United States Stove HOTBLAST 1300 user manual

User manual for the device United States Stove HOTBLAST 1300

Device: United States Stove HOTBLAST 1300
Category: Cell Phone
Manufacturer: United States Stove
Size: 0.27 MB
Added : 7/27/2013
Number of pages: 32
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for United States Stove HOTBLAST 1300. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with United States Stove HOTBLAST 1300.

For your convenience

If looking through the United States Stove HOTBLAST 1300 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual United States Stove HOTBLAST 1300 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual United States Stove HOTBLAST 1300 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
United States Stove HOTBLAST 1300 User manual - Online PDF
Advertisement
« Page 1 of 32 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual United States Stove HOTBLAST 1300 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to United States Stove HOTBLAST 1300. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

E
V
O
T
S
C
S
O
E
M
T
T
S
Model 1300/1400
OWNERS MANUAL
SOLID FUEL
WARM AIR FURNACE
*FOR PARALLEL INSTALLATION WITH
EXISTING FORCED AIR-GAS OR OIL
FIRED FURNACE (U.S. ONLY)
*FOR INSTALLATION AS A CENTRAL FURNACE
*CERTIFIED UNDER ANSI/UL 391 & CAN/CSA-B366.1-M91
IMPROPER INSTALLATION MAY VOID
CAUTION:
YOUR WARRANTY
READ ALL INSTRUCTIONS CARE-
FULLY BEFORE STARTING THE
INSTALLATION OR OPERATING DO NOT USE THIS FURNACE
THE FURNACE IN A MOBILE HOME OR TRAILER
UNITED STATES STO

Summary of the content on the page No. 2

CONGRATULATIONS! You've purchased one of America's Finest Wood and Coal Burning Furnaces. By heating with wood and coal you're helping CONSERVE AMERICA'S ENERGY! Wood is our Renewable Energy Resource. Please do your part to preserve our wood supply. Plant at least one tree each year. Future generations will thank you. NOTE: YOUR UNIT MUST BE INSTALLED BY A QUALIFIED FURNACE INSTALLER. TOOLS AND MATERIALS NEEDED TOOLS MATERIAL Pencil 6" Pipe, 6" Elbow, Collar and Thimble; 6 Foot Folding Rul

Summary of the content on the page No. 3

Caution Labels Your Furnace has the following labels. Read and Obey all labels. DANGER: RISK OF FIRE OR EXPLOSION. DO NOT burn garbage, gasoline, drain oil, or other flammable liquids. WARNING: FIRE HAZARD. DO NOT operate with fire draft exceeding .06 inches w.c. DO NOT operate with fuel loading or ash removal doors open. DO NOT store fuels, paints, thinners, flammable liquids, or other highly volatile substances in the furnace room. CAUTION: HOT SURFACES Keep children aw

Summary of the content on the page No. 4

Rules for safe installation and operation Read these rules and the instructions carefully. Failure to follow them will cause a hazard that could result in death, serious bodily injury, and/or property damage. 1. Check your local codes. The installation must comply with their rulings. 2. Do not install this furnace in a mobile home or trailer. 3. Always connect this furnace to a chimney and vent to the outside. Never vent to another room or inside a building. 4. Do not connect this furnace

Summary of the content on the page No. 5

HOW THE FURNACE FUNCTIONS PARALLEL INSTALLATION: (U.S. ONLY) Your HOTBLAST Furnace is designed (See Optional Wiring Diagram, Page 16, Fig. to be a supplemental or central heating source 15) The design is such that when the blower for your home. This Solid Fuel Furnace may comes on, the blower on the central system be installed in conjunction with a properly also comes on. The blower will only come on operating central furnace that is listed or cer- when the temperature in the plenu

Summary of the content on the page No. 6

DIMENSIONS OF FURNACE 41" Figure 1A Figure 1A 1300 1300 24-7/8" 21-1/32" 1-3/4" 33-7/8" 40-11/16" 9" 49-1/8" Figure 1B Figure 1B 1400 1400/1500 32-1/8" 24-1/16" 1-3/4" 33-7/8" 40-11/16" 9" 6

Summary of the content on the page No. 7

Locating the Furnace 18" 6" CHIMNEY 1. The furnace should be located in the same room as the central system and as close as possible, but not CENTRAL 12" 9" FURNACE closer than 9". There should be no wall between the furnace and the warm air outlet duct that is connected directly to the warm air outlet plenum of the central furnace. (See Fig. 2) 48" 2.The unit will require installation with the following clearances: Figure 2 Unit to sidewall............12"(305mm) Unit to backwall...........30"(

