Summary of the content on the page No. 1
ULIN_016357_30096.fm Page 1 Wednesday, February 7, 2007 12:46 PM
Use and Care Guide
Clear Ice Maker Model:
CLR2160
®
Ice Maker/Refrigerator
Clear Combo
Model:
CLRCO2175
CLR2160 CLRCO2175
Summary of the content on the page No. 2
1 Introduction Congratulations on your purchase of a U-Line refrigeration product. A pioneer in the field for more than 40 years, U-Line Corporation is the world’s number one manufacturer of built-in, under-counter, specialty refrigeration and ice making products. U-Line dedicates 100% of its research and development to these products. The result: U-Line technology consistently leads the market with innovation, design, depth of product line and performance. U-Line products are making life mor
Summary of the content on the page No. 3
2 Table of Contents Introduction ...............................................................................................................................2 Warranty Registration .......................................................................................................2 Please Record Your Model Information ...........................................................................2 Table of Contents ...............................................................................
Summary of the content on the page No. 4
This page intentionally left blank 4 CLR2160, CLRCO2175
Summary of the content on the page No. 5
WARNING 3 Safety Precautions SHOCK HAZARD - Electrical Grounding Required. IMPOR IMPORT TAN ANT T � Never attempt to repair or perform maintenance on the unit until the electricity PLEASE READ all instructions completely before has been disconnected. attempting to install, operate, or service your unit. � Never remove the round grounding prong from � Proper installation procedures must be followed the plug and never use a two-prong grounding if this unit is being initially installed, or is
Summary of the content on the page No. 6
Exclusive Features of Échelon 4 Product Features � An easy, self-cleaning process for the clear ice maker eliminates complicated procedures. Échelon Model CLR2160 Clear Ice � Black and white models feature a slightly contoured, Maker, Model CLRCO2175 Clear Ice across the top, integrated door handle design that permits the door to be easily reversed. The door comes Maker/Refrigerator standard with a factory-installed flush panel. These CLR2160 models can accommodate a 1/4 in. (0.64 cm) th
Summary of the content on the page No. 7
Other Site Requirements 5 Operation Power Supply The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A circuit (normal household current). See Electrical Specifications on Page 23. Water Supply The unit requires a 1/4-inch OD water supply line and a shut-off valve. For more information see Page 22. ULIN_0080_A Drain Figure 2 The unit’s generous 7-inch drain connection height extends the distance the unit can be located from a IMPOR IMPORT TAN ANT T gravity drain. For more informati
Summary of the content on the page No. 8
Temperature Control Interior Lighting The interior of Model CLR2160 is not illuminated. The Checking Product Temperature refrigerator section of Model CLRCO2175 is illuminated whenever the door is opened. The LIGHT icon (Figure 3, 5) on the control panel is used to control an additional Model CLRCO2175 lighting function. The blackout/Sabbath mode (not Star K certified) will turn the interior light and display (Figure 3, 3) off. To access the blackout/Sabbath mode (not Star K certified): 1
Summary of the content on the page No. 9
Temperature Display Normal Operating Sounds To display the Model CLRCO2175 interior temperature: All models incorporate rigid foam insulated cabinets to provide high thermal efficiency and maximum sound 1. Touch and hold the WARMER icon (Figure 5, 2) for reduction for its internal working components. In spite of approximately five seconds and release when the °F this technology, your model may make sounds that are symbol in the display (Figure 5, 3) begins to flash. unfamiliar. 2. The dis
Summary of the content on the page No. 10
Storage, Vacation, Moving Product Disposal If the unit will not be used for an extended period, or If the unit is being removed from service for disposal, otherwise stored, follow these steps completely: check and obey all Federal, State and/or Local regulations regarding the disposal and recycling of refrigeration appliances, and follow these steps completely: WARNING 1. Disconnect power to the unit and unplug the power Electrical Shock Hazard. Disconnect power before cord from its outlet.
