Bryant 350MAV user manual

User manual for the device Bryant 350MAV

Device: Bryant 350MAV
Category: Furnace
Manufacturer: Bryant
Size: 0.31 MB
Added : 5/15/2013
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bryant 350MAV. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bryant 350MAV.

For your convenience

If looking through the Bryant 350MAV user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bryant 350MAV on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bryant 350MAV to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bryant 350MAV User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bryant 350MAV but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bryant 350MAV. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


USER’S INFORMATION MANUAL
MODEL 340MAV, 350MAV, 352MAV,
355MAV CONDENSING GAS
FURNACE
USER: Please read all instructions in
NOTE TO INSTALLER:
the manual and retain all manuals for
This manual must be left with the equipment user.
future reference.
! WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any

Summary of the content on the page No. 2

Shutting Down Your Furnace. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 TABLE OF CONTENTS PERFORMING ROUTINE MAINTENANCE. . . . . . . . . . . . . . . . . . . . 6 WELCOME TO A NEW GENERATION OF COMFORT. . . . . . . . .2 Filtering Out Trouble. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 GENERAL FURNACE SAFETY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 COMBUSTION AREA A

Summary of the content on the page No. 3

FURNACE COMPONENTS 17 1 Combustion-air intake connection to ensure 2 contaminant-free air (right or left side). 3 1 2 Burner sight glass for viewing burner flame. 12 4 3 Burner assembly (inside). Operates with energy- 18 saving inshot burners and hot surface igniter for safe, dependable heating. 5 5 4 Redundant gas valve. Safe and efficient. Features 1 gas 11 14 control with 2 internal shutoff valves. Valve appearance varies with furnace model. 16 15 6 5 Vent outlet. Uses PVC pipe to

Summary of the content on the page No. 4

SAFETY BEFORE STARTING CONSIDERATIONS YOUR FURNACE Examine the furnace installation to Recognize safety information. This is determine that: the safety-alert symbol ! . When you see this symbol on the furnace and in 1. All flue gas carrying areas external instructions or manuals, be alert to the to the furnace (i.e. chimney, vent potential for personal injury. connector) are clear and free of obstructions. Understand the signal words DANGER, WARNING, CAUT

Summary of the content on the page No. 5

ON OFF ON OFF E S O L C the floor. If you smell gas, STOP! Follow “B” in the safety information above on this furnace label. If you don’t smell gas, go to the next step. or OR • If a suspected malfunction occurs with your gas control system, such as the burners not lighting when they should, refer to the shutdown proce- For 340MAV and 350MAV dures on inside of main furnace door, or in the “Shutting Down Your Fur- 13 nace” section and call your dealer as soon as possib

Summary of the content on the page No. 6

ON OFF N E P O necessary adjustments to operate When room temperature drops 20 the blower at either the low- or below the temperature selected 2. Close the external manual gas high-heat speed. on the thermostat, the furnace valve. (See Fig. 9.) will be switched on automatically. 3. Turn off electrical supply to the When room temperature reaches furnace. (See Fig. 20.) the temperature selected on the 4. Remove main furnace door. thermostat, the furnace will be (See

Summary of the content on the page No. 7

of airflow occurs, the furnace may cycle Installing and servicing of heating on its safety controls. If this condition is equipment can be hazardous due to left unattended, the furnace will eventu- gas and electrical components. ally lock out. It is recommended that the Only trained and qualified personnel furnace air filter be checked every 3 or 4 should install, repair, or service heat- weeks and cleaned if necessary. ing equipment. Untrained personnel If installed with factory-specifi

Summary of the content on the page No. 8

direction arrow pointing towards blower. b. Electronic air cleaner (EAC) – Refer to EAC owner’s Manual for maintenance information. 34 31 5. If washable filter, wash filter (if dirty) in sink, bathtub, or outside with a garden hose. Always use 27 cold tap water. A mild liquid deter- gent may be used if necessary. Spray water through filter in the opposite direction of airflow. Allow filter to dry. 6. Reinstall clean air filter. 7. Reinstall filter retainer (for blower compartment locations on

Summary of the content on the page No. 9

When dirt, soot, scale, or rust is FURNACE AIR FILTER allowed to build up, your furnace can TABLE suffer a loss of efficiency and perform AIR FILTER LOCATED IN BLOWER COMPARTMENT improperly. Accumulations on the FILTER SIZE FURNACE main burners can result in firing out of (IN.) CASING normal sequence. This delayed igni- WIDTH *Side Bottom FILTER (IN.) Return† Return TYPE tion creates an alarmingly loud sound. 17-1/2 (1) 16 x (1) 16 x Cleanable 25 x 1* 25 x 1* ! CAUTION 21 (1) 16 x (1) 20

Summary of the content on the page No. 10

transfer process. Therefore, once it • Inspect and clean the blower motor has been operated, it cannot be turned and wheel. off and left off for an extended period NOTE: The inducer and blower motors of time when temperatures will reach are pre-lubricated and require no addi- 32°F or lower unless winterized. Fol- tional lubrication. These motors can be low these procedures to winterize your identified by the absence of oil ports on furnace: each end of the motor. 1. Obtain propylene glycol

Summary of the content on the page No. 11

Ensure they are open and unobstructed. NOTE: Turn off electrical supply vent termination outside the structure. before continuing with checklist. If problem still exists, call your dealer If your furnace still fails to operate, call for service. your service representative. • Is control switch on gas valve in ON position? (Follow start-up procedures For your convenience, record the fur- IF FURNACE FAILS TO OPERATE: if you must reset switch to ON posi- nace product and serial numbers on Follow

Summary of the content on the page No. 12

INSTALLATION DATA AIR CONDITIONER OR HEAT PUMP Date Installed OUTDOOR UNIT: Dealer Name Product No. Address Model No. City Serial No. State Zip INDOOR COIL: Telephone Product No. FURNACE Model No. Product No. Serial No. Model No. Serial No. Cancels: OM05-39 OM05-42 © 2003 Bryant Heating & Cooling Systems, 7310 W. Morris St., Indpls., IN 46231 12 Printed in U.S.A. Catalog No. 5334-017 10-03


Alternative user manuals
# User manual Category Download
1 Bryant 2-stage Deluxe Induced-Combustion 4-way Multipurpose 120 User manual Furnace 1
2 Bryant 312AAV/JAV User manual Furnace 8
3 Bryant 330AAV User manual Furnace 19
4 Bryant 331AAV User manual Furnace 1
5 Bryant 313AAV/JAV User manual Furnace 0
6 Bryant 312AAV User manual Furnace 0
7 Bryant 310 User manual Furnace 2
8 Bryant 313AAV User manual Furnace 0
9 Bryant 340MAV User manual Furnace 0
10 Bryant 330JAV User manual Furnace 1
11 Bryant 345MAV User manual Furnace 0
12 Bryant 310JAV User manual Furnace 2
13 Bryant 334S User manual Furnace 0
14 Bryant 349MAV User manual Furnace 1
15 Bryant 362AAN User manual Furnace 0
16 Adams Condensing Oil-Fired User manual Furnace 2
17 AirComm Corporation 10016 User manual Furnace 0
18 AirComm Corporation 7516 User manual Furnace 0
19 AirComm Corporation 50 User manual Furnace 0
20 Air King 9320 User manual Furnace 2