Summary of the content on the page No. 8

THIMBLE 6" ELBOW 6" SOLID DAMPER 6" BAROMETRIC DRAFT REGULATOR (OPTIONAL) 6" CHIMNEY NON-COMBUSTIBLE CONNECTOR WALL 6" ELBOW Chimney Connection Fig. 4 MASONRY CHIMNEY Before using an existing masonry chimney, clean the chimney and inspect the flue liner to be sure it is safe to use. Make repairs before attaching the furnace. See page 4, item 5. Look at Fig. 4. The connector pipe and fitt

Summary of the content on the page No. 9

Rules for Connector Pipe Installation NOTE: 1. The crimped end of the chimney connector fits A flue pipe shall not pass through an attic, inside the furnace flue collar. Install additional chim- roof space, closet or similar concealed space, a floor or ceiling of combustible construc- ney connectors and elbow with the CRIMPED END tion. Where passage through a wall or parti- TOWARD THE FURNACE. This will allow any tion is desired, installation must conform condensation in the flue to run back

Summary of the content on the page No. 10

CONNECTION OF CHIMNEY CONNECTOR TO A MASONRY CHIMNEY THROUGH A COMBUSTIBLE WALL Figure 8 shows how to connect the chimney connector of a heater to a masonry chimney through a combustible wall. There are five allowable ways that a chimney connector can be connected to a masonry chimney by passing through a combustible wall. NFPA Standard 211 allows the following wall pass-through systems. FIGURE 8 - CONNECTION OF CHIMNEY CONNECTOR TO A MA- SONRY CHIMNEY THROUGH A COMBUSTIBLE WALL CEILING SEE PAR

Summary of the content on the page No. 11

PART A, FIGURE 8 MINIMUM CHIMNEY CLEARANCE TO (FIGURE 8 CONTINUED ON NEXT PAGE) BRICK AND COMBUSTIBLES IS 2 IN. MINIMUM CLEARANCES 12 IN. OF BRICK ALL AROUND CHIMNEY CONNECTOR TO HEATER FIRE CLAY LINER MINIMUM 12 IN. (5/8" MIN. WALL THICKNESS) TO COMBUSTIBLES MASONRY CHIMNEY CONSTRUCTED TO MIN. 3-1/2" THICK BRICK NFPA 211 MASONRY WALL 1. Use a minimum 3-1/2" thick brick masonry wall framed into the combustible wall. A fireclay liner (ASTM C315 or equivalent) having a 5/8" minimum wall thickness

Summary of the content on the page No. 12

AIR SPACE PART B MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN. FIGURE 8 - (FIGURE 8 CONTINUED) FACTORY-BUILT MINIMUM CLEARANCE CHIMNEY LENGTH 9 IN. ALL AROUND NONSOLUBLE CHIMNEY CONNECTOR REFACTORY TO HEATER CEMENT CHIMNEY LENGTH FLUSH WITH INSIDE USE CHIMNEY MFRS. PARTS TO OF FLUE AIR SPACE ATTACH CONNECTOR SECURELY 9 IN. MINIMUM SOLID INSULATED, LISTED FACTORY-BUILT CHIMNEY LENGTH MASONRY CHIMNEY CONSTRUCTED SHEET STEEL SUPPORTS TO NFPA 211 (24 GAUGE M

Summary of the content on the page No. 13

Assembly of Furnace Your furnace requires the following items to be assembled or installed by the service person: Feed Door Pull Handle Feed Door Locking Handle Blower(s) and Blower Controls Electrical Connections Remove all parts from inside the furnace 1. Fig. 9 and inspect for damage, including the firebrick as some breakage could occur during shipment. Assemble the feed door pull handle as 2. shown in Figure 9. Install thermostat assembly and cover (complete with handle) as illustrated

Summary of the content on the page No. 14

LOAD LOAD FAN LIMIT FAN "OFF" LIMIT BREAK OFF INDICATOR INDICATOR LINE JUMPER FOR LINE LOW VOLTAGE FAN "ON" INDICATOR Honeywell LIMIT SWITCH R2 R1 WIRE COLOR CODE WIRE NUTS G- GREEN- GROUND WIRE COLOR CODE B- BLACK- POWER SUPPLY G - GREEN - GROUND W- WHITE- POWER SUPPLY B - BLACK - POWER SUPPLY R1- WHITE- FAN CONTROL W - WHITE - POWER SUPPLY GROUND R2- BLACK- FAN CONTROL R1 - WHITE - FAN CONTROL G M1- BLACK- BLOWER MOTOR R2 - BLACK - FAN CONTROL B G M1 - BLACK - BLOWER MOTOR M2- WHITE- BLOWER MO

