Frymaster 8196606 user manual

User manual for the device Frymaster 8196606

Device: Frymaster 8196606
Category: Fryer
Manufacturer: Frymaster
Size: 1.36 MB
Added : 4/1/2014
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Frymaster 8196606. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Frymaster 8196606.

For your convenience

If looking through the Frymaster 8196606 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Frymaster 8196606 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Frymaster 8196606 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Frymaster 8196606 User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Frymaster 8196606 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Frymaster 8196606. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


UHC-HD
Service, Parts Manual for 6, 3-Row Models








Frymaster, a member of the Commercial Food Equipment Service Association, recommends
using CFESA Certified Technicians.

Price: $6.00
24-Hour Service Hotline
*8196606*
819-6606
1-800-551-8633
NOV 10

Summary of the content on the page No. 2

NOTICE IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS ENODIS EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY FROM FRYMASTER DEAN, OR ANY OF ITS AUTHORIZED SERVICE CENTERS, AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. FURTHER, FRYMASTER DEAN AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN P

Summary of the content on the page No. 3

Table of Contents Theory of Operation 1-1 Service/Software Procedures 2-1 Troubleshooting 3-1 Illustrated Parts List 4-1 Wiring Diagrams 5-1

Summary of the content on the page No. 4

Cabinet Service Procedures 1 Functional Description Master Control Display Power switch Timer: displays on row board remaining time for all active timers. Temperature: displays on Row Mode key row board plate temperature, alternating Timer keys between top and bottom. Timer key Note:The illustrations for  these service procedures  are of the 6‐row full size  UHC‐HD. 1.2 Theory of Operation The cabinet operates on 208-250VAC 50 or 60 cycle

Summary of the content on the page No. 5

Cabinet Service Procedures 1.3 Start Up Indicators and Test Points Distribution boards shown with ribbon cables removed. Upon startup, the cabinet beeps. LED’s on the distribution boards flash. The displays show the version number of the cabinet’s firmware and then the row’s status. 1-2

Summary of the content on the page No. 6

Cabinet Service Procedures 2 Service Procedures DANGER: Failure to disconnect power from the unit before servicing could result in serious injury or death. The cabinet power switch DOES NOT disconnect all incoming power to the cabinet. Fig. 2: Tabs in the topcap extend to  holes in the cabinet. The top is secured  with at the tabs with screws.  Fig. 1: The sides  are held in place  by screws near  the base of the  unit on each side.  2.1 Updating Softwa

Summary of the content on the page No. 7

Cabinet Service Procedures Update: Boards Loading Sequence  Software should be loaded in this  1. Turn power off. sequence:  2. Insert flash drive in USB port located on cabinet bezel. • Main Board  3. Turn power on. 4. Cabinet displays version numbers followed by current menu • Language  setting. • Row Display  5. Press programming key. • Distribution Boards  6. Screen scrolls Enter Access Sequence. If the software update only involves a few  7. Enter 98765 with keypad. of the comp

Summary of the content on the page No. 8

Cabinet Service Procedures USB. 6. Press OK. 7. The master control displays Please Wait… as files are transferred to the flash drive, changing to the number of files copied when the process is complete. 8. Press OK. 9. Remove flash drive. 10. Cabinet returns to normal display. Configure Cabinet with Menu/Configuration Captured on another Cabinet 1. Place a flash drive with only a captured menu/cabinet configuration in the root file into the USB port of a cabinet to be identical

Summary of the content on the page No. 9

Cabinet Service Procedures 2.2 Placing the cabinet in Service Mode The cabinet can be put in service mode, a diagnostic settings which allows the heater plates to be controlled individually, brightness settings on the displays adjusted and re-addressing for unique arrangements of bezels. Follow the steps below : Switching Heater Plates Off Individually When troubleshooting, it may be useful to switch heater plates off individually. Follow the instructions below: 1. Press the p

Summary of the content on the page No. 10

Cabinet Service Procedures Readdressing the Cabinet Addressing, or assigning a position-specific component such as a display or distribution board, is done automatically by the cabinet on startup. Communication errors can occur on start-up after a board installation however. If so, follow the instructions below to readdress the cabinet. This process can also be used during troubleshooting when displays are connected out of synch with their associated bezel on the same row level. 1. Pr

Summary of the content on the page No. 11

Cabinet Service Procedures 2.3 Accessing the Electronic Components 1. The component shelf is accessed by removing two screws on each side of the unit (Fig. 1). 2. Lift and remove the sides, which exposes screws that hold the top in place (Fig. 2). 3. The components are annotated below (Fig. 3). Master Display Board Fans: a NOTE: rThe e spe  cooling cific to  fans  LON board regions of the cabinet rest on ducts, and cool  Master Control and ducted to direct specific re

Summary of the content on the page No. 12

Cabinet Service Procedures • ERR LED toggles when a communication error is detected; it’s not unusual to see a flash, but regular flashing means communications problems. • LED5 and LED6 used for programming/debugging; have no diagnostic function. • LED7 When lit, the master control is executing a time or temp query operation on the front side. • LED8 When lit, the master control is executing a time or temp query operation on the back side. Distribution Board • HB LED is a heartbea

