Vulcan-Hart SPER1 SPER2 ML-52919 user manual

User manual for the device Vulcan-Hart SPER1 SPER2 ML-52919

Device: Vulcan-Hart SPER1 SPER2 ML-52919
Category: Fryer
Manufacturer: Vulcan-Hart
Size: 0.35 MB
Added : 6/11/2014
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Vulcan-Hart SPER1 SPER2 ML-52919. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Vulcan-Hart SPER1 SPER2 ML-52919.

For your convenience

If looking through the Vulcan-Hart SPER1 SPER2 ML-52919 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Vulcan-Hart SPER1 SPER2 ML-52919 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Vulcan-Hart SPER1 SPER2 ML-52919 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Vulcan-Hart SPER1 SPER2 ML-52919 User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Vulcan-Hart SPER1 SPER2 ML-52919 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Vulcan-Hart SPER1 SPER2 ML-52919. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION &
OPERATION MANUAL
SPER1 & SPER2 ELECTRIC FRYERS
MODEL
SPER1 ML-52918
SPER2 ML-52919
SPER0 Frymate ML-52920
SPER1 & 2
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL. (502) 778-2791
FORM 30729 Rev. A (1-95)

Summary of the content on the page No. 2

Installation, Operation and Care of MODEL SPER1 & SPER2 ELECTRIC FRYERS PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE GENERAL Your Vulcan fryer is produced with quality workmanship and material. Proper installation, usage and maintenance of your fryer will result in many years of satisfactory performance. Vulcan-Hart Company suggests that you thoroughly read this entire manual and carefully follow all of the instructions provided. INSTALLATION Before installing, verify that the electrical servic

Summary of the content on the page No. 3

INSTALLATION CODES AND STANDARDS Your Vulcan fryer must be installed in accordance with: 1. State and local codes. 2. The National Electrical Code, ANSI/NFPA No. 70 (latest edition). Copies may be obtained from The National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. 3. NFPA Standard #96. LEVELING Place a carpenter's level on top of the fryer and level the fryer front-to-back and side-to-side by turning the adjustable legs. If your fryer is equipped with the optional non-

Summary of the content on the page No. 4

OPERATION WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. BEFORE FIRST USE Cleaning Clean the fryer thoroughly, following the procedures described in this manual under CLEANING — WEEKLY OR AS REQUIRED. Clean all fryer accessories. Rinse all parts thoroughly after cleaning and wipe dry. Seasoning Light seasoning of the backsplash area is required to avoid possible surface corrosion. With a soft, lint-free cloth, apply a thin layer of cook

Summary of the content on the page No. 5

POWER SWITCH — Controls electric supply to fryer (Optional - hood ventilator to interlock.) POWER ON LIGHT — Indicates when electric supply is on. TEMPERATURE CONTROLLER — Maintains frying temperature by controlling power supply. HEATING LIGHT — When on, indicates temperature control is calling for power to the elements. FRY/MELT SWITCH — Controls melting or frying cycle. Use MELT cycle position to melt solid shortening. When melted, turn switch to FRY position, with thermostat set at desired

Summary of the content on the page No. 6

Split Vat 1. Remove crumb screens. 2. Divide a 50-pound block of shortening into two equal halves (approximately 25 pounds each). 3. Place each half of the shortening directly on the heating elements in each well of the fry tank and slide back. 4. Place crumb screens on top of shortening in tank. Single Vat 1. Remove crumb screen. 2. Place 50-pound block of shortening directly on the heating elements in the tank and slide back. 3. Place crumb screen on top of shortening. Melt Cycle 1. Set temper

Summary of the content on the page No. 7

1. Allow shortening to cool before draining or filling. 2. Consult the operating instructions supplied by the manufacturer of your filtering system before filtering the shortening. 3. Firmly screw the fryer drain nipple (supplied) into the fryer drain valve (Fig. 2). Position your filtering container under the drain nipple mouth before opening the drain valve. 4. Completely open the drain valve. Let the shortening drain into the filter container. If the drain valve becomes clogged with food p

