Quadra-Fire QVI30S user manual

User manual for the device Quadra-Fire QVI30S

Device: Quadra-Fire QVI30S
Category: Furnace
Manufacturer: Quadra-Fire
Size: 3.86 MB
Added : 1/25/2014
Number of pages: 45
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Quadra-Fire QVI30S. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Quadra-Fire QVI30S.

For your convenience

If looking through the Quadra-Fire QVI30S user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Quadra-Fire QVI30S on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Quadra-Fire QVI30S to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Quadra-Fire QVI30S User manual - Online PDF
Advertisement
« Page 1 of 45 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Quadra-Fire QVI30S but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Quadra-Fire QVI30S. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

DO NOT
DISCARD
R
Owner’s Manual
Installation and Operation
Model(s):
QVI30S
QVI35S
CAUTION
DO NOT DISCARD THIS MANUAL
• Important operating • Read, understand and follow
• Leave this manual with
and maintenance these instructions for safe party responsible for use
instructions included. installation and operation. and operation.
WARNING
WARNING: If the information in these
HOT SURFACES!
instructions is not followed exactly, a fi re
Glass and other surfaces are hot during
or explosion may r

Summary of the content on the page No. 2

Read this manual before installing or operating this appliance. Please retain this owner’s manual for future reference. Congratulations Congratulations on selecting a Quadra-Fire gas appliance This Owner’s Manual should be retained for future —an elegant and clean alternative to wood burning reference. We suggest that you keep it with your other important documents and product manuals. appliances. The Quadra-Fire gas appliance you have selected is designed to provide the utmost in safety, T

Summary of the content on the page No. 3

Table of Contents 1 Listing and Code Approvals 8 Gas Information A. Appliance Certifi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 A. Fuel Conversions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 B. BTU Specifi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 B. Gas Pressures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 C. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . . 4 C. Ga

Summary of the content on the page No. 4

Listing and Code Approvals 1 1 A. Appliance Certifi cation C. High Altitude Installations U.L. Listed gas appliances are tested and approved with- MODELS: QVI30S, QVI35S out requiring changes for elevations from 0 to 2000 feet in the U.S.A. and Canada. LABORATORY: Underwriters Laboratories, Inc. (UL) When installing this appliance at an elevation above TYPE: Vented Gas Appliance Heaters 2000 feet, it may be necessary to decrease the input rat- STANDARD: ANSI Z21.88-2000 • CSA2.33-M00 • U

Summary of the content on the page No. 5

Getting Started 2 2 A. Design and Installation Considerations C. Inspect Appliance and Components Quadra-Fire direct vent gas appliances are designed to operate with all combustion air siphoned from outside of WARNING the building and all exhaust gases expelled to the outside. Inspect appliance and components for damage. No additional outside air source is required. Damaged parts may impair safe operation. • Do NOT install damaged components. CAUTION • Do NOT install incomplete component

Summary of the content on the page No. 6

Fireplace Size Requirements 3 3 • The metal fl oor of the solid fuel fi rebox may be removed to A. Minimum Fireplace Opening facilitate the installation of the insert. The appliance may Minimum fi replace opening requirements are shown in not be placed directly on the base of the outer wrap, a 1/4 Figure 5.1. inch airspace must be provided between the insert and WARNING! Risk of Fire or Burns! Provide adequate the fl oor of the outer wrap. Use the levelling legs to raise clearance aroun

Summary of the content on the page No. 7

B. Clearances WARNING Fire Risk. Odor Risk. • Clearance to combustible material under the insert is 1/4 inch (0.6 cm). • Use leveling legs to raise insert minimum 1/4 inch above combustible material or outer wrap of factory built fi rebox. WARNING Fire Risk. • Locate and install appliance to all clearance specifi cations in manual. INLET AIR 12 in. MAX. EXHAUST VENT PIPE VENT PIPE MANTEL 12 in. MIN. MEASUREMENTS FROM TOP EDGE OF UNIT Figure 3.2 Clearances to Mantels or other Combustibles abov

Summary of the content on the page No. 8

Termination Locations 4 4 A. Vent Termination Minimum Clearances Figure 4.1 specifi es minimum vent heights for various pitched roofs. HORIZONTAL OVERHANG 2 FT. 20 INCHES MIN. VERTICAL MIN. WALL LOWEST DISCHARGE OPENING GAS DIRECT VENT TERMINATION CAP X 12 ROOF PITCH IS X/ 12 H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 ...................................

