Omega LDP-124 user manual

User manual for the device Omega LDP-124

Device: Omega LDP-124
Category: Clock
Manufacturer: Omega
Size: 0.27 MB
Added : 10/30/2013
Number of pages: 18
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Omega LDP-124. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Omega LDP-124.

For your convenience

If looking through the Omega LDP-124 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Omega LDP-124 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Omega LDP-124 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Omega LDP-124 User manual - Online PDF
Advertisement
« Page 1 of 18 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Omega LDP-124 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Omega LDP-124. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

User's Guide
http://www.omega.com
e-mail: info
@omega.com
LDP-124, LDP-126, LDP-144 AND LDP-146
OPERATOR´S MANUAL FOR CLOCK MODELS

Summary of the content on the page No. 2

OMEGAnet On-Line Service Internet e-mail http://www.omega.com info@omega.com Servicing North America: USA : One Omega drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 Tel : (203) 359-1660 Fax : (203) 359 7700 e-mail : info@omega.com Canada : 976 Bergar Laval (Quebec) H7L 5A1 Tel : (514) 856-6928 Fax : (514) 856-6886 e-mail : info@omega.com For immediate technical or application assistance: SM USA and Canada : Sales Service : 1-800-826-6342 / 1-800-TC-OMEGA SM Customer Service : 1-800-

Summary of the content on the page No. 3

CONTENTS DESCRIPTION SECTION PAGE =========================================================================== IMPORTANT SAFETY CONSIDERATIONS 13 UNPACKING AND INSPECTION 24 MAIN FEATURES 34 MODELS 45 MODEL LDP-1XX-C0, DISPLAY TIME USING THE FORMAT MM : SS 4.1 5 MODEL LDP-1XX-C1, DISPLAY TIME USING THE FORMAT HH : MM 4.2 5 MODEL LDP-1XX-C2, DISPLAY TIME USING THE FORMAT HH : MM : SS 4.3 5 GENERAL SPECIFICATIONS 56 FRONT VIEW, DESCRIPTION 67 REAR VIEW, DESCRIPTION 77 WIRING 88 POWER SUPPLY, RECOMM

Summary of the content on the page No. 4

1.- IMPORTANT SAFETY CONSIDERATIONS INSTALLATION PRECAUTIONS.- SAFETY CONSIDERATIONS The installation and the future use of this unit PRESCRIPTIONS.- must be done by suit- able qualified person- Before starting any operation of adjustment, replacement, nel. The unit has not AC maintenance or repair, the unit must be disconnected from any kind (mains) switch, it will be of power supply. in operation as soon as Keep the unit clean , to assure good functioning and performance. power is conne

Summary of the content on the page No. 5

2.- UNPACKING AND INSPECTION It is advisable to do a detailed reading of this Manual before mounting the instrument. This Operator's Manual contains all the technical specifications : electricals as well as mechanics, both necessary to do a correct installation and also a good use of the instrument. At the same time the user will acquire the knowledge needed to obtain the best performances of the product. Check that inside the present cardboard box, there are the following : 1 Instrument Mode

Summary of the content on the page No. 6

The common features for all series are the following: MECHANICAL.- Housed in a rugged extruded aluminium profile housing for panel mounting or free standing. Finished in anodized black colour. The frontal lens is mounted with a special rubber profile which provides the front part of the unit with an IP-65 protection. CONTROL SIGNALS .- Three inputs, sharing one common return. The operating mode depends on interlinking of the three control lines CONNECTIONS.- For output alarm are made using one

Summary of the content on the page No. 7

5.- GENERAL SPECIFICATIONS DISPLAY Type . . . . . . . . . . . . . . . . . 4 or 6 digits, 7 segments, red or green LED. OUTPUTS Height digit . . . . . . . . . . . . 57 (2.3") or 100 mm. (4") Range máx. . . . . . . . . . . . . 99 : 59 or 99 :59 : 59 SERIAL OUTPUT . . . . . . . Output intended for transmission to the Brightness . . . . . . . . . . . . . Set by switch for 25%, 50%, 75% remote display fitted with a clock or 100% (normal). display as a slave clock display. Signal . . . . . . . . . . .

Summary of the content on the page No. 8

6.- FRONT VIEW, DESCRIPTION colon Models LDP-124-C0 & C1 LDP-144-C0 & C1 Display minutes for model C0 Display seconds for model C0 Display hours for model C1 Display minutes for model C1 Models LDP-126-C2 LDP-146-C2 Display hours for model C2 Display minutes for model C2 Display seconds for model C2 7.- REAR VIEW, DESCRIPTION for all series Attaching screws Connector Sub-D 15 pins for Control Lines and voltage excitation output 4 ways plug-in screw connector for alarm Power Supply output Vac + E

Summary of the content on the page No. 9

8.- WIRING 8.1.- POWER SUPPLY, RECOMMENDED WIRING POWER SUPPLY 115 Vac (230 Vac Optional). Main switch FUSE and spare fuse. 8.2.- PROTECTION FUSES Power Fuse The unit has a protection fuse located on the power supply socket. Supply value If this fuse must be replaced or changed because the power supply is changed, use the time-lag fuse according to IEC 127/2 with the 230 Vac 0.2 A values indicated on the table. 115 Vac 0.4 A TABLE 4 8.3.- CONTROL LINES, ALARM AND SERIAL OUTPUT Control lines conn

