Vulcan-Hart 3GR45DF ML-136427 user manual

User manual for the device Vulcan-Hart 3GR45DF ML-136427

Device: Vulcan-Hart 3GR45DF ML-136427
Category: Fryer
Manufacturer: Vulcan-Hart
Size: 12.98 MB
Added : 3/15/2013
Number of pages: 27
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Vulcan-Hart 3GR45DF ML-136427. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Vulcan-Hart 3GR45DF ML-136427.

For your convenience

If looking through the Vulcan-Hart 3GR45DF ML-136427 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Vulcan-Hart 3GR45DF ML-136427 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Vulcan-Hart 3GR45DF ML-136427 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Vulcan-Hart 3GR45DF ML-136427 User manual - Online PDF
Advertisement
« Page 1 of 27 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Vulcan-Hart 3GR45DF ML-136427 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Vulcan-Hart 3GR45DF ML-136427. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1




INSTALLATION & OPERATIONAL MANUAL

GRD & GRC SERIES GAS FRYERS
With KleenScreen PLUS® Filtration Systems

MODELS:

1GR45D ML-136411
1GR45C ML-136414
1GR65D ML-136412
1GR65C ML-136415
1GR85D ML-136413
1GR85C ML-136416
1GR45DF ML-136778
1GR45CF ML-136791
1GR65DF ML-136789
1GR65CF ML-136792
1GR85DF ML-136790
1GR85CF ML-136793

Summary of the content on the page No. 2

GRDF / GRCF SERIES GAS FRYERS IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OBTAINED FROM THE LOCAL GAS SUPPLIER. IMPORTANT IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS AT THE M

Summary of the content on the page No. 3

GRDF / GRCF SERIES GAS FRYERS TABLE OF CONTENTS IMPORTANT FOR YOUR SAFETY………………………………………. 2 INTRODUCTION…………………………………………………………… 4 GENERAL…………………………………………………………… 4 ORDERING PARTS………………………………………………… 4 FRYER CAPACITIES………………………………………………. 4 UNPACKING………………………………………………………… 5 INSTALLATION……………………………………………………………. 5 Clearances…………………………………………………....6 Location ………………..……………………………….…. 6 CODES AND STANDARDS……………………………………….. 6 ASSEMBLY …………..…………………………………………… 7 FLUE CONNECTION……………

Summary of the content on the page No. 4

GRDF / GRCF SERIES GAS FRYERS INTRODUCTION GENERAL Vulcan Fryers are produced with quality workmanship and material. Proper installation, usage and maintenance will result in years of satisfactory performance. Before installing the fryer, thoroughly read this manual and carefully follow all instruction. This manual is applicable to model listed on the cover page. Procedures in this manual will apply to all models unless specified. Pictures and illustrations can be of any mode

Summary of the content on the page No. 5

GRDF / GRCF SERIES GAS FRYERS INSTALLATION Do not use the door or its handle to lift the fryer. Before installing the fryer, verify that the type of gas (natural or propane) agrees with the specifications on the fryer data plate, which is located on the inside of the door panel. Make sure the fryer is configured for the proper elevation. Record your fryer model, device, and serial numbers for future reference in the space provided below. This information can be found on the fry

Summary of the content on the page No. 6

GRDF / GRCF SERIES GAS FRYERS CODES AND STANDARDS The fryer must be installed in accordance with: In the United States: State and local codes, or in the absence of local codes, with: National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). Copies may be obtained from The American Gas Association Accredited Standards Committee Z223, @ 400 N. Capital St. NW, Washington, DC 20001 or the Secretary Standards Council, NFPA, 1 Batterymarch Park Quincy, MA 02169- 7471. NFPA

Summary of the content on the page No. 7

GRDF / GRCF SERIES GAS FRYERS FLUE CONNECTION Make the flue connection as follows: Comply with Vapor Removal from Cooking Equipment, ANSI-NFPA Standard #96 (latest edition), available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. Locate the fryer under a hood with adequate connection to an exhaust duct. The hood must extend 6” (15 cm) beyond fryer on both sides. Clearance above the fryer should be adequate for combustion byproducts to

