Our goal is to provide you with a quick access to the content of the user manual for Frymaster CF Series. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Frymaster CF Series.

For your convenience

If looking through the Frymaster CF Series user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Frymaster CF Series on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Frymaster CF Series to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Frymaster CF Series User manual - Online PDF
Advertisement
« Page 1 of 50 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Frymaster CF Series but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Frymaster CF Series. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 15

CF SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS 2.4 Connection to Gas Line DANGER Before connecting new pipe to this appliance, the pipe must be blown out thoroughly to remove all foreign material. Foreign material in the burner and gas controls will cause improper and dangerous operation. DANGER When pressure-testing incoming gas supply lines, disconnect the fryer from the gas line if the test pressure will be ½ PSIG (3.45 kPa, 13.84 inches W.C.) or greate

Summary of the content on the page No. 16

CF SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS Gas Connection Pipe Sizes [Minimum incoming pipe size should be 1-1/2" (38 mm)] 4 or more Gas Single Unit 2 - 3 Units units* Natural 3/4" (19 mm) 1" (25 mm) 1-1/4" (33 mm) Propane 1/2" (13 mm) 3/4" (19 mm) 1" (25 mm) Manufactured 1" (25 mm) 1-1/4" (33 mm) 1-1/2" (38 mm) * For distances of more than 20 feet (6 m) and/or more than four fittings or elbows, increase the connection by one pipe size. CE Standard 3 CE regulati

Summary of the content on the page No. 17

CF SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS 3. Close the fryer drain valve and fill the frypot with water and boil-out solution to the bottom OIL- LEVEL line at the rear of the frypot. Light the fryer and perform the boil-out procedures that are described in the "Lighting Instructions" and "Boiling Out the Frypot" topics found in Chapter 3 of this manual. (non-KFC co-branded locations only) DANGER "Dry-firing" your unit will cause damage to the frypot and can cau

Summary of the content on the page No. 18

CF SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS DANGER This appliance was configured at the factory for a specific type of gas. Converting from one type of gas to another requires the installation of specific gas-conversion components. DANGER Switching to a different type of gas without installing the proper conversion kit may result in fire or explosion! NEVER ATTACH THIS APPLIANCE TO A GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED! Conversion of this applian

Summary of the content on the page No. 19

CF SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS The following gas-conversion components and kits are available from your FASC: CE Only: Propane (G31) to Natural (G20/G25) Regulator only: P/N 810-1292 Pilot, regulator, and orifices kit: P/N 826-1478 Natural (G20/G25) to Propane (G31) Regulator only: P/N 810-1292 Pilot, regulator, and orifices kit: P/N 826-1204 Non-CE Only: Propane (G31) to Natural (G20/G25) Regulator Conversion Kit: P/N 807-1849

Summary of the content on the page No. 20

CF SERIES GAS FRYERS CHAPTER 3: OPERATING INSTRUCTIONS 3.1 Start-Up Procedure DANGER Never operate this appliance with an empty frypot. The frypot must be filled with water (non-KFC co-branded locations) or cooking oil/shortening before lighting the burners. Failure to do so will damage the frypot and may cause a fire. WARNING The on-site supervisor is responsible for ensuring that operators are made aware of the inherent hazards of operating a hot oil filtering system, particularly the as

Summary of the content on the page No. 1


CF Series Gas Fryers
Installation and Operation Manual








Series FMCF, FMCFE, FMCFEC,
MJCF, MJCFE, MJCFEC, KJ3FC,
JCFX, J3F & J65X.







NON-CE &


Frymaster, a member of the Commercial Food Equipment Service Association, recommends
using CFESA Certified Technicians.

24-Hour Service Hotline 1-800-551-8633
PRINTED IN
THE UNITED *8195613*
www.frymaster.com
STATES
Email: service@frymaster.com
APRIL 2005

Summary of the content on the page No. 2

NOTICE This appliance is intended for professional use only and is to be operated by qualified personnel only. A Frymaster/DEAN Factory Authorized Service Center (FASC) or other qualified professional should perform installation, maintenance, and repairs. Installation, maintenance, or repairs by unqualified personnel may void the manufacturer’s warranty. See Chapter 1 of this manual for definitions of qualified personnel. NOTICE This equipment must be installed in accordance with

Summary of the content on the page No. 3

DANGER Adequate means must be provided to limit the movement of this appliance without depending upon the gas line connection. Single fryers equipped with legs must be stabilized by installing anchor straps. All fryers equipped with casters must be stabilized by installing restraining chains. If a flexible gas line is used, an additional restraining cable must be connected at all times when the fryer is in use. DANGER The front ledge of the fryer is not a step! Do not stand on t

Summary of the content on the page No. 4

CF Series Gas Fryers TABLE OF CONTENTS PAGE # CHAPTER 1: General Information 1.1 Applicability and Validity..............................................................................................................1-1 1.2 Parts Ordering and Service Information.........................................................................................1-1 1.3 Safety Information........................................................................................

