Siemens C35i user manual

User manual for the device Siemens C35i

Device: Siemens C35i
Category: Cell Phone
Manufacturer: Siemens
Size: 0.13 MB
Added : 7/15/2014
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Siemens C35i. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Siemens C35i.

For your convenience

If looking through the Siemens C35i user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Siemens C35i on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Siemens C35i to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Siemens C35i User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Siemens C35i but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Siemens C35i. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1




GSM REMOTE SUPERVISION



GB 051 Set for cellular phone Siemens C35i, M35 or S35
Automatic Information Transfer over the GSM Network












USER GUIDE



LEVEL

Summary of the content on the page No. 2

Dear Customers, We would like to congratulate you on purchasing our product – GSM Remote Supervision GB 051. This way you are getting a high-class and technically highly modern product. GSM Remote Supervision GB 051 allows first-class and highly effective protection of cars or properties. It provides protection which cannot be easily disabled by cutting the phone line, protection which sends an ALARM message within 3 seconds and which allows also continuous control of protected area

Summary of the content on the page No. 3

TABLE OF CONTENTS – GSM Remote Supervision GB 051 1. Product Description................................ ................................ ........................ 4 1.2. Contents of Delivery ................................ ................................ ............... 5 2. Safety Commands ................................ ................................ ......................... 5 3. Installation and Setting into Operation................................ ............................ 6

Summary of the content on the page No. 4

1. Product Description 1.1. Description of Function GSM Remote Supervision GB 051 consists of plastic box, which is firmly joined to the battery of cell phone. Communication cable with connector gets out of this box into cell phone, which is used by GB 051 for realization of phone connection and reception and sending of SMS messages. On the upper side of the box there is a cut-off terminal board with terminals for power supply, for interface to PC, control inputs and 8 input/output

Summary of the content on the page No. 5

1.2. Contents of Delivery Sets Label Component description GB 051 010 GSM Remote Control only ● ● GB 051 011 GSM Remote Control with the Siemens C35i mobile phone ● ● SA 012 602 AC/DC Adapter 220 V / 12 V DC, 600 mA, cable 1,5 m long ● ● Connector ● ● ● ● 13 004 027 Siemens C35i mobile phone only ○ ○ External FME antenna reduction cable for the 13 004 028 ○ ○ ○ ○ Siemens C35i mobile phone ED 001 001 External 3 dB antenna with magnet, 3 meter cable ○ ○ ○ ○ ED 001 002 Fl

Summary of the content on the page No. 6

The GB 051 unit must be stocked always with the mobile phone connector disconnected – when disconnected from external power supply, the GB 051 is supplied from the mobile phone battery and the battery can be damaged by getting ! completely flat. 3. Installation and Setting into Operation 3.1. Assembly of GSM Remote Supervision GSM Remote Supervision by LEVEL is designed for operation in dry places. During assembly avoid hot places and places where device would be exposed to dire

Summary of the content on the page No. 7

RESET By connection clips no. 2 and 3 (ground and reset) the unit reset will be run, while all the set configuration value will remain in place. The value of days in service will be set to 0. INIT Detailed description of how to carry on the initialization can be found in Chapter 4.1. The GSM Remote Control device will be set into default manufacturer’s settings by the initialization. Recommended linkage of outputs: Recommended linkage of inputs: If GSM signal is insuf

Summary of the content on the page No. 8

Cell phone must be in basic configuration, only parameters specified further can be changed. A SIM card inserted in the GB 051 device must be configured in one of the two ways described below: a) If SIM is not blocked by PIN code, then the PIN value in GB 051 is irrelevant – in this case you can skip this instruction and continue to assembly the GB 051 and the cell phone. b) If SIM is blocked by PIN, and then the PIN in GB 051 must be the same with the PIN at the SIM in mobile phone

Summary of the content on the page No. 9

If the PIN code on the SIM card is the same as the PIN in GB 051 and SIM is blocked by PIN, then after setting new PIN to the GB 051 unit the PIN will be changed in both – the SIM and GB 051 unit. GB 051 replies to this SMS message and draws sender’s attention to necessity of unification of PIN in Remote Supervision and phone and to necessity of switch-off of cell phone. After reception of this SMS message verify correct PIN code change by switching the phone off with the red phone bu

Summary of the content on the page No. 10

Send a control SMS message from cell phone or Internet, which includes in text: XXppppINSTRUCTIONVparameter XX Two capital letters X pppp Four digits of current PIN in GSM Remote Supervision INSTRUCTION Key word of the command (no difference with capital or small letters) V Space follows parameter Set-up value* End of sequence by space or end of SMS message One SMS can include up to 4 commands. The message then can look like this: XXppppCOMMAND1Vparameter1VCOMMAND2Vparameter2VC

Summary of the content on the page No. 11

Value of PIN of GSM gate set from production and after initialization is 0000. PIN 0000 shall not be set into cell phone from gate so that blockage of phone is not caused during first contacts with gate. Example: Original PIN of GSM gate is 0000. SIM card, which you use in cell phone in GSM gate has PIN 1234 and is blocked by PIN. Insert the SIM card into the mobile phone, but do not connect the GB 051 connector yet. Insert the required PIN in the mobile phone (e.g. 1234). Go into t

Summary of the content on the page No. 12

4.3. INIT – Re-initialization of Values Set from Production In case you lost view of GB 051 set-up you can carry out remote re-initialization of parameter values set in production. Command XXppppINIT Pppp Four digits of current PIN GSM Remote Supervision will be set to initial set-up from production. Sender of Command receives message about correct reception of Command. In case you do not know pre-set PIN or you are not able to program for another reason then carry out hardw