Summary of the content on the page No. 13

Cabinet Service Procedures suspect heater. Note: Line voltage is only seen when the row is calling for heat. 2. Check for line voltage between the power input terminal and the terminal block. 3. Check for +5VDC at the power-in terminal and the terminal block for the power supply. NOTE: After testing, reconnect all connections to their original positions. 2.5.4 Display 1. Remove power from unit. 2. Connect the ribbon cable from a suspect display to the connector of a proper

Summary of the content on the page No. 14

Cabinet Service Procedures 3. HHHH means RTD indicates the temperature is above 255°F (124°C), but below "Open" circuit resistance, which causes SENS ALARM. 4. UHC VERSION _ _ _ (version number will vary) appears for five seconds when the unit is turned on. 5. The cabinet also displays a variety of error messages, which are shown on page 3-1. 2.6 Removing/Replacing Bezels 1. Remove power from unit. 2. Remove screws at the base of each side and remove side panels. (See figure 7.)

Summary of the content on the page No. 15

Cabinet Service Procedures 2.6. 1 Removing/Replacing a Distribution Board or Communication Board 1. Remove power. 2. Remove and mark the wires on the faulty component. 3. Remove the board by lifting it from its standoffs. 4. Position the new board and attach wires. 5. Reapply power. 6. Run readdress steps on page 2-4. 2.6.2 Removing a Row 1. Remove the sides and top as shown in earlier steps. Disconnect the faulty row from the distribution board, and terminal block. 2.

Summary of the content on the page No. 16

Cabinet Service Procedures 9. Slide the row assembly completely into the cabinet and return the spacers between the heater plates. Ensure the row is evenly positioned in the cabinet. There must be sufficient space to allow the bezel tabs to fit between the outside row plate and the cabinet interior wall. 10. Replace the bezels. Fig. 12: The heater plate slides from the insulation.  CAUTION Ensure the heater plate setscrews are tightened securely to the spacer. Tightening th

Summary of the content on the page No. 17

Cabinet Troubleshooting The master control display and the row displays show error messages when there is a problem. The messages are shown in the matrix below along with possible causes and diagnostic tests. Error Message Cause Tests The master control board has lost  • Turn the cabinet off and back on.  Call service row display communication with the specified  • Ensure there are no software  error  board.  incompatibilities.  Row number also displayed * • Inspect ribbon cable

Summary of the content on the page No. 18

Cabinet Troubleshooting Failure modes not accompanied by a master control display are shown below with possible causes and tests. Symptom Possible Causes Tests • No power to cord. • Check for line voltage at the switch Unit fails to power and the transformer. • Blown 20 amp fuse. up; fans don’t run. • Reset circuit breaker. • Circuit breaker open. Unit powers up and • Broken or improperly • Switch ribbon cable from functioning fans run; a display seated ribbon cable. display

Summary of the content on the page No. 19

Cabinet Parts Parts Lists, Exploded Views 3 1 2 4 7 6 8 5 9 11 10 12 13 14 Part Number Description Item 1 108-1897 Top Cap 2 823-7636 Rear Fascia 3 807-4882 Circuit Breaker, 16 amp 4 807-5111 Time/Temperature switch 5 807-4911 Power switch 6 823-7513 Front fascia 7 807-5112 Master control overlay with ribbon cable * 807-5156 Master display board (circuit board in master display assembly) 4-1

Summary of the content on the page No. 20

Cabinet Parts Part Number Description Item 8 807-5111 Time/Temperature switch 9 826-2781 Bezel, with boards, front with short ribbon cable * 826-2782 Bezel with boards, rear, with long ribbon cable 10 108-1190 Base 11 807-4857 Heater plate/RTD 12 807-4860 Distribution board 13 108-1633 Side, left, vented 14 108-1632 Side right, not vented * 230-7245 Bottom bezel facia, front or rear Component Shelf 15 20 16 19 17 18 Par


Alternative user manuals
# User manual Category Download
1 Frymaster 1814 User manual Fryer 154
2 Frymaster 35 Series User manual Fryer 66
3 Frymaster 2836 Series User manual Fryer 6
4 Frymaster 45 User manual Fryer 34
5 Frymaster 45 Series User manual Fryer 16
6 Frymaster 1814E User manual Fryer 28
7 Frymaster 24G Series User manual Fryer 6
8 Frymaster 2836 User manual Fryer 9
9 Frymaster 35 User manual Fryer 21
10 Frymaster 8195916 User manual Fryer 13
11 Frymaster 47 Series User manual Fryer 10
12 Frymaster 45 y User manual Fryer 10
13 Frymaster 819-6213 User manual Fryer 5
14 Frymaster 819-5432 User manual Fryer 11
15 Frymaster 8196321 User manual Fryer 7
16 Alto-Shaam Inc.ASF-75E User manual Fryer 1
17 Alto-Shaam FRY TECH ASF-75E User manual Fryer 1
18 Alto-Shaam Inc.Gas User manual Fryer 1
19 Alto-Shaam FRY TECH ASF-60E User manual Fryer 5
20 Alto-Shaam FRYTECH ASF-60G User manual Fryer 6