White Rodgers 668 user manual

User manual for the device White Rodgers 668

Device: White Rodgers 668
Category: Burner
Manufacturer: White Rodgers
Size: 0.13 MB
Added : 1/4/2014
Number of pages: 6
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for White Rodgers 668. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with White Rodgers 668.

For your convenience

If looking through the White Rodgers 668 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual White Rodgers 668 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual White Rodgers 668 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
White Rodgers 668 User manual - Online PDF
Advertisement
« Page 1 of 6 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual White Rodgers 668 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to White Rodgers 668. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

TYPE 668
Intermittent Ignition* – Non Recycling
OIL BURNER CONTROL
WHITE-RODGERS
With Series 956 Flame Detector
INSTALLATION INSTRUCTIONS
Operator: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
The type 668 Oil Burner Control provides safe operation
of oil burners on heating plants where ignition during the
entire burner cycle is desired.
Th

Summary of the content on the page No. 2

INSTALLATION AND WIRING CONT. All wiring should be done in accordance with local and national electrical codes and ordinances. LOW VOLTAGE PRIMARY CONTROL LINE VOLTAGE PRIMARY CONTROL PRIMARY PRIMARY CONTROL CONTROL THERMOSTAT FLAME FLAME DETECTOR DETECTOR FIELD INSTALLED ORANGE BLACK WIRE ORANGE BLACK WIRE JUMPER WHITE NUTS WHITE NUTS IGN. IGN. TRANS. TRANS. T LIMIT TF T F TFF LIMIT LINE VOLTAGE LINE THERMOSTAT OR LINE OPERATING BURNER HOT N BURNER CONTROL HOT N MOTOR MOTOR External Line Vol

Summary of the content on the page No. 3

TESTING CONT. d. If resistance of flame detector is over 1000 ohms, it may PART No. OF REPLACEMENT PART not be able to see the burner flame properly. Check F142-0006 Cell only (Old Style) alignment of the flame detector through the hole in the static pressure disc. Clean this hole if it is blocked by foreign matter. Check for broken “F” wires. 4. If safety lockout problem is of an occasional nature e. If flame detector alignment is good but resistance is still the following additional check may

Summary of the content on the page No. 4

COMMANDE DE BRÛLEUR À MAZOUT à allumage intermittent et sans remise en route WHITE-RODGERS MODÈLE 668 avec détecteur de flamme Série 956 Utilisateur : conservez ces instructions pour vous y référer au besoin ! SI VOUS NE LISEZ PAS ATTENTIVEMENT CES INSTRUCTIONS AVANT D’INSTALLER ET D’UTILISER LA COMMANDE, VOUS RISQUEZ DE CAUSER DES BLESSURES ET DES DOMMAGES MATÉRIELS. DESCRIPTION La commande de brûleur à mazout modèle 668 assure le fonctionnement sécuritaire des brûleurs d’installations de chauf

Summary of the content on the page No. 5

INSTALLATION ET CÂBLAGE (SUITE) Tout le câblage doit être conforme aux codes et règlements locaux et nationaux qui régissent les installations électriques. COMMANDE PRINCIPALE À LA TENSION DU RÉSEAU COMMANDE PRINCIPALE À LA TENSION DU RÉSEAU COMMANDE COMMANDE PRINCIPALE PRINCIPALE THERMOSTAT DÉTECTEUR DÉTECTEUR DE FLAMME DE FLAMME CAVALIER INSTALLÉ ORANGE NOIR ORANGE MARRETTES SUR PLACE NOIR MARRETTES BLANC BLANC TRANSFO TRANSFO D’ALLUMAGE D’ALLUMAGE TF T F LIMITEUR TF T F LIMITEUR THERMOSTAT OU

Summary of the content on the page No. 6

ESSAIS (SUITE) d. Si la résistance du détecteur dépasse 1000 ohms, il NOS DES PIÈCES DE RECHANGE est possible que celui-ci ne détecte pas très bien la flamme du brûleur. Vérifiez son alignement à travers F142-0006 Détecteur deul (ancien modèle) le trou du disque de pression statique. Si ce trou est obstrué, nettoyez-le. Assurez-vous que les fils 4. Si le problème lié au blocage de sécurité n’est branchés sur le bornes F sont en bon état. qu’occasionnel, procédez à l’essai suivant pour vous e. Si


Alternative user manuals
# User manual Category Download
1 White Rodgers 668-430 User manual Burner 1
2 White Rodgers 668-451 User manual Burner 1
3 Adams Speedflame Power Gas User manual Burner 3
4 Adams Mark 10 User manual Burner 1
5 AEG 3531 WK-M GB 949600835 User manual Burner 4
6 APW GHP-2H User manual Burner 3
7 APW GHPW-2H User manual Burner 2
8 APW GHP-4H User manual Burner 1
9 Bacharach MZF User manual Burner 2
10 Beckett 800 User manual Burner 10
11 Beckett AFII 100 User manual Burner 11
12 Beckett CF375 User manual Burner 8
13 Beckett AFG 240V User manual Burner 12
14 Beckett AFG User manual Burner 28
15 Beckett 150 User manual Burner 0