Summary of the content on the page No. 13

*1) Command XXppppMCALLVnumber Pppp Four digits of current PIN *2) Number Maximum 14 digits of number of any phone *1) The space is between key word of command „MCALL“ and value of parameter „h“ *2) Number can be entered in national format – e.g. 606445566 but also in international format – e.g. +420606445566. No number is activated from production. After entering this parameter GB 051 calls set number once a month in order to spend at least one tariff impulse. If you want to

Summary of the content on the page No. 14

If you want to deactivate this function set command without parameter – tm. XXppppINFOSMS without further parameters. 4.8. SMSINT – Interval for Dispatch of SMS Messages about Operation Interval for sending regular SMS messages to INFOSMS number, which include time of operation, can be set: Command XXppppSMSINTVn (interval of one day is set from production) *1) pppp Four digits of current PIN Number Number from 1 to 30. It is interval for sending successive message about operat

Summary of the content on the page No. 15

Activated by input Order on the *1) Command No.: terminal board XXppppSMSNOA1Vnumber IO1 1 XXppppSMSNOB1Vnumber IO1 1 XXppppSMSNOA2Vnumber IO2 2 XXppppSMSNOB2Vnumber IO2 2 XXppppSMSNOA3Vnumber IO3 3 XXppppSMSNOB3Vnumber IO3 3 XXppppSMSNOA4Vnumber IO4 4 XXppppSMSNOB4Vnumber IO4 4 XXppppSMSNOA5Vnumber IO5 5 XXppppSMSNOB5Vnumber IO5 5 XXppppSMSNOA6Vnumber IO6 6 XXppppSMSNOB6Vnumber IO6 6 XXppppSMSNOB7Vnumber IO7 8 XXppppSMSNOB7Vnumber IO7 8 XXppppSMSNOB8Vnumber IO8 9 XXppppSMSN

Summary of the content on the page No. 16

If you only want to change value of output regardless of previous state send command without parameter “y” – e.g. XXppppOUT5 changes value of output No. 5 to reverse. Newly set actual values of all 8 inputs/outputs are sent back to sender and to INFOSMS number. 4.11. LIST – Detection of Set-up If you want to find out which values of parameters are set in GB 051 it is possible to send control SMS message, which initiates sending messages with detailed description of set-up back to

Summary of the content on the page No. 17

The call will take 255 seconds unless you end it sooner by hang-up. Sensitivity of cell phone built-in microphone might be relatively low. Therefore it is necessary to select a suitable placement of the unit in order to use this feature. 5. Programming from PC Comfortable way of setting of all GB 051 parameters from PC by the means of configuration program and serial cable with converter can be used. Program and cable can be bought additionally as set for configuration from PC –

Summary of the content on the page No. 18

7. List of Programming Commands – Control SMS Messages Command XXpppp Description Range Set *1) Set PIN PINVnnnn nnnn 4 digits of PIN 0000 RESET of GSM Supervision RESET – – Initialisation of parameters INIT – – Regular information calling ICALLVn n= max. 14 digits – Length of interval of calling ICALLINTVh h= 1–240 (hours) 168 Monthly calling MCALLVn n= max. 14 digits – Alarm calling ACALLiVn n= max. 14 digits – Information number INFOSMSVn n= max. 14 digits – Interval of sen

Summary of the content on the page No. 19

8. Basic Technical Parameters GB 051 ALARM tone 400 Hz Inputs of SMS messages No. 1–8 Logical 0 0–0,5 V Logical 1 4–6 V Outputs of SMS messages No. 1–8 Logical 0 max. 0,8 V for Iz= 5 mA Logical 1 3,5–4,5 V for Iz= 0,03 mA GSM network GSM 900/1800 MHz SIM card Plug-in Device Power supply voltage 10–16 V DC Peak power consumption during charging 350 mA (for 12 V) Max. time of charging 4 hours Power consumption with charged battery < 20 mA Time of operation from back

Summary of the content on the page No. 20

GUARANTEE CERTIFICATE Product name: ..........…....................... Type: …….....…………....................……….. Production number: .…...................…. Date of sale: .............…………........……….. Signature: …………….............………. Seller (stamp): ……………………………….. Information about guarantee repairs: Date of Date of Signature Description of defect receipt return Producer: LEVEL ltd.,


Alternative user manuals
# User manual Category Download
1 Siemens 4000i User manual Cell Phone 60
2 Siemens A35 User manual Cell Phone 27
3 Siemens C60 User manual Cell Phone 113
4 Siemens CFX65 User manual Cell Phone 15
5 Siemens 8WD44 User manual Cell Phone 17
6 Siemens Gigaset C450 IP User manual Cell Phone 164
7 Siemens CXT65 User manual Cell Phone 2
8 Siemens A57 User manual Cell Phone 94
9 Siemens Gigaset 4110 User manual Cell Phone 54
10 Siemens A55 User manual Cell Phone 118
11 Siemens BE INSPIRED S56 User manual Cell Phone 4
12 Siemens Gigaset 200 User manual Cell Phone 544
13 Siemens Gigaset S450 IP User manual Cell Phone 285
14 Siemens C56 User manual Cell Phone 11
15 Siemens AX75 User manual Cell Phone 11
16 Sony HBH-60 User manual Cell Phone 11
17 Sony 1261-4180 User manual Cell Phone 1
18 Sony 1264-0776 User manual Cell Phone 2
19 Sony 1265-9043 User manual Cell Phone 0
20 Sony Mobile Xperia tipo 1264-0772 User manual Cell Phone 0