Summary of the content on the page No. 9

Vent Information and Diagrams 5 5 A. Vent Table Key WARNING The abbreviations listed in this vent table key are used in the vent diagrams. Fire Hazard. Explosion Risk. Symbol Description Asphyxiation Risk. V Minimum Vertical Run Length 14 ft. Do NOT connect this gas appliance to a MIN chimney fl ue serving a separate solid fuel or V Maximum Vertical Run Length 50 ft. MIN gas burning appliance. • May impair safe operation of this appliance B. Horizontal Venting or other appliances connecte

Summary of the content on the page No. 10

Installation Preparation 6 6 Prepare the existing solid fuel masonry or factory built E. Fireplace Conversion Notice non-combustible fi rebox for installation. Permanently attach the label with the following warning to the inside lower back of the fi replace fi rebox into which A. Flue Damper the insert is being installed. Silicone may be required to Fully lock the solid fuel fi replace’s fl ue damper in the open properly secure the label. position, OR completely remove it. B. Chimney WARNIN

Summary of the content on the page No. 11

Installing Vent Pipe and Appliance 7 7 A. Venting Components B. Connecting Vent Pipe Reference instructions in the termination kit. CAUTION • Install the 3-inch fl exible vent pipe(s) down through the chimney. Sharp Edges • Use three screws to secure the exhaust fl exible vent • Wear protective gloves and safety pipe to the 3 foot section stainless steel fl exible vent pipe glasses during installation. using the factory-installed 3-inch collar in the stainless steel section of pipe (see Fi

Summary of the content on the page No. 12

CUT AND BEND WARNING FLASHING AS NEEDED TO FIT CHIMNEY Fire Risk. Only an approved Hearth & Home Technologies surround may be used to cover integral grills on solid fuel burning fi replaces. • No other components such as shrouds, sheet- SEALANT metal plates, etc., may be used to seal off vents. ADHESIVE WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifi cally approved with this appliance may result in property damage or personal injury

Summary of the content on the page No. 13

D. Installing Adaptor and Termination Cap CAUTION For installation of termination cap see minimum vent heights for various pitched roofs (see Figure 7.2) . Sharp Edges To install adaptor see Figure 7.3. • Wear protective gloves and safety glasses during installation. HORIZONTAL OVERHANG Damper Flashing Kit (Optional) For use with LINK-DV4-30B Liner Kit. 2 FT. 20 INCHES MIN. VERTICAL MIN. WALL Note: Damper may have to be removed to use this kit. LOWEST DISCHARGE OPENING • Run fl ex liners thro

Summary of the content on the page No. 14

Gas Information 8 8 A. Fuel Conversions C. Gas Connection Before making gas connections ensure that appliance be- Note: Have the gas supply line installed in accordance ing installed is compatible with the available gas type. with local building codes, if any. If not, follow ANSI Any natural or propane gas conversions necessary to 223.1. Installation should be done by a qualifi ed installer meet the appliance and locality needs must be made by approved and/or licensed as required by the

Summary of the content on the page No. 15

HIGH ALTITUDE INSTALLATIONS WARNING U.L. Listed gas appliances are tested and approved without Fire or Explosion Hazard requiring changes for elevations from 0 to 2000 feet in the • Gas buildup during line purge may ignite. U.S.A. and Canada. • Purge should be performed by qualifi ed technician. When installing this appliance at an elevation above 2000 feet, • Ensure adequate ventilation. it may be necessary to decrease the input rating by changing • Ensure there are no ignition sources such

