Henny Penny CFA 600 user manual

User manual for the device Henny Penny CFA 600

Device: Henny Penny CFA 600
Category: Fryer
Manufacturer: Henny Penny
Size: 1.5 MB
Added : 1/7/2014
Number of pages: 100
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Henny Penny CFA 600. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Henny Penny CFA 600.

For your convenience

If looking through the Henny Penny CFA 600 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Henny Penny CFA 600 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Henny Penny CFA 600 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Henny Penny CFA 600 User manual - Online PDF
Advertisement
« Page 1 of 100 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Henny Penny CFA 600 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Henny Penny CFA 600. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Henny Penny
CFA Pressure Fryer
Electric Model 500
Gas Model 600
OPERATOR’S MANUAL

Summary of the content on the page No. 2

Summary of the content on the page No. 3

Model 500/600 This manual should be retained in a convenient location for future reference. A wiring diagram for this appliance is located on the rear shroud cover of the control panel. Post in a prominent location, instructions to be followed if user smells gas. This information should be obtained by consulting the local gas supplier. Do not obstruct the flow of combustion and ventilation air. Adequate clearance must be left all around appliance for sufficient air to the combustion chamber. Th

Summary of the content on the page No. 4

Model 500/600

Summary of the content on the page No. 5

Model 500/600 TABLE OF CONTENTS Section Page Section 1. INTRODUCTION ...........................................................................................1-1 1-1 Introduction...........................................................................................1-1 1-2 Proper Care .......................................................................................... 1-2 1-3 Assistance ....................................

Summary of the content on the page No. 6

Model 500/600 TABLE OF CONTENTS Section Page Section 4. PREVENTIVE MAINTENANCE 4-1 Preventive Maintenance Schedule ..........................................................4-1 4-2 Cleaning the Deadweight Valve ..............................................................4-2 4-3 Removal and Cleaning of Safety Relief Valve ..........................................4-3 4-4 Reversing Lid Gasket ............................................................................4-4 4-5 Checking Temperatur

Summary of the content on the page No. 7

Model 500/600 SECTION 1. INTRODUCTION The Henny Penny pressure fryer uses a combination of pressure, 1-1. INTRODUCTION heat, and time to produce a quality product. The advantage of this type fryer is the pressure allows the product to be cooked with less heat and less time than the conventional open-type fryers. The Chick-fil-A controls for the Henny Penny Models 500 (elec- tric) and 600 (gas) have many features to allow the Operator to produce consistent, quality products. The control

Summary of the content on the page No. 8

Model 500/600 As in any unit of food service equipment, the Henny Penny 1-2. PROPER CARE pressure fryer does require care and maintenance. Requirements for the maintenance and cleaning are contained in this manual and must become a regular part of the operation of the unit at all times. Should you require outside assistance, just call your local indepen- 1-3. ASSISTANCE dent Henny Penny distributor in your area, or call Henny Penny Corp. 1-800-417-8405 toll free or 1-937-456-8405. The Hen

Summary of the content on the page No. 9

Model 500/600 SECTION 2. INSTALLATION 2-1. INTRODUCTION This section provides the installation instructions for the Henny Penny pressure fryer. Installation of this unit should be performed only by a qualified service technician. Do not puncture the fryer with any objects such as drillsor screws as electrical shock or com- ponent damage could result. 2-2. UNPACKING 1. Cut the bands from around the carton. INSTRUCTIONS Any shipping damage should be noted in the presence of the

Summary of the content on the page No. 10

Model 500/600 2-2. UNPACKING 7. Close the front door. INSTRUCTIONS (Continued) Take care when moving the fryer to prevent personal injury. The fryer weighs approximately 300 lb (136 kg). 8. Tilt the fryer to one side so one side of the fryer frame is raised up off of the skid. 9. While one person holds the unit, another person hits the vertical wooden supports with a hammer pushing them under the fryer. 10. Return the fryer to fully upright. 11. Open front door, remove tw

Summary of the content on the page No. 11

Model 500/600 2-2. UNPACKING 14. Prepare deadweight valve assembly for operation. INSTRUCTIONS A metal shipping support is installed inside the dead- weight valveassembly and must be removed prior to installation and startup,or unit will NOT build pressure. 15. Unscrew the deadweight cap. 16. Remove the deadweight. ORIFICE 17. Remove and discard the shipping support. 18. Clean the deadweight orifice with a dry cloth. 19. Replace the deadweight and secure the deadweight cap. 20. Re

Summary of the content on the page No. 12

Model 500/600 2-3. SELECTING THE FRYER LOCATION (Continued) To prevent severe burns from splashing hot shortening, position and install fryer to prevent tipping or movement. Restraining ties may be used for stabilization. 2-4. LEVELING THE FRYER For proper operation, the fryer should be level from side to side and front to back. Place a level on the flat areas around the frypot collar, then adjust the leveling bolts or casters until the unit is level. FAILURE TO FOLLO