Summary of the content on the page No. 10

8.5.- EXCITATION VOLTAGE FOR SENSORS The unit supplies the Excitation Voltage for sensors, through control lines connector. If the current required for the sensors installed is more than 100 mA then do not use this terminal. Install other external power supply. See paragraph 5 for technical specifications 9.- POWER-UP AND OPERATION 9.1.- REAL TIME CLOCK At power-up, the unit displays the message MAStEr for 6 decade version or MASt for 4 decade version and will start to operate. If a failure occ

Summary of the content on the page No. 11

9.2.2.- CONNECTION EXAMPLES Different interlinking of the three control lines will produce different operating modes: Stop Stop Push B = start A A Push A = stop Start Start B Push C = reset C Reset Reset note A may close while B Close contact A = reset and run is shut Open contact A = stop GND GND B may open while A is shut Stop With contact B opened A close contact A = run Start Stop B open contact A = stop B Reset Start Push A = reset and start A Push B = stop push contact B = reset Reset GND

Summary of the content on the page No. 12

10.2.1- CONTROL BOARD POSITION Control board position for instruments Control board position for instruments series LDP-2X-CX series LDP-4X-CX 10.2.2- DIP SWITCH AND JUMPERS LOCATION JP1 JP2 JP3 JP4 ON OFF

Summary of the content on the page No. 13

10.2.4- JUMPERS CONFIGURATION Function Close Jumper 220 Ω terminator resistor for the RS422 JP1 (By default opened) switch debounce of 5 Hz for the STOP line JP2* (By default closed) switch debounce of 5 Hz for the START line JP3* (By default closed) switch debounce of 5 Hz for the RESET line JP4* (By default closed) Jumper Application A Jumper position B JP5 for STOP line 1 KΩ pull-up * 1 KΩ pull-down JP6 for START line falling edge/low level active*

Summary of the content on the page No. 14

11.- INSTALLATION 1.- Prepare a panel cut-out with the dimensions indicated on paragraph 12. 2.- Slide the instrument (1) into the cut-out. 3.- Slide the two fixation pieces (3) with T shape by both lateral sides of the instrument, such as it is shown on the drawing below. 4.- Turn the screw bolt until it is pressed firmly against the panel (4) and the instrument (1) remains totally fixed. 5.- The front part of the instrument has the necessary elements to provide an IP 65 protection. If the pane

Summary of the content on the page No. 15

APPENDIX 1: MODEL LDP-1XX-CX AS SLAVE REPEATER. FUNCTIONAL DESCRIPTION: Special configuration of Models LDP-1XX-CX for serial RS-422 repeater, to be used as slaves. The Serial port connection which is the only that keeps in operation, it is used to enter the data coming from the Master. The rest of functions and connections of these Models, remain disabled. CONFIGURATION OF A SLAVE MODEL, STARTING FROM A MASTER MODEL LDP-1XX-CX: - Remove the integrated circuit "IC4" placed on the PCB "98/04" and

Summary of the content on the page No. 16

APPENDIX 2: TIME-NET CONFIGURATION AND CONNECTIONS. It is advisable to make the TIME-NET connections as follows: Transmitter MASTER Unit n (maximum 32 units) 1 2 3 4 Receiver SLAVE SLAVE SLAVE SLAVE SLAVE Units Connect RS-422 (JP1) line termination. Don’t connect RS-422 (JP1) line termination. Note Shielded twisted-pair cable, must be used for connections. SLAVE MASTER Don’t connect the cable shield to the receiver units (slaves). 1 1 9 9 6 6 To other sla

Summary of the content on the page No. 17

WARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product. If the unit malfunction, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department wi

Summary of the content on the page No. 18

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA...Of Course! TEMPERATURE Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies Wire: Thermocouple, RTD & Thermistor Calibrators & Ice Point References Recorders, Controllers & Process Monitors Infrared Pyrometers PRESSURE, STRAIN AND FORCE Transducers & Strain Gauges Load Cells & Pressure Gauges Displacement Transducers Instrumentation & Accessories FLOW/LEVEL Rotameters, Gas Mass Flowmeters &


Alternative user manuals
# User manual Category Download
1 Omega LDP-144 User manual Clock 2
2 Omega LDP-126 User manual Clock 1
3 Omega LDP-146 User manual Clock 0
4 Omega Products, IncOM-EL-ENVIROPAD-TC User manual Clock 7
5 Philips 170P6 User manual Clock 1
6 Acu-Rite 13239CCD User manual Clock 15
7 Philips AJ290/12 User manual Clock 1
8 American Innovative, TMT081-US User manual Clock 6
9 Philips Professional 202P4 User manual Clock 2
10 Brookstone 643403 User manual Clock 81
11 Acroprint ATR120 User manual Clock 18
12 Casio User manual Clock 8
13 Acu-Rite DeIux wirelss weather station and atomic User manual Clock 7
14 Casio ID-12 User manual Clock 0
15 Philips AK 703 User manual Clock 1