Oregon Scientific RMR613HGA user manual

User manual for the device Oregon Scientific RMR613HGA

Device: Oregon Scientific RMR613HGA
Category: Clock
Manufacturer: Oregon Scientific
Size: 0.21 MB
Added : 10/25/2013
Number of pages: 17
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Oregon Scientific RMR613HGA. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Oregon Scientific RMR613HGA.

For your convenience

If looking through the Oregon Scientific RMR613HGA user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Oregon Scientific RMR613HGA on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Oregon Scientific RMR613HGA to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Oregon Scientific RMR613HGA User manual - Online PDF
Advertisement
« Page 1 of 17 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Oregon Scientific RMR613HGA but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Oregon Scientific RMR613HGA. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Wireless Thermo-Hygro Clock
Model : RMR613HGA
User Manual
RMR613HGA lab test cover R2 1 1/8/04, 7:02 PM

Summary of the content on the page No. 2

Silence Alarm ....................................................... 10 CONTENTS Temperature and Humidity .................................... 10 Contents ................................................................... 1 Select Temperature Unit ...................................... 10 Introduction .............................................................. 2 Select Sensor Channel ........................................ 10 About Oregon Scientific ........................................

Summary of the content on the page No. 3

INTRODUCTION ABOUT OREGON SCIENTIFIC TM Thank you for selecting the Oregon Scientific Wireless Visit our website (www.oregonscientific.com) to learn Thermo-Hygro Clock (RMR613HGA). This device more about other Oregon Scientific products such as bundles precise time keeping, dual alarm, and digital cameras, hand-held organizers, health and fitness temperature and humidity monitoring features into a gear, and projection clocks. The website also includes single tool you can use from the convenience

Summary of the content on the page No. 4

PRODUCT OVERVIEW FRONT VIEW 1. Clock / Alarm Area: Date, time, dual alarm; and Atomic Clock reception status 2. Temperature Area: Readings; sensor channel number; remote unit reception and battery status 1 3. Humidity / Comfort Zone Area: Readings, comfort zone and battery status. 4. Channel button: switch remote sensor 5. Alarm button: view alarm status; set alarm 2 3 4 5 3 RMR613HGA lab test R2 3 1/17/04, 5:00 PM EN

Summary of the content on the page No. 5

BACK VIEW 1. MEM: view current, maximum, and minimum temperature / humidity readings 2. DOWN: decrease setting / deactivate radio- controlled clock / activate or deactivate alarm 3. UP: increase setting / activate radio-controlled clock / activate or deactivate alarm 4. MODE: change display / settings 3 5. Battery compartment 6. °C / °F switch 1 4 7. RESET hole 2 5, 6, 7 4 RMR613HGA lab test R2 4 1/17/04, 5:00 PM EN

Summary of the content on the page No. 6

REMOTE SENSOR (THGR122NX) 1 1 2 2 3 4 1. LCD display 1. Wall mount hole 2. LED Status indicator 2. RESET 3. Channel number (1 - 3) 4. Battery compartment (Battery compartment cover not shown) 5 RMR613HGA lab test R2 5 1/17/04, 5:00 PM EN

Summary of the content on the page No. 7

CHANGE SETTINGS GETTING STARTED 1. Press and hold MODE for 2 seconds to enter setting BATTERIES mode. Batteries are not supplied with this product. You will need 2. Press UP or DOWN to change settings. to purchase 2 x UM-3 (AA) 1.5V alkaline batteries for 3. Press MODE to confirm. the main unit, and 2 x UM-4 (AAA) 1.5V alkaline batteries for the remote sensor. REMOTE SENSOR (THGR122NX) Insert the batteries before first use, matching the polarity This product is shipped with a THGR122NX Thermo/ a

Summary of the content on the page No. 8

1. Insert the batteries, matching the polarity as shown For best results: in the battery compartment. • Insert the batteries and select the channel and 2. Set the channel. The switch is located in the battery temperature unit before you mount the sensor. compartment. • Place the sensor out of direct sunlight and moisture. SWITCH OPTION • Do not place the sensor more than 30 meters (98 feet) from the main (indoor) unit. Channel Channel 1 - 3. If you are using more than one sensor, select a • Posi

Summary of the content on the page No. 9

ICON DESCRIPTION CLOCK Main unit is searching for This product can track the date and time for up to sensors. 2 locations (Clock with Offset Hour). The US Atomic At least 1 channel has Clock in Boulder, Colorado automatically updates this been found. information unless you disable the feature. The signals Channel 1 is selected are collected by the main unit when it is within 1500 km (number will change (932 miles) of a signal. depending on the sensor you select) Initial reception takes 2 - 10 mi

Summary of the content on the page No. 10

TURN ATOMIC CLOCK ON/OFF SWITCH CLOCK DISPLAY Perform this step if you cannot receive Atomic Clock Press MODE to toggle between Clock with Seconds, signals. Press and hold DOWN for 2 seconds. Then, Clock with Weekday and Calendar, and Clock with Offset manually set the clock following the “Set Clock” Hour display. instructions (below). The signal icon indicates that the Atomic Clock ALARMS feature is ON. No icon means that it is OFF This product has 2 alarms: a Single Alarm and a Weekday Alarm.

