Goodman Mfg . Co. LP.ACVC9/AMVC95 user manual

User manual for the device Goodman Mfg . Co. LP.ACVC9/AMVC95

Device: Goodman Mfg . Co. LP.ACVC9/AMVC95
Category: Furnace
Manufacturer: Goodman Mfg
Size: 0.55 MB
Added : 8/17/2014
Number of pages: 37
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Goodman Mfg . Co. LP.ACVC9/AMVC95. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Goodman Mfg . Co. LP.ACVC9/AMVC95.

For your convenience

If looking through the Goodman Mfg . Co. LP.ACVC9/AMVC95 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Goodman Mfg . Co. LP.ACVC9/AMVC95 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Goodman Mfg . Co. LP.ACVC9/AMVC95 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Goodman Mfg . Co. LP.ACVC9/AMVC95 User manual - Online PDF
Advertisement
« Page 1 of 37 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Goodman Mfg . Co. LP.ACVC9/AMVC95 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Goodman Mfg . Co. LP.ACVC9/AMVC95. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

TECHNICAL MANU TECHNICAL MANU TECHNICAL MANUAL AL AL
TECHNICAL MANU TECHNICAL MANUAL AL
TM
ACVC9/AMVC95
GCVC9/GMVC95
90%-95% Gas Furnace Units
• Refer to Service Manual RS6200004 for installation, operation, and troubleshooting information.
• All safety information must be followed as provided in the Service Manual.
• Refer to the appropriate Parts Catalog for part number information.
• Models listed on page 3.
®
C US

RT6612021 Rev. 3
This manual is to be used by qualified, professionally trai

Summary of the content on the page No. 2

PRODUCT IDENTIFICATION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. GC V C 9 070 4 C X A A PRODUCT AFUE ADDITIONAL TYPE: FEATURES: MINOR 9: 90% G: Goodman® REVISION 95: 95% N: Natural Gas A: Amana® X: Low NOx LEVEL Brand Gas A: Initial Release COMMUNICATION CABINET SUPPLY TYPE: FEATURE: WIDTH: MAJOR C: Counterflow/

Summary of the content on the page No. 3

PRODUCT IDENTIFICATION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. GMVC950453BXAA AMVC950453BXAA GMVC950704CXAA AMVC950704CXAA GMVC950905CXAA AMVC950905CXAA GMVC950905DXAA AMVC950905DXAA GMVC951155DXAA AMVC951155DXAA GCVC90704CXAA ACVC90704CXAA GCVC90905DXAA ACVC90905DXAA GCVC91155DXAA AMVC950453BXAB GMVC950453BXAB AMVC950704CXAB GMVC950704CXAB AMVC950905D

Summary of the content on the page No. 4

SIDE PRODUCT DESIGN installation (1 or 2 pipes). The optional Combustion Air General Operation Pipe is dependent on installation/code requirements and Models covered by this manual come with a new 4-wire com- must be 2” or 3” diameter PVC. municating PCB. When paired with a compatible communi- cating indoor unit and a CTK01AA communicating thermo- 2. Line voltage wiring can enter through the right or left side stat, these models can support 4-wire communication pro- of the furnace. Low voltage

Summary of the content on the page No. 5

PRODUCT DESIGN quired due to the natural reduction in the density of both the of time before stepping up to high stage to satisfy the gas fuel and combustion air as altitude increases. The kit thermostat’s call for heat. The delay period prior to stepping will provide the proper design certified input rate within the up can be set at either a fixed 5 minute time delay or a load specified altitude range. based variable time between 1 and 12 minutes (AUTO mode). If the AUTOmode is selected, the c

Summary of the content on the page No. 6

COMPONENT IDENTIFICATION 23 6 10 5 8 9 26 5 27 7 7 10 32 11 4 11 25 3 3 12 2 24 28 13 1 15 14 31 3 17 16 3 15 18 14 18 31 17 19 19 29 20 16 20 30 18 21 18 19 19 20 28 20 13 12 2 21 25 1 26 9 6 8 4 23 27 7 7 Upflow/Horizontal Counterflow /Horizontal 1 Two-Stage Gas Valve 18 Coil Front Cover Pressure Tap 2 Gas Line Entrance (Alternate) 19 Coil Front Cover Drain Port 3 Pressure Switch(es) 20 Drain Line Penetrations 4 Gas Manifold 21 Drain Trap 5 Combustion Air Intake Connection 22 Blower Door Inter