Summary of the content on the page No. 5

CF SERIES GAS FRYERS CHAPTER 1: INTRODUCTION 1.1 Applicability and Validity The CF Series Gas Fryer model family has been approved by the European Union for sale and installation in the following EU countries: AT, BE, DE, DK, ES, FI, FR, GB, IE, IT, LU, NL, NO, PT and SE. This manual is applicable to and valid for all CF Series Gas Fryer units sold in English- speaking countries, including those in the European Union. Where conflicts exist between instructions and information

Summary of the content on the page No. 6

CF SERIES GAS FRYERS CHAPTER 1: INTRODUCTION 1.3 Safety Information Before attempting to operate your unit, read the instructions in this manual thoroughly. Your fryer is equipped with two automatic safety features: • High temperature detection shuts off gas to the burner assembly should the controlling thermostat fail. • A safety switch built into the drain valve of units with built-in filtration systems prevents burner ignition with the drain valve even partially open.

Summary of the content on the page No. 7

CF SERIES GAS FRYERS CHAPTER 1: INTRODUCTION 1.5 Equipment Description CF Series gas fryers are specifically designed for high volume frying, especially fish, chicken and other breaded products. Models in this series include FMCF, FMCFE, FMCFEC, MJCF, MJCFE, MJCFEC, KJ3FC and J65X variants. (The J65X variant is a drop-in unit without cabinetry.) Fryers in this series may be equipped with built-in Filter Magic filtration systems (FMCF variants), or may be configured for manual

Summary of the content on the page No. 8

CF SERIES GAS FRYERS CHAPTER 1: INTRODUCTION 1.6 Installation, Operating, and Service Personnel Operating information for Frymaster equipment has been prepared for use by qualified and/or authorized personnel only, as defined in Section 1.7. All installation and service on Frymaster equipment must be performed by qualified, certified, licensed, and or/authorized installation or service personnel, as defined in Section 1.7. 1.7 Definitions QUALIFIED AND/OR AUTHORIZED OP

Summary of the content on the page No. 9

CF SERIES GAS FRYERS CHAPTER 1: INTRODUCTION 1.8 Shipping Damage Claim Procedure Your Frymaster equipment was carefully inspected and packed before leaving the factory. The transportation company assumes full responsibility for safe delivery upon acceptance of the equipment for transport. What to do if your equipment arrives damaged: 1. File a claim for damages immediately, regardless of the extent of damages. 2. Inspect for and record all visible loss or damage, and ens

Summary of the content on the page No. 10

CF SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS 2.1 General Installation Requirements Qualified, licensed, and/or authorized installation or service personnel, as defined in Section 1.7 of this manual, should perform all installation and service on Frymaster equipment. Conversion of this appliance from one type of gas to another should only be performed by qualified, licensed, and/or authorized installation or service personnel as defined in Section 1.7 of this manua

Summary of the content on the page No. 11

CF SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS CLEARANCE AND VENTILATION DANGER No structural material on the fryer should be altered or removed to accommodate placement of the fryer under a hood. Questions? Call the Frymaster/Dean Service Hotline at 1-800-551-8633. DANGER This appliance must be installed with sufficient ventilation to prevent the occurrence of unacceptable concentrations of substances harmful to the health of personnel in the room in which

Summary of the content on the page No. 12

CF SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS NATIONAL CODE REQUIREMENTS The type of gas for which the fryer is equipped is stamped on the data plate attached to the inside of the fryer door. Connect a fryer stamped "NAT" only to natural gas, those stamped "PRO" only to propane gas, and those stamped "MFG" only to manufactured gas. Installation shall be made with a gas connector that complies with national and local codes, and, where applicable, CE codes. Quick-Di

Summary of the content on the page No. 13

CF SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS If necessary, the user should consult the dealer or an experienced radio and television technician for additional suggestions. The user may find the booklet "How to Identify and Resolve Radio-TV Interference Problems" helpful. It is prepared by the Federal Communications Commission and is available from the U.S. Government Printing Office, Washington, DC 20402, Stock No. 004-000-00345-4. 2.2 Caster/Leg Installation

Summary of the content on the page No. 14

CF SERIES GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS 3. Level fryers equipped with legs by screwing out the legs approximately 1 inch, and then adjust them so that the fryer is level and at the proper height in the exhaust hood. Frymaster recommends that the minimum distance from the flue outlet to the bottom edge of the filter be 24 inches (600 mm) when the appliance consumes more than 120,000 BTU per hour. For fryers equipped with casters, there are no built-in leveling de


Alternative user manuals
# User manual Category Download
1 Frymaster 1814 User manual Fryer 154
2 Frymaster 35 Series User manual Fryer 66
3 Frymaster 2836 Series User manual Fryer 6
4 Frymaster 45 User manual Fryer 34
5 Frymaster 45 Series User manual Fryer 16
6 Frymaster 1814E User manual Fryer 28
7 Frymaster 24G Series User manual Fryer 6
8 Frymaster 2836 User manual Fryer 9
9 Frymaster 35 User manual Fryer 21
10 Frymaster 8195916 User manual Fryer 13
11 Frymaster 47 Series User manual Fryer 10
12 Frymaster 45 y User manual Fryer 10
13 Frymaster 819-6213 User manual Fryer 5
14 Frymaster 819-5432 User manual Fryer 11
15 Frymaster 8196321 User manual Fryer 7
16 Alto-Shaam Inc.ASF-75E User manual Fryer 1
17 Alto-Shaam FRY TECH ASF-75E User manual Fryer 1
18 Alto-Shaam Inc.Gas User manual Fryer 1
19 Alto-Shaam FRY TECH ASF-60E User manual Fryer 5
20 Alto-Shaam FRYTECH ASF-60G User manual Fryer 6