Summary of the content on the page No. 11

ACTIVATE ALARM TEMPERATURE AND HUMIDITY Press ALARM to switch to Weekday or Single Alarm view. This product can display the following information from To activate or deactivate the alarm, press UP or DOWN. the remote sensors: VIEW BAROMETER AREA • Alarm deactivated: --:-- • Current, minimum, and maximum temperatures • Alarm activated: Alarm time is shown and relative humidity percentages. • Comfort level W S The bell icons and indicate the alarm display mode selected. Data is collected and

Summary of the content on the page No. 12

ZONE TEMPERATURE HUMIDITY Kinetic- wave >70% Any Icon 20 – 25 ° C 40 – 70% (68 - 77 ° F) Designat- Remote Remote Remote Indoor ed Display Display Display Any <40% Display Display Channel 1 Channel 2 Channel 3 This information is shown in the Humidity Area when the current measurement is displayed. To auto-scan between sensors, press and hold CHANNEL for 2 seconds. Each sensor's data will be displayed for 3 seconds. To end auto-scan, press CHANNEL or MEM. RESET SYSTEM The RESET buttons are locate

Summary of the content on the page No. 13

Do not make any changes or modifications to this SAFETY AND CARE product. Unauthorized changes may void your right to Clean the product with a slightly damp cloth and alcohol- use the product. The technical specification of this free mild detergent. Avoid dropping the product or placing product and contents of this user guide are subject to it in a high-traffic location. change without notice. Images not drawn to scale. TROUBLESHOOTING WARNINGS This product is designed to give you years of servi

Summary of the content on the page No. 14

TEMPERATURE Problem Symptom Remedy Unit °C or °F Remote Cannot locate Check batteries ( 6) Indoor Range -5 °C to 50 °C sensor remote Check location ( 6) (23 °F to 122 °F) sensor Cannot Check sensors. Only Outdoor Range -20 °C to 60 °C change one sensor is working (-4 °F to 140 °F) channel ( 6) Resolution 0.1 °C (0.2 °F) Data does Initiate a manual sensor not match search ( 8) RELATIVE HUMIDITY main unit Range 25% to 95% Resolution 1% REMOTE SENSOR (THGR122NX) SPECIFICATIONS RF frequency

Summary of the content on the page No. 15

Calendar MM/DD; weekday in NOTE: This equipment has been tested and found to 5 languages (E, D, F, I, S) comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are Alarm Weekday and Single designed to provide reasonable protection against Alarm; 2- minute harmful interference in a residential installation. This crescendo equipment generates, uses and can radiate radio frequency energy and, if not installed and used in POWER accordance with the ins

Summary of the content on the page No. 16

DECLARATION OF CONFORMITY is in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: The information below is not to be used as contact for support or sales. Please call our customer service number 1) This device may not cause harmful (listed on our website at www.oregonscientific.com, interference. or on the warranty card for this product) for all inquiries 2) This device must accept any interference instead. received, including interference that may c

Summary of the content on the page No. 17

© 2004 Oregon Scientific. All rights reserved. P/N.: 086-003326-01 RMR613HGA lab test back cover 1 12/29/03, 10:49 PM


Alternative user manuals
# User manual Category Download
1 Oregon Scientific BARM839 User manual Clock 148
2 Oregon Scientific BAR888RA User manual Clock 82
3 Oregon Scientific DP200 User manual Clock 96
4 Oregon Scientific BAR332ESA User manual Clock 24
5 Oregon Scientific BAR623PA User manual Clock 138
6 Oregon Scientific EB833 User manual Clock 209
7 Oregon Scientific BA812E User manual Clock 731
8 Oregon Scientific BAR339P User manual Clock 600
9 Oregon Scientific BAR332ESU User manual Clock 17
10 Oregon Scientific BAR332ES User manual Clock 326
11 Oregon Scientific BARM839A User manual Clock 35
12 Oregon Scientific IWA-80055 User manual Clock 111
13 Oregon Scientific JMR868A User manual Clock 9
14 Oregon Scientific PE326FM Pedometer with Radio User manual Clock 74
15 Oregon Scientific DP200A User manual Clock 12
16 Philips 170P6 User manual Clock 1
17 Acu-Rite 13239CCD User manual Clock 15
18 Philips AJ290/12 User manual Clock 1
19 American Innovative, TMT081-US User manual Clock 6
20 Philips Professional 202P4 User manual Clock 2