Beckett CF800 user manual

User manual for the device Beckett CF800

Device: Beckett CF800
Category: Burner
Manufacturer: Beckett
Size: 1.27 MB
Added : 11/18/2013
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Beckett CF800. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Beckett CF800.

For your convenience

If looking through the Beckett CF800 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Beckett CF800 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Beckett CF800 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Beckett CF800 User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Beckett CF800 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Beckett CF800. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Potential for Fire, Smoke and Asphyxiation Hazards
WARNING
!
Incorrect installation, adjustment, or misuse of this burner could result in death, severe
personal injury, or substantial property damage.
To the Professional, Qualifi ed Installer
To the Homeowner or Equipment
or Service Agency:
Owner:
Please read and carefully follow all instructions provided
Please read and carefully follow all instructions
in this manual before installing, starting, or servicing this
provided in this manu

Summary of the content on the page No. 2

Before you begin . . . The following resources will give you addional information for your installation. We suggest that you consult these resources whenever possible. Pay particular attention to the appliance manufacturer’s instructions. Appliance manufacturer’s instructions -Always follow the appliance manufacturer’s instructions for burner installation, equipment and set-up. 1–800–OIL–BURN - Beckett’s technical services hot-line. www.beckettcorp.com - Beckett’s website. Table of Contents G

Summary of the content on the page No. 3

Within the boundaries of the hazard warning, there will To the Owner: be information presented describing consequences if the warning is not heeded and instructions on how to avoid Thank you for purchasing a Beckett burner for the hazard. use with your heating appliance. Please pay attention to the Safety Warnings contained within this instruc- tion manual. Keep this manual for your records and provide it to your qualifi ed service agency for use in Agency approvals professionally setti

Summary of the content on the page No. 4

Owner’s Responsibility: NOTICE High altitude installations — Accepted industry practice Follow These requires no derate of burner capacity up to 2,000 feet above Instructions Exactly sea level. For altitudes higher than 2,000 feet, derate burner Failure to follow these instructions, capacity 2% for each 1000 feet above sea level. misuse, or incorrect adjustment of the burner could lead to equipment Pre-installation check- malfunction and result in asphyxia- tion, explosion or fi re. list Co

Summary of the content on the page No. 5

Combustion air supply Nozzle pressure The burner requires combustion air and ventilation air for Correct Nozzle and Flow reliable operation. Assure that the building and/or com- bustion air openings comply with National Fire Protec- Rate Required tion Standard for Oil-Burning Equipment, NFPA 31. For Incorrect nozzles and fl ow rates appliance/burner units in confi ned spaces, the room must could result in impaired combustion, have an air opening near the top of the room plus one near und

Summary of the content on the page No. 6

Table 1 - Nozzle Capacities Verify air tube Rated gph @ Pressure - Pounds per 100 psig square inch The information in this section may be disregarded if the air tube is supplied by the appliance manufacturer. 140 150 1.75 2.07 2.14 Two tube arrangements are available – 2.00 2.37 2.45 CF500 1.75 to 5.50 GPH 2.25 2.66 2.74 CF800 Tube A — 3.00 to 7.00 GPH 2.50 2.96 3.06 Tube B — 5.00 to 8.00 GPH 2.75 3.24 3.37 3.00 3.55 3.68 Maximum fi ring capacity depends on the fi rebox pressure. 3

Summary of the content on the page No. 7

Mount the burner Table 2 - Air tube capacities vs fi rebox pressure Protect the Air Tube From Overheating CF500 CF800 Firebox Overheating could cause damage to the air pressure tube and other combustion components lead- Tube KK Tube KH Tube KJ (in w.c.) ing to equipment malfunction and impaired No reserve air combustion performance. 0.0” 5.50 7.00 8.00 The end of the air tube must not extend into the com- 0.1” 4.75 6.25 7.50 bustion chamber unprotected unless it has been facto-

Summary of the content on the page No. 8

Mount air tube to burner Figure 5 - Nozzle line assembly in burner Insert the air tube into the burner housing. Carefully align the the four screw holes. Attach the air tube to the burner using the four provided screws. CF500 1-9/16” Install nozzle Install the oil nozzle in the nozzle adapter. Use a 3/4” CF800 open-end wrench to steady the nozzle adapter and a 5/8” 1-3/4” open-end wrench to turn the nozzle. Tighten securely but do not over-tighten. Check electrode settings Maintain

Summary of the content on the page No. 9

Fuel unit by-pass plug Table 3. Fuel Unit gearset capacity Do Not Install By-pass Fuel unit model number Gearset capacity (GPH) Plug with 1-Pipe System 17 A2VA-7116 Failure to comply could cause immediate pump 20 A2YA-7916 seal failure, pressurized oil leakage and the po- B2VA-8216 21 tential for a fi re and injury hazard. B2YA-8916 25 The burner is shipped without the by-pass plug in- 21 B2TA-8248 stalled. Intall the by-pass plug in two-pipe oil supply systems for the fi ring rate for one

