Frymaster D50 Series user manual

User manual for the device Frymaster D50 Series

Device: Frymaster D50 Series
Category: Fryer
Manufacturer: Frymaster
Size: 1.04 MB
Added : 10/8/2013
Number of pages: 44
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Frymaster D50 Series. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Frymaster D50 Series.

For your convenience

If looking through the Frymaster D50 Series user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Frymaster D50 Series on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Frymaster D50 Series to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Frymaster D50 Series User manual - Online PDF
Advertisement
« Page 1 of 44 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Frymaster D50 Series but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Frymaster D50 Series. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Decathlon Series Gas Fryers (CE)
Installation & Operation Manual
D20, D50, D60 & D80 Series
CE ONLY
Price: $10.00
*8195706*
Service Hotline 1-318-865-1711
819-5706
JUNE 2002

Summary of the content on the page No. 2

Summary of the content on the page No. 3

DANGER The front ledge of the fryer is not a step. Do not stand on the fryer. Serious injury can result from slips or contact with the hot oil. DANGER Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. DANGER Instructions to be followed in the event the operator smells gas or otherwise detects a gas leak must be posted in a prominent location. This information can be obtained from the local gas company or gas supplier. DANGER

Summary of the content on the page No. 4

Decathlon Series Gas Fryers (CE) Installation & Operation Manual TABLE OF CONTENTS Page # 1. INTRODUCTION 1-1 1.1 Applicability and Validity 1-1 1.2 After Purchase 1-1 1.3 Ordering Parts

Summary of the content on the page No. 5

Decathlon Series Gas Fryers (CE) Installation & Operation Manual TABLE OF CONTENTS (CONT.) Page # 4. FRYER OPERATIONS 4-1 4.1 Initial Start-up 4-1 4.2 Boil-Out Procedure 4-3 4.3 Final Preparation

Summary of the content on the page No. 6

FINDING YOUR WAY AROUND THE DEAN DECATHLON Basket Hanger Flue Cap Frypot Top Cap Electronic Operating Thermostat Burners 1.5” Round Drains Drain Tubes Drain Valve Handle (Red) Filter Unit Oil Return Handle (Yellow) Drain Flush Handle (Blue) Drain Tubes 3” Round Drains (SCFD models) A

Summary of the content on the page No. 7

DECATHLON SERIES GAS FRYERS (CE) CHAPTER 1: INTRODUCTION 1.1 Applicability and Validity The Dean Decathlon Series gas model family has been approved by the European Union (EU) for sale and installation in the following EU countries: AT, BE, KE, KD, ES, FI, FR, GB, IE, IT, LU, NL, NO, PT and SE. This manual is applicable to and valid for all Dean Decathlon gas units sold in English- speaking countries, including those in the European Union. Where conflicts exist between instruct

Summary of the content on the page No. 8

DECATHLON SERIES GAS FRYERS (CE) CHAPTER 1: INTRODUCTION 1.4 Service Information Call the Dean Service Hotline, 1-800-551-8633, for the location of your nearest factory authorized service center. To assist you more efficiently, always provide the service technician with the model number, gas type, serial number, and the nature of the problem. 1.5 Computer Information This equipment has been tested and found to comply with the limits for a Class A digital device, pursuan

Summary of the content on the page No. 9

DECATHLON SERIES GAS FRYERS (CE) CHAPTER 1: INTRODUCTION 1.6 Safety Information (cont.) WARNING boxes contain information about actions or conditions that may cause or result in damage to your system, and which may cause your system to malfunction. WARNING Example of a WARNING box. DANGER boxes contain information about actions or conditions that may cause or result in injury to personnel, and which may cause damage to your system and/or cause your system to malfunction.

Summary of the content on the page No. 10

DECATHLON SERIES GAS FRYERS (CE) CHAPTER 2: IMPORTANT INFORMATION 2.1 Receiving and Unpacking Equipment A. Check that the container is upright. Use an outward prying motion - no hammering - to remove the carton. Unpack the fryer carefully and remove all accessories from the carton. Do not discard or misplace these, as they will be needed. B. After unpacking, immediately check the equipment for visible signs of shipping damage. If damage has occurred, contact the carrier and fi

Summary of the content on the page No. 11

DECATHLON SERIES GAS FRYERS (CE) CHAPTER 2: IMPORTANT INFORMATION 2.2 General (cont.) Where conflicts exist between instructions and information in this manual and local code or national codes, or regulations, installation and operation shall comply with the codes or regulations in force in the country in which the equipment is installed. CAUTION Building codes prohibit a fryer with its open tank of hot oil/shortening from being installed beside an open flame of any type,