Summary of the content on the page No. 8

SHORTENING MAINTENANCE Shortening life may be extended by following these important procedures. Do not salt foods over the fryer. Use good quality shortening. Filter shortening daily at a minimum. Keep equipment and surroundings clean. Set thermostats correctly. Do not use excessively high temperatures. Remove excess moisture and particles from food products before placing in fryer. Dip out several cups of shortening from fry tank every day and add fresh shortening to replace it. CLEANING DAILY

Summary of the content on the page No. 9

7. Turn power switch OFF at termination of burn-off cycle. 8. Heating elements will heat up in excess of 600°F glowing red. If any do not glow, call a Vulcan- authorized service agency. Some smoking, crackling sound and puffs of flame will occur. This is normal. If excessive flaming occurs, turn power switch OFF and extinguish immediately to prevent damage to elements and thermostat bulbs. 9. Allow elements to cool and press reset button on rear of element head (Fig. 3). 10. Brush resi

Summary of the content on the page No. 10

6. Drain solution and discard. Close drain valve and fill tank half full with water. 7. Scrub entire inside of tank with a stiff bristle nylon brush. 8. Drain solution and rinse tank thoroughly with clean water. 9. Close drain valve and refill tank with clean hot (minimum 140°F) water. Add 1 cup of vinegar to neutralize alkaline left by the cleaner. Turn power switch ON and boil again for 15 minutes. 10. Turn power switch OFF, allow solution to cool, drain, then rinse thoroughly with

Summary of the content on the page No. 11

MAINTENANCE WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. WARNING: DISCONNECT ELECTRICAL POWER SUPPLY BEFORE PERFORMING ANY MAINTENANCE. CALIBRATION PROCEDURES 1. Monitor shortening temperature 1" below the surface with an accurate temperature measuring device. 2. Turn power switch ON, and when coming up from lower temperature, set temperature control knob to frying temperature. 3. Allow fryer to reach temperature (when heating light go

Summary of the content on the page No. 12

FORM 30729 Rev. A (1-95) PRINTED IN US.A. — 12 —


Alternative user manuals
# User manual Category Download
1 Vulcan-Hart 1GR45C ML-136414 User manual Fryer 3
2 Vulcan-Hart 1GR45CF ML-136791 User manual Fryer 1
3 Vulcan-Hart 1GR45M ML-136408 User manual Fryer 1
4 Vulcan-Hart 1GR65C ML-136415 User manual Fryer 2
5 Vulcan-Hart 1GR45MF ML-136785 User manual Fryer 0
6 Vulcan-Hart 1GR45D ML-136411 User manual Fryer 7
7 Vulcan-Hart 1GR45M User manual Fryer 2
8 Vulcan-Hart 1GR65CF ML-136792 User manual Fryer 0
9 Vulcan-Hart 1GR45DF ML-136778 User manual Fryer 0
10 Vulcan-Hart 1GR65M User manual Fryer 0
11 Vulcan-Hart 1GR65MF ML-136786 User manual Fryer 0
12 Vulcan-Hart 1GR65D ML-136412 User manual Fryer 9
13 Vulcan-Hart 1GR65DF ML-136789 User manual Fryer 1
14 Vulcan-Hart 1GR65M ML-136409 User manual Fryer 1
15 Vulcan-Hart 1GR85M ML-136410 User manual Fryer 0
16 Alto-Shaam Inc.ASF-75E User manual Fryer 1
17 Alto-Shaam FRY TECH ASF-75E User manual Fryer 1
18 Alto-Shaam Inc.Gas User manual Fryer 1
19 Alto-Shaam FRY TECH ASF-60E User manual Fryer 5
20 Alto-Shaam FRYTECH ASF-60G User manual Fryer 6