Belshaw Brothers 724CG user manual

User manual for the device Belshaw Brothers 724CG

Device: Belshaw Brothers 724CG
Category: Fryer
Manufacturer: Belshaw Brothers
Size: 0.42 MB
Added : 4/25/2014
Number of pages: 42
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Belshaw Brothers 724CG. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Belshaw Brothers 724CG.

For your convenience

If looking through the Belshaw Brothers 724CG user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Belshaw Brothers 724CG on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Belshaw Brothers 724CG to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Belshaw Brothers 724CG User manual - Online PDF
Advertisement
« Page 1 of 42 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Belshaw Brothers 724CG but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Belshaw Brothers 724CG. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


Operator’s
Manual




Serial # W 06060001 - on




If you accept the machine from the shipping
Gas
company, you are, in effect, saying that the
machine is in good condition, and you must
pay for the machine. Belshaw cannot pay for
shipping damage, because the freight company
has accepted the machine from Belshaw in good
condition, and is responsible for its safe delivery.
Fryer
For your protec

Summary of the content on the page No. 2

EQUIPMENT RECORD Please provide the information below when you correspond with us about your machine. Purchased by _____________________________________________________________________ Installed by ______________________________________________________________________ Date of Installation ________________________________________________________________ Model number ____________________________________________________________________ Serial number 0606 MN-1141EN Belshaw Bros., Inc

Summary of the content on the page No. 3

Contents Sections 1 Installation 1 Conforming to Codes 1 Selecting a Workstation 1 Unpacking the Fryer 2 Initial Cleaning 2 Assembling the Fryer 2 Installing the Fryer 3 Moving the Fryer 4 2 Operation 5 Taking Safety Precautions 5 Frying Donuts 5 3 Cleaning 8 Removing the Shortening 8 Washing 9 Rinsing 10 4 Maintenance 11 5 Troubleshooting 17 Appendixes A Pilot Module A-1 Checkout A-1 Troubleshooting—General A-4 Troubleshooting the Ignition System A-4 nd Belshaw

Summary of the content on the page No. 4

B Donut-Making Helps B-1 Tips on Making Quality Cake Donuts B-1 Calculating Correct Water Temperature B-2 Ratios of Plunger Sizes to Donut Weights B-2 Temperature Conversion B-2 C Parts Lists C-1 Limited Warranty Insert

Summary of the content on the page No. 5

Preface The 718LCG, 724CG, and 734CG Gas Fryers are • To avoid damaging the machine, never designed to fry cake and yeast-raised donut use force to assemble, disassemble, products. Each must be bolted to a flat, dry operate, clean, or maintain it. floor. The operator should stand opposite the • Be careful never to get shortening, flue stack. water, or other materials on the floor. If The operator must work safely at all times and anything does get spilled on the floor, read this

Summary of the content on the page No. 6

Contact Belshaw Brothers at 1-800-578- 2547 to obtain necessary parts and instructions.

Summary of the content on the page No. 7

1 Installation In a prominent location, post instructions to be • The fryer must be isolated from the gas followed in the event the user smells gas. Obtain supply piping system by closing its this information by consulting your local gas individual manual shutoff valve during any supplier. pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.45 kPa). FOR YOUR SAFETY The fryer, when installed, must be electrically Do not store or us

Summary of the content on the page No. 8

The workstation should allow at least 2”/5 cm Assembling the Fryer clearance between the machine and all 1. Install the flue stack as follows: construction, whether combustible or noncombustible. In addition, it should allow a. Slide the flange on the bottom of the flue access to the rear of the fryer for cleaning and stack underneath the retaining strip on servicing. the flue base. The mounting holes must line up. (See Figure 1-1.) Unpacking the Fryer b. Fasten the flue stack

Summary of the content on the page No. 9

3. Put the heat shield and splash shield on the 4. Level the fryer. Follow these steps: fryer. They slide over the flue stack, and the a. Check to see if the fryer is level. To do back of the kettle slides between the heat so, place a level across the top of the shield and the splash shield. The mounting fryer cabinet. holes in the heat shield and the fryer cabinet b. If the fryer is not level, lift the fryer must line up. See Figure 1-2. using a fork lift or pallet jack, and tu

Summary of the content on the page No. 10

gas supply line on the fryer itself is Moving the Fryer 1/2”/1.3 cm I.P.S.) If you ever want to move the fryer to a different b. Connect the fryer to the building’s gas workstation, follow this procedure: supply. 1. Turn off the fryer and disconnect it from the c. Seal all threaded joints between gas power source. pipes with pipe joint compound. You 2. Disconnect the machine from the gas supply. must use a compound that resists the action of liquefied petroleum (LP) gases. 3. Al

Summary of the content on the page No. 11

Operation 2 proofer or feed table manual for complete Taking Safety Precautions installation and operation instructions. In a prominent location, post information about 2. Make sure the drain valve is closed. what to do if there is a gas leak. Make sure that 3. Put enough shortening in the kettle to all employees know what to do. completely cover the burner tubes, thermocouple, and high-temperature limit WARNING control probe. Put shortening in the kettle using one of To avoi

