Beckett BRYAN STEAM CF500 user manual

User manual for the device Beckett BRYAN STEAM CF500

Device: Beckett BRYAN STEAM CF500
Category: Burner
Manufacturer: Beckett
Size: 1.21 MB
Added : 11/18/2013
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Beckett BRYAN STEAM CF500. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Beckett BRYAN STEAM CF500.

For your convenience

If looking through the Beckett BRYAN STEAM CF500 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Beckett BRYAN STEAM CF500 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Beckett BRYAN STEAM CF500 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Beckett BRYAN STEAM CF500 User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Beckett BRYAN STEAM CF500 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Beckett BRYAN STEAM CF500. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Potential for Fire, Smoke and Asphyxiation Hazards
WARNING
!
Incorrect installation, adjustment, or misuse of this burner could result in death, severe
personal injury, or substantial property damage.
To the Professional, Qualifi ed Installer
To the Homeowner or Equipment
or Service Agency:
Owner:
Please read and carefully follow all instructions provided
Please read and carefully follow all instructions
in this manual before installing, starting, or servicing this
provided in this manu

Summary of the content on the page No. 2

Table of Contents Before you begin . . . The following resources will give you additional General Information ..............................................2-4 information for your installation. We suggest that Hazard Defi nitions ..........................................................3 you consult these resources whenever possible. Pay Agency approvals ..........................................................3 particular attention to the appliance manufacturer’s Specifi cations ......

Summary of the content on the page No. 3

Specifi cations Hazard defi nitions U.S. #1 or #2 Fuel Oil only (ASTM D396) Indicates an imminently Fuels Canada #1 Stove Oil or #2 hazardous situation, Furnace Oil only which, if not avoided, will result in death, CF500: 1.75 to 5.50 GPH serious injury, or property damage. Firing range CF800: 3.00 to 8.00 GPH 1/3 HP 3450 RPM Motor 120/60 hz standard Indicates a potentially 4.8 amps @ 120 VAC hazardous situation, Igniter. 120V/14,000V which, if not avoided, could result in death, Housi

Summary of the content on the page No. 4

Owner’s Responsibility: Professional Installer/Service Agency Responsibility: Follow These Instructions Exactly Follow These Failure to follow these instructions, Instructions Exactly misuse, or incorrect adjustment of Failure to follow these instructions the burner could lead to equipment could lead to equipment malfunc- malfunction and result in asphyxia- tion and result in asphyxiation, tion, explosion or fi re. explosion or fi re. Contact a professional, qualifi ed service agency for the

Summary of the content on the page No. 5

Fuel supply Nozzle pressure Oil Supply Pressure Correct Nozzle and Flow Control Required Rate Required Damage to the pump, fi lter or other compo- Incorrect nozzles and fl ow rates could nent seals could cause possible oil leakage result in impaired combustion, under- and potential fi re hazard. fi ring, over-fi ring, sooting, puff-back The oil supply inlet pressure to the fuel unit cannot of hot gases, smoke and potential fi re exceed 3 psig. or asphyxiation hazards. Do NOT install valve

Summary of the content on the page No. 6

Verify fi ring rate Table 1 - Nozzle Capacities Refer to appliance manufacturer’s instructions (if Rated gph @ Pressure - Pounds per available) for fi ring rate and nozzle selection. Otherwise, 100 psig square inch the maximum recommended fi ring rate for the burner 140 150 depends on the length of the fi ring chamber and the 1.75 2.07 2.14 distance from the burner center to the chamber fl oor. Verify that the chamber dimensions are at least as large 2.00 2.37 2.45 as the minimum values giv

Summary of the content on the page No. 7

Table 2 - Air tube capacities vs fi rebox pressure Mount the burner CF500 CF800 CF500 CF800 Protect the Air Tube From Firebox Tube Tube Tube Tube Tube Tube Overheating pressure KK KH KJ KK KH KJ (in w.c.) Overheating could cause damage to the air No reserve air 10% Turndown tube and other combustion components lead- 0.0” 5.50 7.00 8.00 4.95 6.30 7.20 ing to equipment malfunction and impaired 0.1” 4.75 6.25 7.50 4.27 5.62 6.75 combustion performance. 0.2” 4.00 5.50 6.75 3.60 4.9

Summary of the content on the page No. 8

Mount air tube to burner Figure 6 - Nozzle line assembly in burner Insert the air tube into the burner housing. Carefully align the the four screw holes. Attach the air tube to the burner using the four provided screws. CF500 1-9/16” Install nozzle Install the oil nozzle in the nozzle adapter. Use a 3/4” CF800 open-end wrench to steady the nozzle adapter and a 5/8” 1-3/4” open-end wrench to turn the nozzle. Tighten securely but do not over-tighten. Check electrode settings Maintain

