Summary of the content on the page No. 4
System Overview Features and Benefits System Capability NEW Touch Screen Interface The Agilent 16702B mainframe supports a large, 12.1 inch LCD touch screen and redesigned front panel controls for an easy-to-operate, self-contained unit requiring minimal bench space and offering simple portability. NEW Multiframe Configuration By connecting up to eight mainframes and expanders you can simultaneously view time-correlated traces for all buses in a large channel count, multibus system. NEW Enhan
Summary of the content on the page No. 5
System Overview Features and Benefits Data Transfer, Documentation, and Remote Programming ® Direct Link to Microsoft Excel via • Automatically move your data from the logic analyzer into Microsoft Excel with just a click of the mouse. Agilent IntuiLink (See page 12) • Use Microsoft Excel’s powerful functions to post-process captured trace data to get the insight you need. Transfer Data for Offline Analysis - • Fast binary (compressed binary) from the FileOut tool provides highest performance t
Summary of the content on the page No. 6
System Overview Selecting the Right System Selecting a system for your application Select a mainframe (page 7) Choose a system based on your needs: • Self-contained unit or a unit with external mouse, keyboard, and monitor • Expander frame for large channel count requirements Determine your probing requirements (page 13) • Are you analyzing a microprocessor? • Do you need to probe a specific package type? Select the measurement modules to meet your application needs • State/Timing Logic Analyze
Summary of the content on the page No. 7
Mainframes Display 12.1" LCD display with touch screen on Select a modifiable variable by touching Dedicated hot keys give instant access to the 16702B makes it easy to view a large it, then turn the knob to quickly step the most frequently used menus, displays, number of waveforms or states. through values for the variable. and on-line help. Dedicated knobs for horizontal and vertical "Touch Off" button disables the touch Dedicated knobs for global markers help scaling and scrolling. Adjust the
Summary of the content on the page No. 8
Mainframes Back Panel Connection for optional monitor. Parallel printer port SCSI-II connection for an (Up to 1600x1200 video external 18 GByte data drive or 10/100BaseT LAN - autosensing resolution with option 003) external removable hard drive Five slots for measurement modules Option slot for an emulation module or Expander frame connection provides an Built-in 40x CD-ROM drive makes it easy for a multiframe module. Multiframe additional five slots for measurement to install or update sys
Summary of the content on the page No. 9
Mainframes System Screens Figure 2.3. Icons in the power-up screen give you quick access to common tasks. System Admin Setup Assistant Demo Center allows you to quick- is a guided menu provides simple ly set up the instru- system that helps demos of the most ment on your net- you configure the commonly used work, configure logic analysis sys- features. print servers, set up tem for your target user accounts for microprocessor or security or install bus. Online infor- software updates. mation g
Summary of the content on the page No. 10
Mainframes System Screens See the Big Picture of Your Prototype System's Behavior A large external display (option 001) with multiple, resizable windows allows you to see at a glance more of your target system's operation. A built-in, flat-panel display in the 16702B fits in environments with limited space. Color lets you highlight critical information so you can find it quickly. Use one system to examine target operation from different perspec- tives. Multiple time-correlated views of data le
Summary of the content on the page No. 11
Mainframes System Screens Expanding Possibilities with Network Connectivity Web-enabled instrumentation gives you the freedom to access the system—anywhere, anytime. Have you ever needed to check on a measurement's status while you were in a remote location? Now you can. With a Web Enabled Logic Analysis System You Can... ...access Agilent's Web site for the latest ...install Agilent IntuiLink to seamlessly online manuals and technical information transfer data from the system to a PC ...acce
Summary of the content on the page No. 12
Mainframes IntuiLink Agilent IntuiLink Moves Your Data Automatically into ® Microsoft Excel for Advanced Offline Analysis IntuiLink is shipped with each logic analysis system and can be down- loaded to your PC from the system’s own web page. Use the Agilent IntuiLink tool bar to connect to a logic analysis system. Select from the available labels and specify the destination cell location in Microsoft Excel. Use Microsoft Excel's powerful functions to post-process captured trace data for the ins
Summary of the content on the page No. 13
Probing Solutions Criteria for Selection Why is Probing Important? Your debugging tools perform three important tasks: probing your target system, acquiring data, and analyzing data. Data acquisition and analysis tools are only as effective as the physical interface to your target system. Use the following criteria to see how your probing measures up. How to Determine Your Requirements To determine what probing method is best to use you need to take the following into consideration: • The nu