Summary of the content on the page No. 12

4. Move the on/off switch to the OFF position. Use one of the following methods. For safety reasons, we recommend the first 5. Rotate the gas control knob counterclock- method, and discourage you from using any wise to the ON position. other method. 6. Move the on/off switch to the ON position. • Use a Belshaw Shortening Melter (FM) The yellow pilot light near the on/off switch to melt shortening and transfer it to the and the red pilot light on the fryer cabinet kettle. See the F

Summary of the content on the page No. 13

CAUTION To avoid damaging the machine, do not operate the conveyor until all the shortening has melted. 11. Continue supplying shortening to the kettle as required. Keep the kettle filled up to the “Oil Level” marks on the side. 12. When you are done frying donuts, move the on/off switch to the OFF position. nd Belshaw Bros., Inc. • 1750 22 Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 7

Summary of the content on the page No. 14

3 Cleaning For your safety, observe the following warnings Removing the Shortening throughout the entire cleaning process. WARNING WARNING To avoid being burned or electrocuted, Thoroughly clean and dry the floor if disconnect the fryer from the power source shortening, water, or other materials are before cleaning it. spilled. Materials spilled on the floor can cause serious injury or loss of life. 1. Disconnect the machine from the power source. 2. Let the shortening cool

Summary of the content on the page No. 15

2. Connect the fryer to the power source. WARNING Move the on/off switch to ON. Set the temperature control to 200 °F/93 °C. Keep Do not allow the shortening to overflow the the cleaning solution at this temperature for containers. Shortening will get on the 15-20 minutes. floor, and if the shortening is not cool 3. Scrub the soiled parts while the solution is enough, you may be burned. hot. Do not use any abrasive cleaners or scrapers. WARNING WARNING Thoroughly clean an

Summary of the content on the page No. 16

WARNING WARNING Do not allow the cleaning solution to Do not use plastic containers. If the water overflow the containers. Cleaning solution is not cool enough, the containers will melt; will get on the floor, and if the solution is possibly causing you to be burned, and not cool enough, you may be burned. causing cleaning solution to get on the floor. 8. When the draining is complete, close the drain valve. 5. Open the drain valve and allow the water to drain into the container. 9.

Summary of the content on the page No. 17

Maintenance 4 SB-0308 rev 3 AFFECTS: OPEN KETTLE FRYERS PURPOSE: PROGRAMMING THE OGDEN ETR-9000 TEMPERATURE CONTROLLER NOTE: Use Rev. 3 to correct existing open Kettle Fryer settings. (SP1L set to 0 & PB set to 0) Operator Interface: The operator interface on the Ogden ETR-9000, Temperature Controller, consists of the following: • A scroll key used to select a parameter to be viewed or adjusted. • Up and down arrow keys are used to increase or decrease the selected parame

Summary of the content on the page No. 18

Menu Overview: There are three main menus that contain parameters that require programming; they are User Menu, Setup Menu, and Calibration Mode. The figure below (Figure 2) shows the sequence of operations necessary to access the programming parameters in each menu. Figure 2 - Menu Flow Chart nd Belshaw Bros., Inc. • 1750 22 Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 12 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers

Summary of the content on the page No. 19

Open Kettle Fryer Parameter Settings Tables 1, 2 and 3 below list of the temperature controller default settings and the Belshaw Factory settings. When installing a new controller 4 of the default setting must be changed to the Belshaw Factory settings. • Push and hold the scroll key for 3 seconds, this will take you to the “SEt” menu. • Push the scroll key once to access the “LocK” parameter. • Push the Up or down arrow keys to change “LocK” to “nonE”. • Push the scroll key to pa

Summary of the content on the page No. 20

Table 1 - Parameter Descriptions Set to 375ºF set to “uSEr” after setup 0ºF 410ºF 0ºF nd Belshaw Bros., Inc. • 1750 22 Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 14 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers


Alternative user manuals
# User manual Category Download
1 Belshaw Brothers 618L User manual Fryer 4
2 Belshaw Brothers 634 User manual Fryer 0
3 Belshaw Brothers 616BT User manual Fryer 1
4 Belshaw Brothers 624 User manual Fryer 3
5 Belshaw Brothers 718LCG User manual Fryer 1
6 Belshaw Brothers and 734CG User manual Fryer 0
7 Belshaw Brothers 616B User manual Fryer 1
8 Alto-Shaam Inc.ASF-75E User manual Fryer 1
9 Alto-Shaam FRY TECH ASF-75E User manual Fryer 1
10 Alto-Shaam Inc.Gas User manual Fryer 1
11 Alto-Shaam FRY TECH ASF-60E User manual Fryer 5
12 Alto-Shaam FRYTECH ASF-60G User manual Fryer 6
13 Alto-Shaam Fry Tech ASF-75DS User manual Fryer 1
14 Alto-Shaam Inc.Electric User manual Fryer 0
15 APW Wyott GF-15H User manual Fryer 1