: 120 V, 60 Hz, 1.5 A (max. 2 0 A fused supply circuit) Notification Appliance Circuit (NAC) Power: Each NAC has 24 VDC nominal, unfiltered (special application) power with up to 2.5 A capacity (but limited by overall 4.0 A capacity). Refer to Technogram P/N: 34950 for compatible NAC devices. Auxiliary Power: 24 VDC nominal, unfiltered, 1.0 A (special applica

Summary of the content on the page No. 8

D7024 Overview 2.2.1 On-board Conventional Points All on-board points, and points implemented with the D7034 work with two- or four-wire detectors. The system has an optional alarm verification feature. Number of 2-wire Circuits 4 circuits, expandable to 8 using a D7034 Expander Type of Circuit Class B, Style B (use a D7014 Class A Zone Converter to convert to Class A, Style D as needed) EOL Resistor 2.21k ohms (P/N: 25899, UL listed) Supervisory Current 8 to 20 mA Required Current f

Summary of the content on the page No. 9

D7024 Overview Notes: D7024 Operation and Installation Guide © 2005 Bosch Security Systems Page 19 41740F

Summary of the content on the page No. 10

D7024 Installation and Setup 3.0 Installation and Setup Mounting Holes In the shipping box, you should find: • One D7024 Control/Communicator in static- control panel location resistant bag • One Enclosure with transformer ground retainer holes wire for standoffs • One hardware pack • One enclosure lock, washer, and keys • Six End-of-Line (EOL) resistors retainer holes for support posts The hardware necessary for installing the control panel in the enclosure is located in the hardware

Summary of the content on the page No. 11

D7024 Installation and Setup 3.3 Installing Optional Equipment There are two expansion options that connect directly to the panel, and are automatically detected and supervised when the panel is re-powered: • D7034 Four Point Expander • D7039 Multiplex Expansion Module When the panel is first re-powered after installing one of these options, the panel will display one of the following windows: 4Z EXP DETECTED PRESS CLEAR KEY NAC EXP DETECTED PRESS CLEAR KEY MUX DETECTED PRES

Summary of the content on the page No. 12

D7024 Control Terminal Connections 4.0 Control Terminal Connections Incorrect connections may result in damage R2 to the unit and personal injury. HR2 Phone Line 2 CAUTION (Supervised) HT2 Before servicing this equipment, remove all power including the transformer, battery and phone lines. T2 WARNING R1 Shared cable is not recommended for option bus, Phone Line 1 RH1 (Supervised) telephone or NAC wiring. IMPORTANT TH1 T1 Typical Fire Wiring Loop Power Loop Smoke Smoke Input + Input Power

Summary of the content on the page No. 13

D7024 Panel Programming These menu items are only allowed at the local keypad. The following window will appear: OPTION BUS (M/M) 1- UPDATE BUS 2- SETUP KEYPDS Press [1] to program system to update bus. After you have programmed Update Bus, the following window will appear: UPDATE COMPLETE TOT BUS DEVS: X Then the previous window will appear. 7.3.3.2 Setup Keypad Shortcut: 0-PROG, 3-PROG SYSTEM, 4-OPTION BUS This feature tells the system how many keypads should be supervi

Summary of the content on the page No. 14

D7024 Panel Programming Press [2] to select remote PIN. The following window will appear: REMOTE KYPD PIN? ____: YES (1) NO (2) Press the number key that corresponds to your selection and press [#]. The current setting is displayed in front of the colon on the second line. After you select the PIN requirement, the previous window will display. A PIN can be required before operations can be performed using the remote keypads on the option bus. If the remote keypads are not otherwise sec

Summary of the content on the page No. 15

D7024 Panel Programming 7.6.2.2 Dialing Type Shortcut: 0-PROG, 6-PROG ACC’NTS, 2-PHONE CONTROL This feature determines what format the panel will use for dialing on each phone line. The tone/pulse setting will first try tone dialing, and if that fails, will switch to pulse dialing. Choose Line 1 or Line 2. The display will scroll through the Phone Control options. Press [2] for DIALING TYPE. The following window will display: PHONE CONTRO (__) 1- PULSE ONLY 2- TONE/PULSE 3- T