Summary of the content on the page No. 14
Probing Solutions Technologies Choose the Optimum Probing Strategy for Your Application NEW Figure 3.3. The E5382A single-ended flying lead Connecting to individual test probe set provides connections for 17 channels of the 16760A logic analyzer. points with flying leads Figure 3.4. Surface mount IC clip. 5090-4356 (20 clips). Figure 3.2. Figure 3.5. 0.5 mm IC clip. 10467-68701 (4 clips). Advantages Limitations Most flexible method. Can be time-consuming to connect a large Flying-lead probes
Summary of the content on the page No. 15
Probing Solutions Technologies Designing connectors into the target system Figure 3.8. Advantages Limitations Very reliable connections. Requires advance planning in the design stage. Saves time in making multiple connections. Requires some dedicated board space. Moderate incremental cost. High-density probing solutions Model Description Requires kit of 5 connectors Usable with number and 5 shrouds logic analyzers E5385A 100-pin probe with built-in isolation networks for the logic analyzer 167
Summary of the content on the page No. 16
Probing Solutions Technologies Using a processor- or bus-specific analysis probe Figure 3.10. Advantages Limitations Refer to “Processor and Bus Support for Agilent Technologies Logic Easiest and fastest connection to supported Moderate to significant incremental cost. Analyzers,” publication number processors and buses. Only useable for the specific processor or bus. 5966-4365E, for specific solutions. May require moderate clearance around processor or bus. 16
Summary of the content on the page No. 17
Data Acquisition and Stimulus State/Timing Modules performance, cost, and the amount of Selecting the Correct Modules data you will be able to capture. The to Meet Your Needs following table explains these factors Selecting the proper logic analyzer in greater detail. modules for your needs requires a series of choices concerning Considerations for Choosing Modules Microprocessor/ Will you be using an analysis probe for a particular processor or bus? If so, a good starting point is the documen
Summary of the content on the page No. 18
Data Acquisition and Stimulus State/Timing Modules Considerations for Choosing Modules (continued) Channel Count Determine the number of signals you want to analyze on your system under test. You will need this number of channels in your logic analyzer. Even if you have enough channels to view all the signals in your system today, you should consider logic analysis systems that allow you to add more channels for your future application needs. Memory Depth • Complex architectures and bus protoc
Summary of the content on the page No. 19
Data Acquisition and Stimulus State/Timing Modules Multichannel Eye scan allows you to make eye diagram measurements, quickly and easily, Key Features of Agilent’s Eye measurements on hundreds of channels simultaneously (16760A only) State/Timing Modules Triggering for the VisiTrigger combines powerful trigger functionality with a user interface • Memory depth up to 128M most elusive that is easy to understand and use. Capturing complex sequences of samples at a price to meet your problems e
Summary of the content on the page No. 20
Data Acquisition and Stimulus State/Timing Modules Improve Your Productivity with an Intuitive User Interface Agilent Technologies has made the user interface easy to understand and use. Now you can spend more time making measurements and less time setting up the logic analyzer. Timing Zoom provides 2 GSa/s timing analysis simultaneous with state or conventional timing analysis on all Format allows you to channels. Sampling rate and position group signals into buses. relative to trigger are adju
Summary of the content on the page No. 1
16700 Series
Logic Analysis System
Product Overview
Debugging today's digital systems The Agilent Technologies
is tougher than ever. Increased 16700 Series logic analysis systems
product requirements, complex provide the simplicity and power you
software, and innovative hardware need to conquer complex systems
technologies make it difficult to by combining state/timing analysis,
meet your time-to-market goals. oscilloscopes, pattern generators,
post-processing tool sets, and
emulation in one i
Summary of the content on the page No. 2
Table of Contents System Overview Modular Design page 3 Features and Benefits page 4 Selecting the Right System page 6 Mainframes Display page 7 Back Panel page 8 System Screens page 9 IntuiLink page 12 Probing Solutions Criteria for Selection page 13 Technologies page 14 Data Acquisition and Stimulus State/Timing Modules page 17 Oscilloscope Modules page 30 Pattern Generation Modules page 33 Emulation Modules page 37 Post-Processing and Analysis Tool Sets Software Tool Sets page 39 Source Corre
Summary of the content on the page No. 3
System Overview Modular Design Module Choices User Benefits Modular Design Protects Your Long-Term Investment State/Timing Agilent offers a wide variety of state/timing modules for a range Modularity is the key to the Agilent of applications, from high-speed glitch capture to multi-channel 16700 Series logic analysis systems' bus analysis. long term value. You purchase only High-Speed Timing Precisely characterize setup/hold times over a wide channel the capability you need now, then count. C