Summary of the content on the page No. 12

DECATHLON SERIES GAS FRYERS (CE) CHAPTER 2: IMPORTANT INFORMATION 2.4 Rating Plate This is attached to the inside right-hand corner of the front door panel. Information provided includes the model and serial number of the fryer, kW/hr (BTU/hr) of the burners, outlet gas pressure in mbars (inches W.C.) and whether the unit has natural or propane gas orifices. DANGER Fryers MUST be connected ONLY to the gas type identified on the attached rating plate. 2.5 Pre-Installation

Summary of the content on the page No. 13

Summary of the content on the page No. 14

DECATHLON SERIES GAS FRYERS (CE) CHAPTER 2: IMPORTANT INFORMATION 2.6 Air Supply and Ventilation (cont.) F. Adequate distance must be maintained from the flue outlet of the fryer(s) to the lower edge of the filter bank. Per NFPA Standards No. 96, a minimum of 45-cm (18-inches) should be maintained between the flue(s) and the lower edge of the exhaust hood filter. G. Filters and drip troughs should be part of any industrial hood, but consult local codes before constructing and

Summary of the content on the page No. 15

DECATHLON SERIES GAS FRYERS (CE) CHAPTER 3: INSTALLATION 3.1 Installing the Fryer A. Initial Installation: If the fryer is installed with legs, do not push the fryer to adjust its position. Use a pallet or lift jack to lift the fryer slightly, then place the fryer where it is to be installed. B. Relocating the fryer: Remove all weight from each leg before moving a fryer with legs installed. Do not slide the fryer on the legs. C. If a leg becomes damaged, contact your service agent

Summary of the content on the page No. 16

Summary of the content on the page No. 17

DECATHLON SERIES GAS FRYERS (CE) CHAPTER 3: INSTALLATION 3.4 Gas Categories Installation shall be made with a gas connector that complies with national and local codes. Quick disconnect devices, if used, shall likewise comply with national and local codes. WARNING The fryer MUST be connected to the gas supply specified on the rating and serial number plate located on the back of the fryer door. WARNING If gas odors are detected, the gas supply MUST be shut off at

Summary of the content on the page No. 18

DECATHLON SERIES GAS FRYERS (CE) CHAPTER 3: INSTALLATION 3.5 Gas Connections DANGER Before connecting new pipe to this appliance the pipe must be blown out thoroughly to remove all foreign material. Foreign material in the burner and gas controls will cause improper and dangerous operation. A. The gas supply (service) line must be the same size or greater than the fryer inlet line. This fryer is equipped with a 22 mm (3/4") male inlet. The gas supply line must be sized to

Summary of the content on the page No. 19

DECATHLON SERIES GAS FRYERS (CE) CHAPTER 3: INSTALLATION 3.5 Gas Connections (cont.) C. Manual shut-off valve: This gas service supplier-installed valve must be installed in the gas service line ahead of the fryers in the gas stream and in a position where it can be reached quickly in the event of an emergency. D. Regulating Gas Pressure: The fryer and shut-off valve must be disconnected from the gas supply during any pressure testing of the system. 1. External gas regulato

Summary of the content on the page No. 20

DECATHLON SERIES GAS FRYERS (CE) CHAPTER 3: INSTALLATION 3.5 Gas Connections (cont.) H. Orifices: The fryer can be configured to operate on any available gas. The correct safety control valve, appropriate gas orifices, and pilot burner are installed at the factory. While the valve can be adjusted in the field, only qualified service personnel should make any adjustments with the proper test equipment. 1. The following color codes indicate the type of gas to be used for each


Alternative user manuals
# User manual Category Download
1 Frymaster 1814 User manual Fryer 154
2 Frymaster 35 Series User manual Fryer 66
3 Frymaster 2836 Series User manual Fryer 6
4 Frymaster 45 User manual Fryer 34
5 Frymaster 45 Series User manual Fryer 16
6 Frymaster 1814E User manual Fryer 28
7 Frymaster 24G Series User manual Fryer 6
8 Frymaster 2836 User manual Fryer 9
9 Frymaster 35 User manual Fryer 21
10 Frymaster 8195916 User manual Fryer 13
11 Frymaster 47 Series User manual Fryer 10
12 Frymaster 45 y User manual Fryer 10
13 Frymaster 819-6213 User manual Fryer 5
14 Frymaster 819-5432 User manual Fryer 11
15 Frymaster 8196321 User manual Fryer 7
16 Alto-Shaam Inc.ASF-75E User manual Fryer 1
17 Alto-Shaam FRY TECH ASF-75E User manual Fryer 1
18 Alto-Shaam Inc.Gas User manual Fryer 1
19 Alto-Shaam FRY TECH ASF-60E User manual Fryer 5
20 Alto-Shaam FRYTECH ASF-60G User manual Fryer 6