Summary of the content on the page No. 13

Model 500/600 2-4. VENTILATION 0F FRYER (Continued) 303 2-5

Summary of the content on the page No. 14

Model 500/600 The gas fryer is factory available for either natural or propane gas. 2-6. GAS SUPPLY Check the data plate behind the front door of the fryer to determine the proper gas supply requirements. Do not attempt to use any gas other than that specified on the data plate. Conversion kits can be installed by your distributor if required. Incorrect gas supply could cause an explosion or fire resulting in severe injuries and/or property damage. Please refer below for the recommended h

Summary of the content on the page No. 15

Model 500/600 Provisions should be made for moving the fryer for cleaning and 2-6. GAS SUPPLY (Continued) servicing. This may be accomplished by: 1. Installing a manual gas shut off valve and disconnect union, or 2. Installing a heavy duty design A.G.A. certified connector which complies with the Standard for Connectors for Moveable Gas Appliances, ANSI Z21.6, or CAN/CSA 6.16, with a quick- disconnect coupling (Henny Penny Part No. 19921), which complies with ANSI standard Z21.41, or CAN 1-

Summary of the content on the page No. 16

Model 500/600 2-8 303

Summary of the content on the page No. 17

Model 500/600 The gas pressure regulator on the automatic gas valve is factory set as 2-8. GAS PRESSURE follows: REGULATOR SETTINGS Natural: 3.5 inches water column Propane: 10.0 inches water column The gas pressure regulator has been set by Henny Penny and is not to be adjusted by the user. 2-9. GAS PILOT & BURNER Lighting Procedure - Solid State Ignition 1. Turn main power switch to OFF position. LIGHTING AND SHUTDOWN PROCEDURE 2. Move “ON/OFF” selector on gas control valv

Summary of the content on the page No. 18

Model 500/600 2-9. GAS PILOT & BURNER Lighting Procedure - Solid State Ignition LIGHTING AND SHUT 1. The gas valve knob has a dual function. a. Complete control of gas to the pilot and main burner. DOWN PROCEDURES b. When in the pilot position, it is the reset mechanism for the (Continued) automatic pilot. 2. Partially press and turn the gas valve knob to the OFF position. 3. Wait at least 5 minutes to allow any gas to escape that may have accumulated in t

Summary of the content on the page No. 19

Model 500/600 2-10. PRESSURE The gas regulator is preset at the factory at 3.5 inch water column (0.87 REGULATOR kPa) for natural gas (10.0 inch (2.49 kPa) for propane). If adjustment is ADJUSTMENT necessary, contact your local independent Henny Penny distributor. (GAS ONLY) 2-11. ELECTRICAL The gas fryer requires 120 single phase, 60 Hertz, 10 or 5 amp, 2 wire REQUIREMENTS + ground service. The gas fryer is factory equipped with a grounded (GAS FRYER) cord and p

Summary of the content on the page No. 20

Model 500/600 The electric fryer requires 208 or 240 volt, three phase, 50/60 2-12. ELECTRICAL Hertz service. The power cord may be already attached to the REQUIREMENTS (ELECTRIC FRYER) fryer or provided at installation. Check the data plate behind the front door to determine the correct power supply. This fryer must be adequately and safely grounded (earthed) or electrical shock could result. Refer to local electrical codes for correct grounding (earthing) procedures or


Alternative user manuals
# User manual Category Download
1 Henny Penny 324 User manual Fryer 74
2 Henny Penny 302 User manual Fryer 31
3 Henny Penny 341 User manual Fryer 15
4 Henny Penny 322 User manual Fryer 79
5 Henny Penny 323 User manual Fryer 12
6 Henny Penny 301 User manual Fryer 3
7 Henny Penny 500 User manual Fryer 144
8 Henny Penny 291 User manual Fryer 1
9 Henny Penny 303 User manual Fryer 6
10 Henny Penny 580 KFC User manual Fryer 63
11 Henny Penny 561 User manual Fryer 26
12 Henny Penny 580 User manual Fryer 11
13 Henny Penny 581 User manual Fryer 15
14 Henny Penny 342 User manual Fryer 7
15 Henny Penny 680 KFC User manual Fryer 135
16 Alto-Shaam Inc.ASF-75E User manual Fryer 1
17 Alto-Shaam FRY TECH ASF-75E User manual Fryer 1
18 Alto-Shaam Inc.Gas User manual Fryer 1
19 Alto-Shaam FRY TECH ASF-60E User manual Fryer 5
20 Alto-Shaam FRYTECH ASF-60G User manual Fryer 6