Summary of the content on the page No. 7

PRODUCT DIMENSIONS GMVC95/AMVC95___X* 7 AIR DISCHARGE A AIR B DISCHARGE (DISCHARGE AIR) 19 3/4 VENT/FLUE PIPE 2" PVC C AIR INTAKE PIPE 2" PVC 2 11/16 STANDARD GAS CONDENSATE SUPPLY HOLE DRAIN TRAP w/ 3/4" PVC DISCHARGE (RIGHT OR LEFT SIDE) DRAIN 4 1/8 LEFT SIDE 2 5/8 TRAP 30 1/4 DRAIN LINE RIGHT SIDE HOLES DRAIN LINE HOLES DRAIN TRAP LOW VOLTAGE 19 3/16 LOW VOLTAGE ELECTRICAL HOLE 19 3/16 ELECTRICAL HOLE HIGH VOLTAGE ELECTRICAL HOLE 2 HIGH VOLTAGE ELECTRICAL HOLE 11 3/4 1 3/4 32 13/16 SIDE CU

Summary of the content on the page No. 8

PRODUCT DIMENSIONS GCVC9/ACVC9_____X* 8 A B VENT/FLUE PIPE (RETURN AIR) 2" PVC AIR INTAKE C PIPE 2" PVC CONDENSATE DRAIN TRAP LOW VOLTAGE 1 3/4 w/ 3/4" PVC ELECTRICAL HOLE 1 3/4 DISCHARGE LOW VOLTAGE (RIGHT OR HIGH VOLTAGE ELECTRICAL HOLE LEFT SIDE) ELECTRICAL HOLE 28 5/16 28 5/16 HIGH VOLTAGE ELECTRICAL HOLE 2 11/16 DRAIN DRAIN TRAP TRAP 2 5/8 18 13/16 RIGHT SIDE LEFT SIDE 15 1/2 DRAIN LINE DRAIN LINE 14 HOLES HOLES 11 1/2 2 7 3/8 ALTERNATE GAS STANDARD GAS 9 13/16 SUPPLY HOLE SUPPLY HOLE 18

Summary of the content on the page No. 9

PRODUCT DESIGN PRESSURE SWITCH TRIP POINTS AND USAGE CHART NEGATIVE PRESSURE NEGATIVE PRESSURE NEGATIVE PRESSURE NEGATIVE PRESSURE ID BLOWER ID BLOWER COIL COVER COIL COVER WITH FLUE WITH FLUE WITH FLUE WITH FLUE NOT FIRING FIRING NOT FIRING FIRING MODEL TYPICAL SEA LEVEL TYPICAL SEA LEVEL TYPICAL SEA LEVEL TYPICAL SEA LEVEL (1) (2) (1) (2) DATA DATA DATA DATA LOW FIRE HIGH FIRE LOW FIRE HIGH FIRE LOW FIRE HIGH FIRE LOW FIRE HIGH FIRE GMVC950453BX* GMVC950704CX* -0.45 -0.90 -0.50 -0.95 -0.25 -0

Summary of the content on the page No. 10

PRODUCT DESIGN 10 PRESSURE SWITCH TRIP POINTS AND USAGE CHART 0 to 7,000 ft. 7,001 ft. to 11,000 ft. TRIP POINT TRIP POINT TRIP POINT TRIP POINT COIL COVER COIL COVER ID BLOWER ID BLOWER COIL COVER ID BLOWER HIGH MODEL PRESSURE SWITCH PRESSURE PRESSURE SWITCH PRESSURE PRESSURE SWITCH PRESSURE SWITCH ALTITUDE SWITCH SWITCH KIT PART # PART # LOW FIRE HIGH FIRE LOW FIRE HIGH FIRE LOW FIRE HIGH FIRE LOW FIRE HIGH FIRE GMVC950453BX* GMVC950704CX* HAPS28 -0.10 -0.10 20197308 -0.30 -0.75 11177113 -