Summary of the content on the page No. 15

Installation Pipe to combustible: Please see all methods of Installation in Sides: 18"(460mm) Appendix at the rear of this booklet. Back: 18"(460mm) This is a furnace, not a free standing stove. The installation must be made only on a noncom- You must direct heated air from 8" outlets away from bustible floor. the furnace, or it will not function properly. d) Install the smoke pipe connector to the chim- ney with

Summary of the content on the page No. 16

PLENUM 6" MIN. TO Figure 14 18" MIN. CEILING 2" MIN. AIR SPACE REQUIRED BY CODE CENTRAL FURNACE TO GAS/OIL/ELECTRIC TRANSFORMER AND Figure 15 COMBUSTION FAN OF SOLID FUEL UNIT COMBINATION CONTROL LIMIT H POWER SUPPLY JUMPER IN N FAN GAS/OIL/ELECTRIC POWER SUPPLY JUNCTION BOX CAUTION! DO NOT CONNECT PLENUM FAN CONTROL SWITCH ACROSS FURNACE LIMIT CONTROL. FURNACE BLOWER MOTOR Power Failure Instructions: Operation after loss of power-- 1. Remove filter if provided 2. Do not

Summary of the content on the page No. 17

CAUTION Operating Instructions GASES THAT ARE DRIVEN FROM FRESH FUEL, Model 1300 COAL MUST BE BURNED OR THEY WILL Egg size (1-3/16" or larger) bituminous coal ACCUMULATE AND EXPLODE. NEVER SMOTHER A FIRE WHEN ADDING FRESH for residential furnaces, or any of the specially COAL. packed fireplace coals can be used. Coal with a low ash content (2% to 6%) is recommended. FUEL, Model 1400 CAUTION Hardwood, 18" to 26" should be split and air dried DO NOT OPERATE WITH THE FEED AND/OR (seasoned) for 6

Summary of the content on the page No. 18

Service Hints If the chimney is operating too cool, water Do not expect a furnace to draw. It is the 4. chimney that creates the draft. Smoke spillage will condense in the chimney and run back into the furnace. Creosote formation will be into the house or excessive buildup of water or rapid and may block the chimney. Operate creosote in the chimney are warnings that the chimney is not functioning properly. Correct the the furnace at a high enough fire to keep the chimney warm, preventing th

Summary of the content on the page No. 19

13 27 14a 12 29 15 28 16 7 33 24 26 6 8 5 3 9 30 25 4 30 34 23 2 32 Model 1300 Repair Parts 11 10 19 35 1 20 17 18 22 21 31 14 14b 14c 37 38 36 19

Summary of the content on the page No. 20

PARTS LIST MODEL 1300 (SEE DIAGRAM, PAGE 19) KEY PART # DESCRIPTION QTY. 1 22684 CABINET LEFT SIDE 1 2 22682 CABINET BACK PANEL 1 22762 3 FORCED DRAFT RING 1 4 88032 FLUE COLLAR GASKET 1 5 40246 FLUE COLLAR 1 6 22761 FLUE COLLAR RING 1 83227 N/S BOLT (1/4-20 X 1) 6 83250 N/S KEP NUT (1/4-20) 6 7 22683 CABINET TOP PANEL 1 8 22685 CABINET RIGHT SIDE 1 9 22662 FEED DOOR HINGE BRACKET 1 23800 10 SMOKE CURTAIN 1 83337 N/S BOLT (5/16-18 X 1) 2 N/S 83338 LOCKNUT (5/16-18) 2 11 68218 ASH DOOR ASSEMBLY 1


Alternative user manuals
# User manual Category Download
1 United States Stove HOTBLAST 1400 User manual Cell Phone 9
2 Sony HBH-60 User manual Cell Phone 11
3 Sony 1261-4180 User manual Cell Phone 1
4 Sony 1264-0776 User manual Cell Phone 2
5 Sony 1265-9043 User manual Cell Phone 0
6 Sony Mobile Xperia tipo 1264-0772 User manual Cell Phone 0
7 Sony 1266-9650 User manual Cell Phone 0
8 Sony 1265-9044 User manual Cell Phone 0