Vulcan-Hart ECONOFRY EF4 ML-114943 user manual

User manual for the device Vulcan-Hart ECONOFRY EF4 ML-114943

Device: Vulcan-Hart ECONOFRY EF4 ML-114943
Category: Fryer
Manufacturer: Vulcan-Hart
Size: 0.25 MB
Added : 9/2/2014
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Vulcan-Hart ECONOFRY EF4 ML-114943. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Vulcan-Hart ECONOFRY EF4 ML-114943.

For your convenience

If looking through the Vulcan-Hart ECONOFRY EF4 ML-114943 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Vulcan-Hart ECONOFRY EF4 ML-114943 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Vulcan-Hart ECONOFRY EF4 ML-114943 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Vulcan-Hart ECONOFRY EF4 ML-114943 User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Vulcan-Hart ECONOFRY EF4 ML-114943 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Vulcan-Hart ECONOFRY EF4 ML-114943. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALLATION &
OPERATION MANUAL
MODELS EF3, EF4, & EF5 ECONOFRY
GAS FRYERS
MODELS
EF3 ML-52099
EF4 ML-114943
EF5 ML-114944
Model EF3
VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL. (502)778-2791
FORM 31052 (1-98)

Summary of the content on the page No. 2

IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OBTAINED FROM THE LOCAL GAS SUPPLIER. IMPORTANT IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GA

Summary of the content on the page No. 3

Installation, Operation and Care of MODELS EF3, EF4 & EF5 ECONOFRY GAS FRYERS KEEP THESE INSTRUCTIONS FOR FUTURE USE GENERAL Your Vulcan-Hart Gas Fryer is produced with quality workmanship and material. Proper installation, usage and maintenance will result in many years of satisfactory performance. It is suggested that you thoroughly read this entire manual and carefully follow all of the instructions provided. INSTALLATION Before installing the fryer, verify that the type of gas (natural or p

Summary of the content on the page No. 4

LOCATION The equipment area must be kept free and clear of combustible substances. Minimum clearance from combustible construction is 6" (152.4mm) from the sides and 6" (152.4mm) from the back of the fryer; minimum clearance from non-combustible construction is 0" from the sides and back of the fryer. There must be at least 16" (406.4mm) clearance between the fryer and any open top flame units. Adequate clearances for servicing and proper operation must be allowed. Install the fryer in an area

Summary of the content on the page No. 5

STRAIN RELIEF FITTING FOR GAS LINE THIS SIDE ONLY. (To be supplied by others.) PL-51194 Fig. 1 GAS CONNECTIONS All gas supply connections and any pipe joint compound must be resistant to the action of liquefied petroleum gases. The gas inlet is located at the lower left rear. Codes require that a gas shutoff valve be installed in the gas line ahead of the fryer. 1 The gas supply line must be at least the equivalent of /2" (12.7mm) iron pipe. If using the optional quick- 3 3 1 disconnect flex h

Summary of the content on the page No. 6

LEVELING THE FRYER Once gas connections have been made, place a spirit level on top of the fryer. Adjust the legs to ensure that the fryer is level front-to-back and side-to-side in the final installed position. FLUE CONNECTIONS Adequate ventilation must be provided and must comply with NFPA Standard #96 (latest edition), and with local codes. Never make flue connections directly to the fryer. The fryer must be located under a hood which has an adequate connection to an exhaust duct. The hood

Summary of the content on the page No. 7

OPERATION WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. WARNING: SPILLING HOT OIL CAN CAUSE SEVERE BURNS. DO NOT MOVE FRYER WITHOUT DRAINING ALL OIL FROM THE TANK. Tank warranty may be voided by improper operation. Turn gas valve off when draining or filling. FILL FRY TANK WITH LIQUID SHORTENING CAUTION: Before turning the burners on, the fry tank must be filled with liquid shortening. If this is not done, the tank walls can be dama