Summary of the content on the page No. 11

PRODUCT DESIGN PRIMARY LIMIT Part Number 20162903 20162904 20162905 20162907 20162908 0130F00105 Open Setting (°F) 160 150 145 155 170 130 GMVC950453BX* --- --- 1 --- --- --- AMVC950453BX* GMVC950704CX* --- --- --- 1 --- --- AMVC950704CX* GMVC950905CX* --- --- --- --- --- 1 AMVC950905CX* GMVC950905DX* --- --- 1 --- --- --- AMVC950905DX* GMVC951155DX* --- 1 --- --- --- --- AMVC951155DX* GCVC90704CX* 1 --- --- --- --- --- ACVC90704CX* GCVC950714CX* --- 1 --- --- --- --- ACVC950714CX* GCVC90905DX*

Summary of the content on the page No. 12

PRODUCT DESIGN AUXILIARY LIMIT SWITCHES Part Number 10123534 10123535 10123537 10123536 10123533 0130F00038 220 150 190 180 200 120 Open Setting (°F) GMVC950453BX* --- 2 --- --- --- --- AMVC950453BX* GMVC950704CX* ------ 2 --- ------ AMVC950704CX* GMVC950905CX* --- --- --- --- --- 2 AMVC950905CX* GMVC950905DX* --- --- --- 2 --- --- AMVC950905DX* GMVC951155DX* --- --- --- --- 2--- AMVC951155DX* GCVC90704CX* 2 --- --- --- --- --- ACVC90704CX* GCVC950714CX* --- --- --- --- --- 2 ACVC950714CX* GC

Summary of the content on the page No. 13

PRODUCT DESIGN Coil Matches: A large array of Amana® brand coils are available for use with the GCVC9 and ACVC9 furnaces, in either counterflow or horizontal applications & with GMVC95 and AMVC95 furnaces, in either upflow or horizontal applications. These coils are available in both cased and uncased models (with the option of a field installed TXV expansion device). These 92%+ and 95%+ furnaces match up with the existing Amana® brand coils as shown in the chart below. ® ® Coil Matches (for Go

Summary of the content on the page No. 14

PRODUCT DESIGN Thermostats: ComfortNet™ CTK01A* Thermostat Kit Filters: Filters are required with this furnace and must be provided by the installer. The filters used must comply with UL900 or CAN/ULCS111 standards. Installing this furnace without filters will void the unit warranty Upflow Filters Return air filters may be installated at the furnace side and/or bottom return openings. The furnace bottom return opening and side openings will accommodate the following filter sizes depending on cab

Summary of the content on the page No. 15

PRODUCT DESIGN UPFLOW COOLING AIRFLOW REQUIREMENT (CFM) 600 800 1000 1200 1400 1600 1800 2000 0453__X* 207* 207* 240 288 --- --- --- --- 0704__X* --- --- 318* 318* 336 384 --- --- 0905__X* --- --- --- 413* 413* 413* 432 480 1155__X* --- --- --- 437* 437* 437* 432 480 COUNTERFLOW COOLING AIRFLOW REQUIREMENT (CFM) 600 800 1000 1200 1400 1600 1800 2000 0704__X* --- --- 316* 316* 336 384 --- --- 0714__X* 0905__X* --- --- --- 409* 409* 409* 432 480 0915__X* 1155__X* --- --- --- 430* 430* 430* 432 480

Summary of the content on the page No. 16

FURNACE SPECIFICATIONS GMVC95 GMVC950453BX* GMVC950704CX* GMVC950905CX* GMVC950905DX* GMVC951155DX* MODEL Btuh Input (US) High Fire 46,000 69,000 92,000 92,000 115,000 Output (US) High Fire 44,300 66,900 88,800 88,800 111,100 Btuh Input (US) Low Fire 32,000 48,000 64,000 64,000 80,000 Output (US) Low Fire 30,800 46,400 61,700 61,700 77,400 A.F.U.E. 95% 95% 95% 95% 95% Rated External Static (" w.c.) .10 - .50 .10 - .50 .10 - .50 .10 - .50 .10 - .50 Temperature Rise (°F) 30 - 60 30