Summary of the content on the page No. 16

D7024 Panel Programming 7.6.4 Ring Count Shortcut: 0-PROG, 6-PROG ACC’NTS, 4-RING COUNT It is recommended that the number of phone rings before the panel will seize the line to attempt remote programming be left set to “0”. The following window will display: RING COUNT (01-15, 00=DIS) ___ Enter the information and press [#/Cmnd]. The previous window will be displayed. An entry of [0] + [0] will disable ring detection. 7.6.5 Communication Tries Shortcut: 0-PROG, 6-PROG ACC’NT

Summary of the content on the page No. 17

D7024 Panel Programming Notes: D7024 Operation and Installation Guide © 2005 Bosch Security Systems Page 77 41740F

Summary of the content on the page No. 18

D7024 Installation Guide for System 8.0 Installation Guide for System 8.1 D7024-EXP The control panel should be installed in accordance with Local Code for Commercial Fire installations. 8.2 Installation Considerations Failure to install and program the control in accordance with the requirements in this section voids the listing mark of Underwriters Laboratories, Inc. The standby battery capacity is 40 Ah @ 24 VDC. The total nominal current must not exceed 1140 mA in standby nor 4 A wh

Summary of the content on the page No. 19

D7024 Installation Guide for System 8.3.1.6 Communications Programming (if Used for Central Station Service) A communication format compatible with the central station must be selected. Monitoring of both phone lines must be enabled. 8.3.2 Accessory Devices 8.3.2.1 D132B Multi-use Reversing Relay Module The D132B is a multi-purpose, fully configurable, smoke power-reversing module for activating detectors with local annunciation. The D132B will operate both two-wire and four-wire circu

Summary of the content on the page No. 20

D7024 Installation Guide for System 8.3.2.2 D184A Local Energy Kit The D184A is a UL Listed module that connects local energy signaling devices to the D7024 for auxiliary service operation. Refer to the D184A Installation Guide (P/N: 41175) for more information. 8.3.2.3 D185 Reverse Polarity Module The D185 Reverse Polarity Module is a UL Listed module that connects the control panel with either a single set or a pair of leased Telephone Company (Telco) lines in NFPA 72 remote station app


Alternative user manuals
# User manual Category Download
1 Bosch Appliances DS9400 User manual Smoke Alarm 5
2 Bosch Appliances F220-B6 User manual Smoke Alarm 61
3 Bosch Appliances D125B User manual Smoke Alarm 1
4 Bosch Appliances D1257RB User manual Smoke Alarm 0
5 Bosch Appliances EVAX25E User manual Smoke Alarm 11
6 Bosch Appliances D326A User manual Smoke Alarm 0
7 Bosch Appliances DM 1103 BEX User manual Smoke Alarm 0
8 Bosch Appliances FMC-120-DKM User manual Smoke Alarm 4
9 Bosch Appliances FMM462 User manual Smoke Alarm 0
10 Bosch Appliances FMM-7045-D User manual Smoke Alarm 2
11 Bosch Appliances FMR-7036 User manual Smoke Alarm 3
12 Bosch Appliances FMM325A User manual Smoke Alarm 0
13 Bosch Appliances FPA-1000 User manual Smoke Alarm 64
14 Bosch Appliances FMM-7045 User manual Smoke Alarm 1
15 Bosch Appliances LBB 1990 0 User manual Smoke Alarm 2
16 Adobe CS3 User manual Smoke Alarm 1
17 ADT Security Services ADT-LCD40 User manual Smoke Alarm 6
18 ADT Security Services Safewatch Pro 2000 User manual Smoke Alarm 5
19 ADT Security Services SAVS20ADT-1 User manual Smoke Alarm 3
20 ADT Security Services Unimode 9600 User manual Smoke Alarm 7