Summary of the content on the page No. 16

Electrical Information 9 9 Appliance Requirements A. Wiring the Appliance • This appliance DOES NOT require 110-120 VAC to Note: Electrical wiring must be installed by a licensed operate. electrician. • It is recommended that a 110 VAC junction box be connected for use with fan or remote control. (See Figure Note: This appliance must be electrically wired and grounded 9.2 for junction box wiring). in accordance with local codes or, in the absence of local codes, with National Electric

Summary of the content on the page No. 17

B. Junction Box Installation JUNCTION BOX ACCESS SIDEWALL JUNCTION BOX SCREW PROVIDED Figure 9.2 Junction box installation Optional Accessories Connecting the electrical junction box is required if using a blower or remote. • Plug the cord into a convenient outlet. • An electrician may install an outlet box inside the fi replace. Place the outlet in the lower, back corner of the fi replace. • Must use cord supplied. CAUTION Label all wires prior to disconnection when servicing controls. Wi

Summary of the content on the page No. 18

VARIABLE SPEED CONTROL JUNCTION BOX BLK BLK BLOWER RECEPTACLE BLK BLK BLK BLK BLK WHT WHT BLK GROUND BLOWER TEMPERATURE GRN SENSOR SWITCH BLK WHT 110-120 VAC FAN JUNCTION BOX NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, TEMPERATURE SENSOR SWITCH IT MUST BE REPLACED WITH TYPE 0 105 C RATED WIRE. SPEED CONTROL (RHEOSTAT) BEND GROUND WIRE UP TABS (ATTACH TO ANY METAL SURFACE) Figure 9.4 Fan/Rheostat Wire Diagram Quadra-Fire • QVI30S, QVI35S • 340-901 R

Summary of the content on the page No. 19

Finishing 10 10 A. Mantel Projections Figure 10.1 shows the minimum vertical and corresponding maximum horizontal dimensions of appliance mantels or other combustible projections above the top front edge of the appliance, not the surround. INLET AIR 12 in. MAX. EXHAUST VENT PIPE VENT PIPE MANTEL 12 in. MIN. MEASUREMENTS FROM TOP EDGE OF UNIT Figure 10.1 Clearances to Mantels or other Combustibles above Appliance Quadra-Fire • QVI30S, QVI35S • 340-901 Rev. i • 6/09 19

Summary of the content on the page No. 20

Appliance Setup 1 11 1 A. Remove Shipping Materials Placing the Ember Material Ember material is shipped with this gas appliance. To place Remove shipping materials from inside or underneath the the ember material: fi rebox. • Embers CANNOT be placed directly over ports. B. Clean the Appliance • When placing Glowing Embers® onto the burner care Clean/vacuum any sawdust that may have accumulated should be taken so that the ports are not covered. Place inside the fi rebox or underneath in t


Alternative user manuals
# User manual Category Download
1 Quadra-Fire QVI35S User manual Furnace 0
2 Adams Condensing Oil-Fired User manual Furnace 2
3 AirComm Corporation 10016 User manual Furnace 0
4 AirComm Corporation 7516 User manual Furnace 0
5 AirComm Corporation 50 User manual Furnace 0
6 Air King 9320 User manual Furnace 2
7 Air King 9718 User manual Furnace 5
8 AirComm Corporation 7512 User manual Furnace 1
9 Allied Air Enterprises A80UH User manual Furnace 8
10 Allied Air Enterprises 92G1DF User manual Furnace 0
11 Allied Air Enterprises 95G1DF User manual Furnace 0
12 American Standard 32-5037-01 User manual Furnace 1
13 American Standard Condensing Gas s Fan Assisted Combustion System Upflow Horizontal and Downflow Horizontal User manual Furnace 0
14 American Standard Noncondensing Gas s User manual Furnace 1
15 Amana Gas Furnance GME8 User manual Furnace 0