Summary of the content on the page No. 17

FURNACE SPECIFICATIONS AMVC95 AMVC950453BX* AMVC950704CX* AMVC950905CX* AMVC950905DX* AMVC951155DX* MODEL Btuh Input (US) High Fire 46,000 69,000 92,000 92,000 115,000 Output (US) High Fire 44,300 66,900 88,800 88,800 111,100 Btuh Input (US) Low Fire 32,000 48,000 64,000 64,000 80,000 Output (US) Low Fire 30,800 46,400 61,700 61,700 77,400 A.F.U.E. 99% 95.5% 95.7% 95.7% 95.8% Rated External Static (" w.c.) .10 - .50 .10 - .50 .10 - .50 .10 - .50 .10 - .50 Temperature Rise (°F) 30

Summary of the content on the page No. 18

FURNACE SPECIFICATIONS GCVC9 GCVC90704CX* GCVC90905DX* GCVC91155DX* MODEL Btuh Input (US) High Fire 69,000 92,000 115,000 Output (US) High Fire 65,300 86,500 109,000 Btuh Input (US) Low Fire 48,000 64,000 80,000 Output (US) Low Fire 45,000 60,100 77,400 A.F.U.E. 93.0% 92.0% 93% Rated External Static (" w.c.) .10 - .50 .10 - .50 .10 - .50 Temperature Rise (°F) 30 - 60 30 - 60 40 - 70 High Stage Pressure Switch Trip Point (" w.c.) -0.55 -0.55 -0.55 Low Stage Pressure Switch Trip Poi

Summary of the content on the page No. 19

FURNACE SPECIFICATIONS GCVC95 GCVC950714CX* GCVC950915DX* MODEL Btuh Input (US) High Fire 69,000 92,000 Output (US) Hig h Fire 65,300 8 6,500 Btuh Input (US) Low Fire 48,000 64,000 Output (US) Lo w Fire 45,000 6 0,100 A.F.U.E. 95.0% 95.0% R ated Exte rnal Static (" w .c.) .1 0 - .50 .1 0 - .50 Te m perature R ise (°F) 2 5 - 55 2 5 - 55 H igh Stage Pressure Switch Trip Point (" w .c.) -1.60 -1.60 Low Stage Pressu re Switch T rip Po int (" w.c.) -0.80 -0.80 Front C over Pressure Swi

Summary of the content on the page No. 20

FURNACE SPECIFICATIONS ACVC9 ACVC90704CX* ACVC90905DX* MODEL Btuh Input (US) High Fire 69,000 92,000 Output (US) High Fire 65,300 86,500 Btuh Input (US) Low Fire 48,000 64,000 Output (US) Low Fire 45,000 60,100 A.F.U.E . 93.3% 92.7% Rated E xternal Static (" w.c.) .10 - .50 .10 - .50 Tem perature Rise (°F) 30 - 60 30 - 60 High S tage P ressure S witch Trip Point (" w.c.) -0.55 -0.55 Low Stage Pressure Switch Trip Point (" w.c.) -0.20 -0.20 Front Cover P ressure S witch Trip Point


Alternative user manuals
# User manual Category Download
1 Goodman Mfg ACVC90704CXAB User manual Furnace 0
2 Goodman Mfg ACVC950915DXAA User manual Furnace 1
3 Goodman Mfg ACVC90905DXAB User manual Furnace 0
4 Goodman Mfg ACVC90905DXAA User manual Furnace 0
5 Goodman Mfg CVC9/95 User manual Furnace 2
6 Goodman Mfg AMV8 User manual Furnace 0
7 Goodman Mfg GCVC90704CXAA User manual Furnace 0
8 Goodman Mfg GCVC91155DXAA User manual Furnace 2
9 Goodman Mfg GCH9 User manual Furnace 3
10 Goodman Mfg ACVC950714CXAA User manual Furnace 0
11 Goodman Mfg GCVC91155DXAB User manual Furnace 0
12 Goodman Mfg GCVC90704CXAB User manual Furnace 0
13 Goodman Mfg GCVC90905DXAB User manual Furnace 0
14 Goodman Mfg GCVC90905DXAA User manual Furnace 1
15 Goodman Mfg GDH80453AXCA User manual Furnace 0
16 Adams Condensing Oil-Fired User manual Furnace 2
17 AirComm Corporation 10016 User manual Furnace 0
18 AirComm Corporation 7516 User manual Furnace 0
19 AirComm Corporation 50 User manual Furnace 0
20 Air King 9320 User manual Furnace 2