Summary of the content on the page No. 9

Fuel unit by-pass plug Table 3. Fuel Unit gearset capacity Fuel unit model number Gearset capacity (GPH) Do Not Install By-pass 17 A2VA-7116 Plug with 1-Pipe System 20 A2YA-7916 Failure to comply could cause immediate pump B2VA-8216 21 seal failure, pressurized oil leakage and the po- B2YA-8916 25 tential for a fi re and injury hazard. 21 B2TA-8248 The burner is shipped without the by-pass plug in- stalled. for the fi ring rate for one-pipe systems. Locate the fi lter Intall the by-pass plu

Summary of the content on the page No. 10

Wire the burner — R7184 Sequence of operation — typical Electrical Shock Hazard 1. Standby -- The burner is idle, waiting for a call for heat. When a call for heat is initiated, there is a 3- to 10-second Electrical shock can cause severe personal in- delay while the control performs a safe start check. jury or death. Disconnect electrical power before installing or servic- 2. Valve-on delay — As applicable, the ignition and motor are ing the burner. turned on for a 15-second prepurge.

Summary of the content on the page No. 11

Prepare the burner for start-up Oil nozzle has been selected correctly and securely Professional Installation installed in the nozzle adapter. and Service Required Fuel unit by-pass plug has not been installed for one- Incorrect installation and mishandling of start- pipe oil system. up could lead to equipment malfunction and re- sult in asphyxiation, explosion or fi re. By-pass plug has been installed for two-pipe oil This burner must be installed and prepared for start-up sy

Summary of the content on the page No. 12

Table 5 - Initial air shutter and band settings Start the Burner Approximate air settings Explosion and Fire Rate CF800 GPH Hazard CF500 Tube A Tube B Failure to follow these instructions Shutter Band Shutter Band Shutter Band could lead to equipment malfunction 1.75 1 0 -- -- -- -- and result in heavy smoke emission, 2.25 2 0 -- -- -- -- soot-up, hot gas puff-back, fi re and 3.00 10 1 1 0 -- -- asphyxiation hazards. Do not attempt to start the burner when excess oil has 3.50 10 2 3 0 --

Summary of the content on the page No. 13

the control will lock out. Press the reset button to reset the Step 1: Adjust the air shutter/band until a trace of smoke control and return to the functions listed in the previous is achieved. step. Step 2: At the trace of smoke level, measure the CO 2 Repeat the previous steps if needed, until the pump is (or O ) . This is the vital reference point for further 2 fully primed and the oil is free of bubbles. Then terminate adjustments. Example: 13.5% CO (2.6% O ) 2 2 the call for heat

Summary of the content on the page No. 14

Maintenance and Service Check all wiring for secure connections or insulation Annual Professional breaks. Service Required Check the pump pressure and cutoff function. Check primary control safety lockout timing. Tampering with or making incorrect Check ignition system for proper operation. adjustments could lead to equip- Inspect the vent system and chimney for soot accumula- ment malfunction and result in tion or other restriction. asphyxiation, explosion or fi re. Clean the appliance

Summary of the content on the page No. 15

Replacement parts 6 5 2 3 1 4 10 9 8 7 Item Part Name/Description Part Number 1 Air Tube Specify 12 2 Spline Nut 3666 11 3 Adjusting plate assembly 51286U 4 Blocking Oil Solenoid Valve 2182602U 5Igniter 51771U 6 Control Specify 13 7 Air Band 3819 8 Air Shutter 3215 9 Fuel Pump Specify 10 Fuel lines Specify Lengths Head Assembly: CF500 - KK 51401U 11 CF800 - KH (Tube A) 51252P CF800 - KJ (Tube B) 51302P 15 12 Electrode Assembly Specify 14 13 Nozzle Line Assembly Specify 14

Summary of the content on the page No. 16

Limited Warranty Information Limited WARRANTY For Residential, Commercial and Specialty Burners The R. W. BECKETT CORPORATION (“Beckett”) warrants to persons who purchase its Beckett burners from Beckett for resale or for incorporation into a product for resale (“Customers”) that its equipment is free from defects in material and workmanship under normal use and service for 60 months from the date of manufacture for Residential Burners and 18 months from the date of manufacture for Commercial


Alternative user manuals
# User manual Category Download
1 Beckett 800 User manual Burner 10
2 Beckett AFII 100 User manual Burner 11
3 Beckett CF375 User manual Burner 8
4 Beckett AFG 240V User manual Burner 12
5 Beckett AFG User manual Burner 28
6 Beckett 150 User manual Burner 0
7 Beckett CF800 User manual Burner 15
8 Beckett AFII 85 User manual Burner 11
9 Beckett AFII User manual Burner 1
10 Beckett BRYAN STEAM CF2500A User manual Burner 1
11 Beckett CF 2500/ 3500 User manual Burner 2
12 Beckett CF3500 User manual Burner 2
13 Beckett BRYAN STEAM CF2300A User manual Burner 1
14 Beckett CF2500 User manual Burner 3
15 Beckett BRYAN STEAM CF375 User manual Burner 1
16 Adams Speedflame Power Gas User manual Burner 3
17 Adams Mark 10 User manual Burner 1
18 AEG 3531 WK-M GB 949600835 User manual Burner 4
19 APW GHP-2H User manual Burner 3
20 APW GHPW-2H User manual Burner 2