Summary of the content on the page No. 8

LIGHTING THE PILOT 1. Turn thermostat OFF. Thermostat is located behind the door (Fig. 3). Drain Valve Gas Control Valve Knob Thermostat Knob PL-40677-1 MODEL EF3 Fig. 3 2. Push gas control valve knob and turn to OFF (Fig. 4). Wait 5 minutes for unburned gas to vent. 3. Push and turn gas control valve to the "I" in PILOT (Fig. 5). 4. While still holding knob in, light the pilot with a lit taper. Continue to depress knob until pilot remains lit when knob is released. If pilot does not remain

Summary of the content on the page No. 9

TURNING THE FRYER OFF 1. Turn the thermostat OFF. 2. Turn the gas control valve knob so the "I" in PILOT is opposite the INDEX. In this position, the pilot remains lit. 3. To shut off all gas to the system, including the pilot, turn the gas control valve knob to OFF. EXTENDED SHUTDOWN 1. Turn the manual gas shutoff valve OFF. 2. Turn the thermostat knob OFF. 3. Turn the gas control valve knob to OFF. Apply a thin film of cooking oil to the tank interior and the flue housing to inhibit rust. FRY

Summary of the content on the page No. 10

SHORTENING LIFE Shortening life may be extended by following these guidelines: • Do not salt foods over the fryer. • Use good quality shortening. • Filter shortening at least daily. • Replace shortening if it becomes poorly flavored. • Keep equipment and surroundings clean. • Set thermostats correctly. • Remove excess moisture and particles from food products before placing in fryer. Add approximately 15% new oil daily. Keep level of shortening at oil level line in fry tank. Add fresh shorteni

Summary of the content on the page No. 11

7. With a small amount of warm shortening, flush out scraps and sediment in the fry tank. Drain the tank thoroughly and wipe clean. 8. If it is necessary to clean the tank more thoroughly follow the procedure shown in CLEANING — WEEKLY OR AS REQUIRED. 9. Close the drain valve. 10. Pour the strained shortening back into the vat. 11. Add shortening to the "oil level" line. CLEANING Daily Clean your fryer regularly with a damp cloth and polish with a soft dry cloth. If regular cleaning is n

Summary of the content on the page No. 12

MAINTENANCE WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. WARNING: SPILLING HOT OIL CAN CAUSE SEVERE BURNS. DO NOT MOVE FRYER WITHOUT DRAINING ALL OIL FROM THE TANK. VENT Annually, when fryer is cool, check the flue and clear any obstructions. SERVICE AND PARTS INFORMATION To obtain service and parts information concerning this fryer, contact the Vulcan-Hart Service Agency in your area (refer to listing supplied with the fryer), or Vul


Alternative user manuals
# User manual Category Download
1 Vulcan-Hart 1GR45C ML-136414 User manual Fryer 3
2 Vulcan-Hart 1GR45CF ML-136791 User manual Fryer 1
3 Vulcan-Hart 1GR45M ML-136408 User manual Fryer 1
4 Vulcan-Hart 1GR65C ML-136415 User manual Fryer 2
5 Vulcan-Hart 1GR45MF ML-136785 User manual Fryer 0
6 Vulcan-Hart 1GR45D ML-136411 User manual Fryer 7
7 Vulcan-Hart 1GR45M User manual Fryer 2
8 Vulcan-Hart 1GR65CF ML-136792 User manual Fryer 0
9 Vulcan-Hart 1GR45DF ML-136778 User manual Fryer 0
10 Vulcan-Hart 1GR65M User manual Fryer 0
11 Vulcan-Hart 1GR65MF ML-136786 User manual Fryer 0
12 Vulcan-Hart 1GR65D ML-136412 User manual Fryer 9
13 Vulcan-Hart 1GR65DF ML-136789 User manual Fryer 1
14 Vulcan-Hart 1GR65M ML-136409 User manual Fryer 1
15 Vulcan-Hart 1GR85M ML-136410 User manual Fryer 0
16 Alto-Shaam Inc.ASF-75E User manual Fryer 1
17 Alto-Shaam FRY TECH ASF-75E User manual Fryer 1
18 Alto-Shaam Inc.Gas User manual Fryer 1
19 Alto-Shaam FRY TECH ASF-60E User manual Fryer 5
20 Alto-Shaam FRYTECH ASF-60G User manual Fryer 6