Summary of the content on the page No. 11
Maintenance 6 Cleaning and Maintenance Proper maintenance of your U-Line product will ensure efficiency, top performance and long life. The General Cleaning maintenance intervals listed are based on normal conditions. You may want to shorten the intervals if you Exterior Cleaning (As Required) have pets or other special considerations. Black and White Models: Defrosting � Surfaces may be cleaned with a mild detergent and warm water solution. Do not use solvent-based or Automatic (Cycle) De
Summary of the content on the page No. 12
To defrost: 4. Clean the condenser coil (Figure 8, 2) using a soft brush with a “combing” action or vacuum cleaner. Do 1. Turn unit off. not touch the condenser coil. 2. Remove all products from the interior and prop the 5. Position the grille to align the mounting screws with door in an open position (2 in. (5 cm) minimum). the holes in the cabinet. 3. Allow the frost to completely melt naturally. Clean the 6. Secure, but do not over-tighten both grille screws. interior and all removed com
Summary of the content on the page No. 13
it from the drain hole. The water in the reservoir will 12 3 4 5 flow down the drain. 5. Replace the overflow tube after all of the water has drained from the reservoir. 6. Start the cleaning cycle as follows: ULIN_0058_A a. Touch and hold the ON/OFF button (Figure 9, 1). Figure 9 b. Touch and release the LIGHT button (Figure 9, 4) three times, then release the ON/OFF button 1. Turn the ice maker off (allowing any ice to melt off of (Figure 9, 1). the evaporator) as follows: c. The display
Summary of the content on the page No. 14
b. Touch and release the DOWN ARROW (Figure 13, 2) button three times, then release the UP 2 ARROW button (Figure 13, 1). 3 c. The display (Figure 13, 3) will switch to “0” to confirm the thickness adjustment mode has been selected. 2. The factory setting is “0,” and the total range of adjustment is -5 to +5. Use the UP ARROW button to raise the setting and thicken the ice bridge, or the DOWN ARROW button to lower the setting to thin the ice bridge. IMPOR IMPORT TAN ANT T 1 ULIN_0061_A I
Summary of the content on the page No. 15
Door Alignment Check and Adjustment IMPOR IMPORT TAN ANT T When properly aligned: � The door will not be flush with the top of the cabinet. The top edge of the door will be 1/8 in. (3.175 mm) below the cabinet top. � The door gasket will be firmly in contact with the perimeter of the cabinet and not pinched on the hinge side of the door. ULIN_0047_A The following procedure will correct for up to 1/4 in. Figure 15 misalignment: A unit that is not level can cause a reduction in ice rate, une
Summary of the content on the page No. 16
Door Reversal 1 23 ULIN_0201_A Figure 20 3. Turn the door upside down and inspect the hinge plate mounting holes. � Your plate has slotted mounting holes (Figure 20, 1). Loosen but do not remove the two hinge plate screws. 4. If door edge opposite the hinges needs to move up, move plate toward outside of door (Figure 20, 2). If door edge needs to move down, move plate toward inside of door (Figure 20, 3). Repeat until top edge of ULIN_0015_A door is parallel with top of cabinet and tight
Summary of the content on the page No. 17
5. Remove the two door closer inserts (Figure 26, 1) from the existing bottom hinge and install as shown on the 1 new bottom hinge (Figure 25, 1). 6. Remove existing bottom hinge (three screws) and remount on opposite side TOP. Remove hinge screw pin. 7. Remove the plastic hole plug from the top of the door to allow the pivot pin to be inserted in the new ULIN_0002_A location. Install the plug into the vacated hole on the opposite side. Figure 24 2. Remove plastic screw plugs (three each,
Summary of the content on the page No. 18
Insert the shelves as follows: Door Shelf Removal/Insertion 1. To move to a different position in the unit, insert shelf at an angle, approximately 15-20°, over the rib in the side of the unit where you want to place the shelf. The 1 shelf must be started into the unit at an angle to clear the door. 2. Continue to slide the shelf into the unit at an angle until it clears the door. 3. Lower the shelf and push it in completely. 2 ULIN_0039_A Figure 28 To remove the door shelf: 1. Grasp shelf
Summary of the content on the page No. 19
Light Bulb Replacement 7 Prepare Plumbing CLRCO2175 To replace the light bulb in your U-Line unit: CAUTION Plumbing installation must observe all state and local codes. All water and drain connections MUST 2 BE made by a licensed/qualified plumbing 1 contractor. Failure to follow recommendations and instructions may result in damage and/or harm. ULIN_0001_A Drain Connection Figure 30 IMPOR IMPORT TAN ANT T 1. Grasp the edges of the light housing lens Drain can NOT be located directly below
Summary of the content on the page No. 20
Gravity Drain Disposal Assembly Air Gap (Optional Hook-Up) Waste Shut-Off Waste Valve Cold Water Hot Cold Water Hot Water Water Shut-Off Valve Waste Figure 34 Figure 32 If using a Gravity Drain: Spigot Assembly 1. Attach the 5/8-inch ID drain connection on the back of Air Gap the unit to a 5/8-inch OD rigid tube, using a worm (Optional Hook-Up) clamp. 2. Attach the other end of the rigid tube to your 5/8-inch ID drain line with a worm clamp. 3. Insulate the drain line, if necessary to prevent