Summary of the content on the page No. 8

GRDF / GRCF SERIES GAS FRYERS After piping has been checked for leaks, fully purge gas pipes to remove air. GAS PRESSURES (ALL MODELS): The gas pressure should be set at 4” W.C. (Water Column) (0.8 kPa) for natural gas and 10” W.C. (2.75 kPa) for propane gas. If incoming pressure exceeds ½ PSI (3.45 kPa), an additional pressure regulator must be installed. TESTING THE GAS SUPPLY PIPING SYSTEM: When test pressures exceed ½ PSI (3.45 kPa), the fryer and its individu

Summary of the content on the page No. 9

GRDF / GRCF SERIES GAS FRYERS In Australia, use only the caster supplied by the manufacturer for the fryer device. The fryer must be installed using a hose assembly restraining device to limit the movement of the appliance in accordance with AS1869. The fryer must be installed with a connector (not supplied by Vulcan) complying with the above codes. The fryer must be installed with restraining means to guard against transmission of strain to the connector. See illustration.

Summary of the content on the page No. 10

GRDF / GRCF SERIES GAS FRYERS BEFORE FIRST USE Cleaning New units are wiped down at the factory to remove any visible signs of dirt, oil, grease, etc. remaining from the manufacturing process. Before any food preparation, thoroughly wash the protective oil from all surface parts and the tank interior with hot soapy water to remove any film residue and dust or debris. Do not use chlorine or sulfate/sulfide cleaners. Wash any accessories shipped with unit. • Rinse fryer

Summary of the content on the page No. 11

GRDF / GRCF SERIES GAS FRYERS BASIC FRYING INSTRUCTION Set the desired temperature and allow shortening to heat up to that temperature. Fry items that are the same size to ensure equal doneness. Drain or wipe dry raw or wet foods to minimize splatter when lowering into hot shortening. Add fresh shortening as needed. Fry Basket Guidelines Do not overfill baskets. (See table for recommended basket capacities below) Carefully lower basket into oil. When frying dou

Summary of the content on the page No. 12

GRDF / GRCF SERIES GAS FRYERS TURNING ON THE FRYER Open the door to the fryer. Turn the power switch to the on position. Set temperature by turning the knob to the desired temperatures. The burners will light automatically. The burners will cycle on and off, maintaining the set temperature. EXTENDED SHUTDOWN 1. Thoroughly drain the fryer. Refer to DRAINING THE FRYER. 2. Clean the fryer according to CLEANING. 3. Turn off the main gas shutoff valve. FILTERING THE O

Summary of the content on the page No. 13

GRDF / GRCF SERIES GAS FRYERS Programming the Solid State Control VULCAN-HART F-32933 Rev. G (May 2009) -13-

Summary of the content on the page No. 14

GRDF / GRCF SERIES GAS FRYERS Programming the Computer Control VULCAN-HART F-32933 Rev. G (May 2009) -14-

Summary of the content on the page No. 15

GRDF / GRCF SERIES GAS FRYERS DRAINING THE TANK 1. Turn off fryer. 2. Insert the drain extension into the drain valve. Tighten only hand tight. 3. Direct the drain spout into the container that you want to drain the shortening into. 4. Open the drain valve. The oil will drain into the container. When the container is full or the fryer tank is empty, close the drain valve. Repeat this step until the fryer is empty. Remove the drain extension and place it back into the prov

Summary of the content on the page No. 16

GRDF / GRCF SERIES GAS FRYERS 7. Press the TEMP button again and the gas burners will heat the solution. Bring the solution to a simmer only. Allow to stand for a few minutes. 8. Turn OFF the power to the fryer. Drain the tank according to DRAINING THE TANK. Rinse thoroughly with clear, hot water. All traces of cleaner must be removed. Dry the tank thoroughly. 9. Close the drain valve and add shortening. Follow the FILLING TANK WITH SHORTENING procedure in this manual. The