Summary of the content on the page No. 10

Wire the burner — R7184 Prepare the burner for Electrical Shock Hazard start-up Electrical shock can cause severe personal in- Professional Installation jury or death. and Service Required Disconnect electrical power before installing or servic- ing the burner. Incorrect installation and mishandling of start- Provide ground wiring to the burner, metal control en- up could lead to equipment malfunction and re- closures and accessories. (This may also be required to sult in asphyxiation, expl

Summary of the content on the page No. 11

Start-up checklist Set appliance limit controls Combustion air supply and venting have been inspected and verifi ed to be free of obstructions and installed in ac- Set the appliance limit controls in accordance with the cordance with all applicable codes. appliance manufacturer’s recommendations. Oil nozzle has been selected correctly and securely in- Prepare the fuel unit for air venting stalled in the nozzle adapter. Fuel unit by-pass plug has not been installed for one- To vent air f

Summary of the content on the page No. 12

Repeat the previous steps if needed, until the pump is Start the Burner fully primed and the oil is free of bubbles. Then ter- minate the call for heat, and the control will resume normal operation. Explosion and Fire Hazard Resetting from restricted lockout Failure to follow these instructions If the control locks out three times in a row without a could lead to equipment malfunction complete heat cycle between attempts, the lockout be- and result in heavy smoke emission, c

Summary of the content on the page No. 13

Set combustion using instruments Sequence of 1. Allow the burner to run for approximately 5 to 10 min- operation — typical utes. 2. Set the stack or over-fi re draft to the level specifi ed by 1. Standby — The burner is idle, waiting for a call for the appliance manufacturer. heat. When a call for heat is initiated, there is a 3- to Natural Draft Applications; typically over-fi re draft 10-second delay while the control performs a safe start is -0.01” or -0.02” w.c. check. Direct Ve

Summary of the content on the page No. 14

Check motor current. The amp draw should not exceed the Maintenance and nameplate rating. Check all wiring for secure connections or insulation Service breaks. Check the pump pressure and cutoff function. Annual Professional Check primary control safety lockout timing. Service Required Check ignition system for proper operation. Tampering with or making incorrect Inspect the vent system and chimney for soot accumula- adjustments could lead to equip- tion or other restriction. Clean t

Summary of the content on the page No. 15

Replacement parts 6 5 2 3 1 4 10 9 8 7 Item Part Name/Description Part Number 1 Air Tube Specify 12 2 Spline Nut 3666 11 3 Adjusting plate assembly 51286U 4 Blocking Oil Solenoid Valve 2182602U 5Igniter 51771U 6 Control Specify 13 7 Air Band 3819 8 Air Shutter 3215 9 Fuel Pump Specify 10 Fuel lines Specify Lengths Head Assembly: CF500 - KK 51401U 11 CF800 - KH (Tube A) 51252P CF800 - KJ (Tube B) 51302P 15 12 Electrode Assembly Specify 14 13 Nozzle Line Assembly Specify 14

Summary of the content on the page No. 16

Limited Warranty Information Limited WARRANTY For Residential, Commercial and Specialty Burners The R. W. BECKETT CORPORATION (“Beckett”) warrants to persons who purchase its Beckett burners from Beckett for resale or for incorporation into a product for resale (“Customers”) that its equipment is free from defects in material and workmanship under normal use and service for 60 months from the date of manufacture for Residential Burners and 18 months from the date of manufacture for Commercial


Alternative user manuals
# User manual Category Download
1 Beckett 800 User manual Burner 10
2 Beckett AFII 100 User manual Burner 11
3 Beckett CF375 User manual Burner 8
4 Beckett AFG 240V User manual Burner 12
5 Beckett AFG User manual Burner 28
6 Beckett 150 User manual Burner 0
7 Beckett AFII 85 User manual Burner 11
8 Beckett AFII User manual Burner 1
9 Beckett BRYAN STEAM CF2500A User manual Burner 1
10 Beckett CF 2500/ 3500 User manual Burner 2
11 Beckett BRYAN STEAM CF500 User manual Burner 1
12 Beckett CF3500 User manual Burner 2
13 Beckett BRYAN STEAM CF2300A User manual Burner 1
14 Beckett CF2500 User manual Burner 3
15 Beckett BRYAN STEAM CF375 User manual Burner 1
16 Adams Speedflame Power Gas User manual Burner 3
17 Adams Mark 10 User manual Burner 1
18 AEG 3531 WK-M GB 949600835 User manual Burner 4
19 APW GHP-2H User manual Burner 3
20 APW GHPW-2H User manual Burner 2