Our goal is to provide you with a quick access to the content of the user manual for Bryant 383KAV. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bryant 383KAV.

For your convenience

If looking through the Bryant 383KAV user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bryant 383KAV on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bryant 383KAV to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bryant 383KAV User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bryant 383KAV but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bryant 383KAV. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


USER’S INFORMATION MANUAL
USER’S INFORMATION MANUAL
MODELS 373LAV, 376CAV
DOWNFLOW/HORIZONTAL and
383KAV, 395CAV UPFLOW GAS FURNACE
NOTE TO INSTALLER:
This manual must be left with the
equipment user.
!
WARNING: If the information in this man-
ual is not followed exactly, a fire or explosion may
result causing property damage, personal injury
or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
Upflow
other appliance.
— W

Summary of the content on the page No. 2

WELCOME TO TODAY’S GENERATION OF COMFORT Congratulations! Your new, higher efficiency gas furnace is a sound investment which will reward you and your family with years of warm memories winter after winter. Not only is your new furnace energy efficient, it is also extremely reliable. Spend just a few minutes with this booklet to learn about the operation of your new furnace—and the small amount of maintenance it takes to keep it operating at peak efficiency. Years went into t

Summary of the content on the page No. 3

DOWNFLOW/HORIZONTAL FURNACE COMPONENTS 1 1 Manual-Reset Auxiliary Limit Switch (When Used) 2 Blower and Blower Motor 2 3 Relief Box 4 Gas Valve Control Knob or Electric Switch (On/Off) 8 5 Gas Valve 9 6 Gas Burner 7 Rating Plate 3 8 Blower Door Safety Switch 9 Blocked Vent Safeguard Tube and Switch 10 4 10 Gas Manifold 11 5 11 Manual Reset Limit Switch (2) 6 12 Hot Surface Ignitor 13 Flame Sensor 7 12 13 4 many products around the home, such nace is left unattended for an

Summary of the content on the page No. 4

E S O L C safety-alert symbol. DANGER identi- • CHECK AIR FILTER: Before at- fies the most serious hazards which will tempting to start your furnace, be sure result in severe personal injury or the furnace filter is clean and in place. death. WARNING signifies hazards (See the maintenance section of this which could result in personal injury or manual.) Then proceed as follows: death. CAUTION is used to identify unsafe practices which would result in minor pers

Summary of the content on the page No. 5

ON ON OFF OFF N E P O O O F F F F O O F F F F 11. After 15 to 70 sec, the gas valve permits gas to flow to the main burners where it is ignited. Hot flames begin to warm the furnace’s heat exchanger. After a time delay of approximately 45 sec, the fur- nace blower is switched on. OR NOTE: If the main burners fail to ig- nite, the furnace control system will go through 3 more ignition cycles. Then, if burners fail to ignite, the system will lockout. If lockout occurs, or th

Summary of the content on the page No. 6

ON OFF O O F F F F furnace size with the proper filter size. 5. Turn the control knob or switch on PERFORMING ROUTINE the gas valve to the OFF position. MAINTENANCE ! CAUTION (See Fig. 22 or 23.) With the proper maintenance and care, Never operate your furnace your furnace will operate economically without a filter in place. Doing and dependably. Basic maintenance, ® so may damage the furnace which can easily be accomplished by blower motor. An accumula- someone who fol

Summary of the content on the page No. 7

3. Remove air filter from furnace. be required in some models. The pro- cedure listed above may be used to • AIR FILTER LOCATED IN AIR FILTER LOCATED IN FILTER CABINET remove side filters. BLOWER COMPARTMENT: FILTER CABINET FILTER SIZE a) Slide filter retainer sideways un- HEIGHT (IN) (IN.) FILTER TYPE til it is free of latch. (See Fig. 24) (1) 16 x 25 x 1* or Cleanable 16 (1) 16 x 25 x 4-5/16 Disposable b) Gently remove air filter and carefully turn the dirty side

Summary of the content on the page No. 8

connection area, and the vent pipe for rust. 29 NOTE: If dirt, rust, soot, or scale accu- mulations are found, call your servic- ing dealer. DO NOT OPERATE THE 34 FURNACE. 3. Inspect the vent pipe for a sag, holes, or a disconnection. A hori- 31 zontal vent pipe must slope up- ward. If rusty joints or seams, or signs of water leakages are found call your dealer for service. ! WARNING If holes are found—or if the vent pipe is obstructed or is not connected—toxic fumes can escape int

Summary of the content on the page No. 9

open? Does the lever point in the same will shut off the furnace. Reset the 4. Inspection, cleaning, and lubrica- direction that the pipe runs (open)? Or switch(es) by pushing the button on the tion (when required) of the blower is it at right angles (closed)? switch. If the switch trips a second motor and wheel. time, turn off the furnace and call for NOTE: Refer to the unit Service Proce- NOTE: Before proceeding with the service. dures for blower motor oiling informa- next checks, turn OFF

Summary of the content on the page No. 10

10

Summary of the content on the page No. 11

11

Summary of the content on the page No. 12

INSTALLATION DATA SPLIT-SYSTEM Date Installed OUTDOOR UNIT: Dealer Name Product No. Address Model No. City Serial No. State Zip INDOOR COIL: Telephone Product No. Model No. FURNACE Serial No. Product No. Model No. Serial No. Cancels: OM04-33 OM04-35 12 © 2000 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indpls., IN 46231 PRINTED IN U.S.A. Catalog No. 5337-309 10-00


Alternative user manuals
# User manual Category Download
1 Bryant 2-stage Deluxe Induced-Combustion 4-way Multipurpose 120 User manual Furnace 1
2 Bryant 312AAV/JAV User manual Furnace 8
3 Bryant 330AAV User manual Furnace 19
4 Bryant 331AAV User manual Furnace 1
5 Bryant 313AAV/JAV User manual Furnace 0
6 Bryant 312AAV User manual Furnace 0
7 Bryant 310 User manual Furnace 2
8 Bryant 313AAV User manual Furnace 0
9 Bryant 340MAV User manual Furnace 0
10 Bryant 330JAV User manual Furnace 1
11 Bryant 345MAV User manual Furnace 0
12 Bryant 310JAV User manual Furnace 2
13 Bryant 334S User manual Furnace 0
14 Bryant 349MAV User manual Furnace 1
15 Bryant 350MAV User manual Furnace 5
16 Adams Condensing Oil-Fired User manual Furnace 2
17 AirComm Corporation 10016 User manual Furnace 0
18 AirComm Corporation 7516 User manual Furnace 0
19 AirComm Corporation 50 User manual Furnace 0
20 Air King 9320 User manual Furnace 2