Summary of the content on the page No. 17

GRDF / GRCF SERIES GAS FRYERS KleenScreen Plus® Filtration System Installation and Operational Manual for “DF” and “CF” Models GRD/CF and 2XGD/CF Models 2GR45DF Shown 2XG45DF Shown GAS KleenScreen PLUS® Models: 1GR45DF ML-136778 1GR45CF ML-136791 1GR65DF ML-136789 1GR65CF ML-136792 1GR85DF ML-136790 1GR85CF ML-136793 2GR45DF ML-136424 2GR45CF ML-136431 2GR6

Summary of the content on the page No. 18

GRDF / GRCF SERIES GAS FRYERS Filtering Instructions for KleenScreen PLUS® Fryers General The KleenScreen PLUS® filtration system filters the oil as it is pumped back into its’ respective tank(s). Only one tank can be drained and filtered at a time. Under no circumstances should both tanks be drained at the same time. Assembly • After unpacking, wash the filter pan, crumb basket and filter screen assembly. Make sure you remove the insert located inside the filter screen.

Summary of the content on the page No. 19

GRDF / GRCF SERIES GAS FRYERS Fully assembled filter screen assembly: Fig. 2 Secure Tube with Suction Tube Clip Filter Screen Lays Flat On Bottom of Filter Pan Fig. 3 Micro-Filtration Fabric Envelope Assembly: Same Suction Tube Fabric Envelope Insert (Different from Screen Assembly) Fabric Envelope Closing Clip Same Knurled Knob Fig. 4 VULCAN-HART

Summary of the content on the page No. 20

GRDF / GRCF SERIES GAS FRYERS INSTRUCTIONS TO REMOVE & REPLACE KLEENSCREEN PLUS® FILTER ENVELOPE FOR ABSOLUTE FILTRATION & MAXIMUM FLOW RATE WE RECOMMEND YOU CHANGE YOUR FILTER ENVELOPES AT EVERY OIL CHANGE (10-14 DAYS DEPENDING ON OIL USAGE). Step 1 Discard all oil from the filter vessel, (see pages 23 or 24). When the filter pan is empty, use a spatula and scrape off all debris left on the filter envelope and in the filter pan. Step 2 Unscrew “S” Tube from fil


Alternative user manuals
# User manual Category Download
1 Vulcan-Hart 1GR45C ML-136414 User manual Fryer 3
2 Vulcan-Hart 1GR45CF ML-136791 User manual Fryer 1
3 Vulcan-Hart 1GR45M ML-136408 User manual Fryer 1
4 Vulcan-Hart 1GR65C ML-136415 User manual Fryer 2
5 Vulcan-Hart 1GR45MF ML-136785 User manual Fryer 0
6 Vulcan-Hart 1GR45D ML-136411 User manual Fryer 7
7 Vulcan-Hart 1GR45M User manual Fryer 2
8 Vulcan-Hart 1GR65CF ML-136792 User manual Fryer 0
9 Vulcan-Hart 1GR45DF ML-136778 User manual Fryer 0
10 Vulcan-Hart 1GR65M User manual Fryer 0
11 Vulcan-Hart 1GR65MF ML-136786 User manual Fryer 0
12 Vulcan-Hart 1GR65D ML-136412 User manual Fryer 9
13 Vulcan-Hart 1GR65DF ML-136789 User manual Fryer 1
14 Vulcan-Hart 1GR65M ML-136409 User manual Fryer 1
15 Vulcan-Hart 1GR85M ML-136410 User manual Fryer 0
16 Alto-Shaam Inc.ASF-75E User manual Fryer 1
17 Alto-Shaam FRY TECH ASF-75E User manual Fryer 1
18 Alto-Shaam Inc.Gas User manual Fryer 1
19 Alto-Shaam FRY TECH ASF-60E User manual Fryer 5
20 Alto-Shaam FRYTECH ASF-60G User manual Fryer 6